OPERATION
WARNINGS
Hatco FR2 series units are designed for commercial use only by properly trained personnel!
WARNINGS
Units are designed to heat water up to 190ºF (88ºC). To avoid any injury or damage DO NOT set temperature controls to a setting higher than 190ºF (88ºC).
CAUTION
Water in the unit and holding vessel is very hot. Wear protective gloves and proper attire when operating to avoid injury.
CAUTION
Do not turn the electrical current to the unit on until the holding vessel has been filled with water or element burnout may occur.
START-UP PROCEDURES
1.Make sure
2.Close sump drain by moving handle all of the way forward until it stops. See Figure 6.
3.Fill the holding vessel with hot tap water to normal operating level.
4.Check that the fused disconnect switch or circuit breaker is on, or if equipped with power cord and plug make sure unit is plugged into proper receptacle.
5.Turn power switch to ON position.
The electronic display will glow to indicate power is supplied.
6.To set the controller to the desired temperature press “Set” button once; unit will display “SP1.” See Figure 7.
7.Press “Set” button again; unit displays current setpoint.
OUTLET INLET
Power Switch
Sump Drain Handle | Sump Drain Outlet |
(Closed) |
Figure 6. Hydro-Heater Side View
Figure 7. Controller
8.Press “Up” or “Down” arrow to change and display desired setpoint.
9.Press “Set” button again until display goes blank. After 5 seconds unit will display current operating temperature.
NOTE: If steps
go back to its original setting without accepting the change.
7 | Form No. |