Keating Of Chicago 24763 manual Thermostat Calibration 2000 Model

Page 12

every calibration. Position near primary thermostat (center) bulb is recommended.

4.Pre-2000 model: If calibration of thermostat is found to be less than 15°F(9.44°C) off, simply loosen three dial plate retaining screws, rotate dial plate to match thermometer reading and tighten screws.

2000-model: If calibration is found to be less than 15°F (9.44°C) off, remove thermostat knob. Loosen four screws in thermostat dial plate. Replace knob. Reset dial plate to match thermometer reading. Remove knob to tighten screws on dial plate and replace knob.

If the thermostat is more than 15°F(9.44°C) off then a qualified service company must be contacted to have the Pasta System properly calibrated.

Figure 4-2

Thermostat calibration (pre-2000 model shown)

Thermostat Calibration 2000 Model

(Thermostat knob removed to reveal calibration screws.)

B.The Water Auto-Fill and Low Water Safety Shut- Off Systems

The water supply connection, located at the bottom rear of the Pasta System and marked water, is a standard 3/8” female pipe connection. The water pressure should be between 20-60 psi. If the pressure exceeds 60 psi, a pressure regulator must be used. The water temperature must not exceed 150°F(65.6°C). Hot or warm water is not needed due to the instant recovery of the Pasta System.

Connections suitable for hot water must be used. All connections must be tested for leaks before using the Pasta System.

￿NOTE: For Pasta Systems with casters, flexible hose must be used to avoid leaking when the Pasta System is moved for cleaning.

Control of the water level is fully automatic with the auto-fill system. The water level is controlled by two circuit boards and two sensors. The sensors are located in the tube on the right side of the overflow deck. The upper sensor controls the water level and the lower sensor controls the low water safety shut-off system. Once the water On/Off switch is turned on, the blue light will come on and start to fill until the water level reaches the upper sensor. The burners will not come on until the water level reaches the lower sensor, preventing the Pasta System from being damaged if there is little or no water in it. Both sensors must be cleaned with the sensor brush (like the one provided) on an hourly basis or whenever starch foams up to maintain the proper water level. Sensors must be cleaned more often in areas with hard water, in installations with softened water (due to the salt in the water) or when oil or salt is placed in the water for cooking.

The brush must be checked on a regular basis and replaced whenever it starts to wear.

Do not store the sensor brush in the sensor tube as it could contact the sensors, which could allow the water level to drop below the heat tubes and damage the Pasta System.

Using a worn brush could damage the sensors.

￿NOTE: Water level problems caused by the sensors not being cleaned adequately will not be covered under warranty.

WHEN THE WATER LEVEL FALLS BELOW THE LOWER SENSOR THE BURNERS WILL SHUT OFF. IF THEY STAY ON, TURN THE MAIN POWER ON/OFF SWITCH TO THE “OFF” POSITION AND CLEAN THE SENSORS THOROUGHLY. IF THE PROBLEM STILL OCCURS, HAVE THE WATER AUTO-FILL SYSTEM CHECKED BY A QUALIFIED SERVICE TECHNICIAN.

Figure 4-3 Sensor Tube Location

10

Image 12
Contents Custom Pasta System Electric Service Manual Post this Label in a Prominent Location on Your Unit Table of Contents Introduction Safety Precautions II Installation If Equipment Arrives DamagedConcealed Loss or Damage Visible Loss or DamagePositioning Restraining DevicesLeveling Electrical ConnectionIII Operation Cleaning DrainingHOW to Program the Keating Electronic Timer Timer Operating Instructions Digital TimersFor ALL Models Except 14 BASKET-LIFT ProgrammingIV Maintenance Warranty RepairsPreventive Maintenance Limited CalibrationThermostat Calibration 2000 Model Service Diagnosis Cooker Heating SectionTroubleshooting Chart Problem Probable Cause Solution VI Parts List Custom Pasta System Electric Control Panel AssemblyOrdering Parts Item # Description QTYParts List for Custom Pasta System Description ModelsVII Wiring Diagrams Electric Pasta 2-THERMOSTAT Wiring Diagram Without TimersElectric Pasta with Digital Timers Wiring Diagram Page Page Page Electric Pasta 2-THERMOSTAT Wiring Diagram Without Timers Electric Pasta with Digital Timers Wiring Diagram Warranty Serving Those Who Serve The Very Best