Valco electronic Valve Oven manual Connecting Gas Lines from the Solenoid Valve o the Actuator

Page 25

 

Chapter 2

Installing Valves in the Heated Oven

Valve Installation

3.Grip the valve standoff by the standoff only, and slide it through the collar allowing it to extend into the lower valve compartment.

Step 4. Connecting Gas Lines from the Solenoid Valve o the Actuator

NOTE Gas lines are much easier to connect to the actuator if the connection is made before the actuator is assembled to the valve.

1.Locate the 1/8 in. nylon tubing supplied in the Valve Oven kit and cut it into two equal 12” pieces.

2.Push one of the tube pieces into the lower fitting on the actuator assembly, making sure it passes through the ferrule in the actuator fitting. Tighten the nut and ferrule using a 3/8” open end wrench. Use a backup 3/8” open end wrench on the mating piece that is screwed into the actuator.

3.Place the other end of the tubing into the valve solenoid fitting located on the outside edge (Figure 2-4) of the solenoid by pushing the tubing firmly into the fitting. It should automatically seal in place.

1

2

1. Inside Edge Solenoids

2. Outside Edge Solenoids

Figure 2-4.Solenoid Manifold Edges

4. Turn the actuator gas supply on. This line should now be pressurized.

Operating Manual

25

Image 25
Contents Operating Manual Disclaimer Contents Customer Communication Appendix aOverview About This ManualBold Conventions Used in This ManualInstrument Markings and Symbols Equipment protected throughout by Double Site Preparation and Installation Manual PN 317 091 Using the Trace GC Ultra Document SetMaintenance and Troubleshooting Guide PN 317 091 Valve Oven Overview Valve Oven IntroductionTrace GC Ultra Valve Oven OptionsMaterials needed Installation and Power RequirementsPower Requirements and Voltage Selection Trace GC Ultra Valve Oven Components Valve Oven ComponentsUnheated Section Heated SectionValves ColumnValve Oven Overview Valve Installation Opening the Valve Oven Installing the Solenoid Valves Installing Valves in the Heated Oven Valve Installation Installing Valves in the Heated Oven Timed Event TE Output Jacks Disassembling the Valve and ActuatorMechanical Stop Positions for both CW and CCW Installing the Valve and StandoffSolenoid Manifold Edges Connecting Gas Lines from the Solenoid Valve o the ActuatorInstalling the Actuator to the Valve Standoff Installing the actuator to the valve standoff Testing the ValveInstalling the Mounting Bracket Installing Valves in the Unheated CompartmentConnecting Gas Lines from the Solenoid to the Actuator Installing the Valve Bracket Installing an Unheated Compartment Valve Valve Box for up to Six Valves Installing Valves in the Valve BoxValve Box for up to Two Valves Switching Valves Configuring ValvesGas Sampling Valves Mechanical Stop Positions for Switching Valves Operating Manual Operation Trace GC Ultra Keypad, Showing the Valves Key Operating Valves ManuallySwitching Off Gas Sample Load Vlv defaults Adding a Gas Sampling Valve Event to the Run Table Operating Valves AutomaticallyScroll to Add Run Time Event and press Enter Adding a Gas Switching Valve Event to the Run Table Heating the Valve Oven Operating ProcedureOperating Manual Leak testing TroubleshootingSymptom Cause Remedy Valve SwitchingValve Plumbing Operating Manual Europe How To Contact UsFinland Turkey United Kingdom Africa, Asia and OceaniaPeoples Republic of China Singapore North, Central and South AmericaReader Survey Page Glossary ECD See transient NPD See surge UFM Index Index Valve Oven and the Trace GC Ultra