Henkel KF-100A Corrective Maintenance, Changing the Heating Elements, Changing the Thermostat

Page 6

Corrective Maintenance

CHANGING THE HEATING ELEMENTS

1.Disconnect power source and empty oven of flux.

2.Remove element cover and leads from elements (Note: power cord strain relief may have to be removed to gain clearance.)

3.From interior of oven, remove elements from clips and pull elements free of hopper wall.

4.Replace new elements and electrical leads being sure terminals are not shorted to oven body. Replace element cover.

CHANGING THE THERMOSTAT

1.Disconnect from the power source.

2.Remove element cover (Note: power cord strain relief may have to be removed to gain clearance).

3.Remove electrical leads from thermostat and remove thermostat from mounting bolt.

4.Replace and rewire new thermostat being sure terminals are not shorted to oven body. Do not over tighten elements mounting bolt.

KF –100A 120V / 500W Wiring Diagram

KF –100A 240V / 500W Wiring Diagram

Image 6
Contents Henkel, Inc Box Hammond, LA 70404 985 Model KF-100A Flux Holding Oven Specifications One Year Limited WarrantyHenkel, Inc Safety Precautions General InformationGuide to Storage Temperature SettingOperation Functional DescriptionIf Oven Heats but Fails to Reach Temperature TroubleshootingScheduled Maintenance If Oven Fails to Operate no HeatCorrective Maintenance Changing the Heating ElementsChanging the Thermostat Model KF-100A Repair Parts List Quantity Description Part NumberHENKEL, INC