Magikitch'n pmn operation manual MKG Series GAS Griddle

Page 7

MKG SERIES GAS GRIDDLE

1.5.3. For Use on Optional Equipment Stand:

ATTENTION

Rear mounting brackets should be installed

to the Equipment Stand prior to placing griddle on the stand.

CAUTION

Only two of the four supplied casters are equipped with a locking feature. Install the griddle so that the two locking casters are at the front of the unit. The casters should be LOCKED before the unit is placed into operation.

(See pictures this page). To mount the griddle to the stand, locate joining kit supplied with stand. The joining kit should include (2) rear mounting brackets, and (4) 1/2" mounting bolts. To mount the griddle to the equipment perform the following steps:

INSTALLATION & OPERATION

NOTICE

The larger units have 6 threaded receiving holes, but require only the four 1/2" bolts on each corner to mount the griddle.

Step 1- Remove (4) existing 1/4-20 nuts and bolts from the rear corners of the equipment stand.

Step 2- Align the 2 bolt holes on the rear corners of the stand with the 2 bolt holes on the rear mounting brackets. Orient the brackets as shown in the pictures on this page. Step 3- Install the provided rear mounting brackets (2) to the rear corners by using the existing 1/4-20 hardware that were removed in step 1, tighten securely.

Step 4- Carefully place the griddle on the equipment stand.

Step 5- Once the griddle is on the stand position the griddle on the stand so that the front edge of the base is flush with the front of the equipment stand. If the griddle is the only appliance to be mounted on the stand, then both sides of the griddle should be flush with the sides of the equipment stand.

Step 6- When positioned properly, the threaded receiving holes in the griddle base should be aligned with mating clearance holes at the front of the equipment stand, and with the clearance holes in the rear mounting brackets. Install the provided 1/2" bolts and tighten securely.

NOTICE

This appliance may only be installed with casters provided by

the manufacturer. When installed with casters, a gas connection complying with ANSI Z21.69/CGA-6.16 and a quick disconnect device complying with ANSI Z21.41/CAN 1-

6.9.It must also be installed with a restraining device to guard against putting any strain on the gas connections when

the unit is moved.

4

Image 7
Contents GAS Griddle Installation & Operation Manual To the Purchaser For Your SafetyTable of Contents GAS Connection Checking Your NEW GriddleVentilation and Fire Safety Systems Fuel Supply Line and Leak Pressure TestingFor Counter Use Without Legs INSTALLATION, SET UPMKG Series GAS Griddle Final GAS Connection Regulator AssemblySnap Action Thermostat Appliances Gas SettingsGas Type BTU/hrkW Manifold Per Burner Lighting InstructionsGriddle Surface Seasoning Surface Temperature CheckShutdown Procedure Initial StartupSnap Action and Electric Thermostats Calibration ProceduresSolid State Thermostat Operational Helpful Hints Suggested Cooking Times & TemperaturesPlain Steel Cooking Surface Daily CleaningGriddle Surface CLEANING, END of Shift Monthly MaintenancePossible Cause Troubleshooting ChartProblem AccessoriesOptional Accessories by Model