4.The MaxiMixer has also been supplied to you with a complete scale system. Read and understand the scale manual and familiarize yourself with its different functions. The scale indicator needs to be connected to a power source. Connect the scale indicators power cord directly to the solenoid operated hydraulic valve (if so equipped) or to the battery either on the mixer or the tractor. The leads are supplied with 1 white wire and 1 black wire. The white wire is to be connected to the positive and the black is to be connected to the ground. By having the scale connected to a constant power source, it will save warm up time between feedings. It is recommended to run the scale wires separately from other power lines to keep electrical interference to a minimum. A 10 amp inline fuse also protects the scale indicator.
IMPORTANT! ALWAYS DISCONNECT SCALE LEADS BEFORE PERFORMING ANY SERVICE WORK SUCH AS WELDING!
DANGER! TO PREVENT SERIOUS INJURY OR DEATH, TURN
OFF PTO, TURN OFF ENGINE AND PULL THE KEY, SET
PARKING BRAKE, AND WAIT FOR ALL MOTION TO STOP BEFORE ADJUSTING PTO LENGTH AND WORKING ON THE
DRAWBAR.