PSB Speakers G5C 0250, G5C 0018 warranty General

Page 2

PSB INDUSTRIES INC. General Air Division 1202 West 12th Street, Erie, PA. 16501

G5C Dryers

Phone : 814-45—3651 Fax : 814-454-3492 www.PSBINDUSTRIES.com psb@genair.net

 

1.0GENERAL

1.1How to use this manual

All features of this machine, including information on safety, installation, operation, and maintenance are described in this manual. This manual is an integral part of the machine and must be read and understood by any person involved with its operation or maintenance. In the event of re-sale of this unit, this manual should be forwarded to the new owner. Replacement manuals may be obtained from your authorized dealer.

1.2 Symbols

The symbols below are used throughout this manual, and on the unit itself, to indicate specific unit components or potential safety hazards that will be encountered during machine operation and maintenance.

Air inlet

Condensate drain outlet

Air outlet

Direction of rotation of fan motor

Electric shock danger!

 

1.3 Warranty

This product has been factory tested before shipment. It is guaranteed to be free from defects in material and/or workmanship for a period of 12 months from the date of shipment. This warranty applies provided the machine has been installed and used in accordance with the instructions detailed in this manual. The manufacturer agrees, at its discretion, to repair or replace all defective parts free of charge. Further, the manufacturer agrees to cover charges associated with field labor required to make authorized warranty repairs, provided the PSB-General Air warranty policy is followed and an S.I.R. authorization is issued by PSB-General Air. Labor coverage shall be limited to maximum rates as published in the latest price list. Field repairs may only be performed by a factory authorized service technician. This warranty is limited to defects associated with operation and manufacture only. All parts subject to wear due to their normal operation are not covered by this warranty. All transportation costs associated with factory repair of equipment are the sole responsibility of the owner.

1.4Standard Equipment

Refrigerated air drying circuit with economizing heat exchanger & condensate separator.

Automatic condensate drain system.

Microprocessor-based control panel with LED display and pushbutton user interface.

Instruction and maintenance manual with wiring diagram.

1.5Description Of Operation

These dryers have been specially designed to provide dry compressed air, while consuming electrical power in direct proportion to the actual load, thereby saving energy. The dryers utilize mechanical refrigeration, in conjunction with thermal storage, to condense moisture by lowering the compressed air temperature to about 37°F. The dryer “stores” its refrigeration ability during periods of low load by making ice. This allows simple and efficient “on/off” control of the refrigerant compressor to be used for capacity control. An air-to-air economizer is employed to minimize the size of the refrigeration plant and to save electrical energy. Condensed moisture is accumulated in the built-in moisture separator and is discharged through the zero air-loss drain. When the dryer is started it is automatically in the direct expansion mode and cools the compressed air by direct heat exchange with refrigerant. When the sensor temperature drops below setpoint (indicating that the dryer capacity is in excess of the load), the refrigerant solenoid valve is closed, forcing refrigerant through the ice-making circuit only. The dryer continues to run, making ice, for a predetermined time interval after which the refrigerant compressor is switched off. At this time, the LED displays the code “ICE” indicating that the dryer is cooling the compressed air by melting the ice-mass. When the sensor temperature rises sufficiently, indicating that the ice-mass has been depleted, the refrigeration system is re-started and the control cycle is repeated.

ATTENTION: although this dryer is equipped with an on/off switch & internal individual component protection, complete unit

over-current & short circuit protection MUST be provided by the installer, in the user’s power supply, before the dryer.

2/16

Cod. 710.062.01.00 – Rev.08 – 02.05.02

Image 2
Contents Glacier General Always Machine Unpacking and HandlingFilling The Thermal Mass Reservoir InstallationSET-UP Positioning Start-UpMaintenance Equipment DataG5C Dryers Button Functions Control Panel OperationStatus LEDs Set Point ModificationTroubleshooting Digital DisplayPhone ZERO-LOSS Drain Trap Maintenance10/16 OperationDimensional Data 11/1612/16 Refrigeration Circuit DiagramsElectrical Wiring Diagrams G5C 18 Thru 75 115/1/60 Cod13/16 G5C 115/1/60 Cod14/16 15/16 Cod .003.02.00 Rev G5C 250 460/3/60 Power Wiring DiagramG5C 250 460/3/60 Control Wiring Diagram 17/16 18/16 G5C 250 460/3/60 Parts List Cod .003.02.00 RevSystem Installation & Layout Diagram

G5C 0018, G5C 0250 specifications

The PSB Speakers G5C 0250 and G5C 0018 are designed to elevate your audio experience, combining innovative technologies with high-quality craftsmanship. These speakers embody the brand's commitment to delivering rich, detailed sound that brings music, movies, and games to life.

The G5C 0250 features a proprietary driver configuration that ensures a wide soundstage and exceptional clarity. It is equipped with a 5.25-inch polypropylene woofer and a 1-inch titanium dome tweeter, offering balanced playback across a broad frequency range. This speaker excels in delivering deep bass and crisp highs, making it ideal for both music enthusiasts and home theater setups. The compact design allows it to fit seamlessly into any room without sacrificing sound quality, making it a versatile option for various listening environments.

On the other hand, the G5C 0018 is a powerful option for those seeking an immersive audio experience. It boasts a dual 6.5-inch woofer system combined with a 1-inch aluminum dome tweeter. This combination permits it to produce rich bass and detailed treble, ensuring that every note of your favorite tracks is reproduced accurately. The G5C 0018 also features PSB's unique Bass Reflex design, which enhances bass performance while minimizing distortion, creating a more enjoyable listening experience.

Both models incorporate advanced technologies such as computer-optimized crossover networks that ensure smooth frequency transitions between drivers. This results in a coherent sound signature that is both natural and engaging, regardless of the genre being played. Additionally, the cabinets are constructed from high-quality MDF, reducing unwanted vibrations and resonances for clearer sound reproduction.

In terms of aesthetics, the G5C 0250 and G5C 0018 sport elegant finishes that allow them to blend seamlessly into any decor. They are available in multiple color options, providing flexibility for different interior styles.

Overall, the PSB Speakers G5C 0250 and G5C 0018 stand out as exceptional choices for anyone looking to enhance their audio experience. With their combination of advanced technologies, premium build quality, and beautiful design, these speakers deliver a performance that is sure to satisfy even the most discerning audiophiles.