Hatco FR2 Series manual Installation, Plumbing

Page 7

INSTALLATION

PLUMBING

An adhesive backed paper template is shipped with the unit and is used to locate the sink strainer holes. Use the following procedure to install

the heater unit to the holding vessel.

NOTE: The FR2 heater should be positioned with no more than 3' (914 mm) on either side when mounted under holding vessel. See Figure 4. A perforated water baffle (not supplied with unit) must be used to distribute the heated

water properly.

NOTE: Use one FR2 for a Hot Food Table up to 6' (1829 mm) long. Over 6' (1829 mm) minimum 2 units required.

CAUTION

Do not use extension pipes on the inlet

and outlet connections on heater units. Poor performance or unsafe conditions may occur.

1.Expose the adhesive back of the paper template and stick the template on the bottom of the holding vessel. Center the template with the words “Front Cover” positioned against the front inside wall of the vessel.

2.Center punch and drill a 3/4" (19 mm) pilot hole at each of the two center marks on the template.

3.Remove the template and cut a 2" (51 mm) diameter hole at each pilot hole location using a standard #ATV1756 Greenlee cutter.

NOTE: If a #ATV1756 Greenlee cutter is not available, use a standard Greenlee 1-1/2" conduit cutter #500-6978, which is slightly under 2"

(51 mm) diameter. File or ream holes as necessary to 2" (51 mm) diameter required for mounting sink strainers.

4.See Figure 5. In each of the holes, install

a male threaded sink strainer with a thin gasket between the strainer flange and the bottom

of the holding vessel.

5.Install two thick gaskets at the underside of the holding vessel along with a thin fiber gasket, and secure finger tight with the nut.

6.Attach the heater to the strainers loosely with the union nuts and 1-3/4" (45 mm) rubber gaskets.

NOTE: Make sure rubber gaskets are positioned inside the union nuts and are not crimped.

3/4" (19 mm) holes

 

 

 

3'

 

 

 

 

 

3'

 

 

 

 

 

 

 

 

 

 

around periphery on

 

(914 mm)

 

 

(914 mm)

6" (152 mm) centers

 

 

MAX

 

 

 

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dotted line

3/4" (19 mm) high baffle

indicates the position of

with divider wall between

perforated water baffle

inlet and outlet

Figure 4. Hydro-Heater Water Baffle

Thin rubber washer

Sink or tank

1/8" (3 mm)

 

offset

 

 

3" (76 mm)

 

 

Thin fiber

 

Thick rubber

washer

Nut

washers

 

(Qty. 2)

 

 

 

Union Gasket

 

Union nut

Figure 5. Installing Sink Strainer

7.Tighten nuts on strainers securely.

8.Tighten union nuts securely.

9.Fill the holding vessel with water and check for leaks.

CAUTION

Do not overtighten unions or nuts.

Overtightening may cause leaks.

NOTE: A 3/4" (19 mm) hose or pipe may be connected to the heater sump drain and run to an open sight drain. The sump drain should not be permanently connected to the sanitary drain system. Check local plumbing code for proper drain installation. See MAINTENANCE for more information.

5

Form No. FR2M-0604

Image 7
Contents HYDRO-HEATER Important Owner Information ContentsIntroduction Important Safety Instructions ALL Models Units with BUILT-IN Temperature ControlUnits with Remote Temperature Control Model DescriptionsCircuit Breaker SpecificationsKilowatts Wire Sizing Fuse or Model Phase AmpsSizing Information DimensionsElectrical Plumbing InstallationAUTO-FILL Operation START-UP ProceduresMinutes to Heat Table Temperature F C Water Heated To Start-UpWater Cm Deep Water 750 Watts PER Square Foot of Vessel TOP Helpful Hints MaintenanceDraining & Cleaning ALL Models GeneralWeekly See Figure Deliming InstructionsMaintenance Product Warranty Hatco Limited WarrantyForm No. FR2M-0604 Hatco Authorized Parts Distributors