Siemens SG020 owner manual Roof C1 CPL

Page 47

1

0F7003 (XX)

1

ROOF C1 CPL

2

0F7004 (XX)

1

CORNER POST LH SIDE C1 CPL

3

0F7008 (XX)

1

DOOR REAR C1 CPL

4

0F7005 (XX)

1

CORNER POST RH SIDE C1 CPL

5

0F7007 (XX)

2

DOOR LH & RH SIDE C1 CPL

6

0F7006 (XX)

1

DUCT FRONT DISCHARGE C1 CPL

7

0F4487A

1

ASSEMBLY, COVER ACCESS

8

0912970091

1

ASSY WIRE 14AWG 13.8" GRN/YEL

9

0912970090

2

ASSY WIRE 14AWG 33.5" GRN/YEL

10

0E5968

1

GASKET EXTRUDED TRIM (356” LG)

11

0E3257

6

SCREW HWHTF M6-1.0 X 16

12 **

077992

18

NUT HEX LOCK M6-1.0 SS NY INS

13

0F5049

3

TAB PULL

14

0F5048D

3

VISE-ACTION LATCH, SLOTTED CIR

15

022473

1

WASHER FLAT 1/4-M6 ZINC

16

022097

1

WASHER LOCK M6-1/4

17

022127

1

NUT HEX 1/4-20 STEEL

18

0C2454

24

SCREW THF M6-1 X 16 N WA Z/JS

19

078115

20

WASHER SELF LOCKING DOME

20

0F3890B

2

RETAINER INSULATION (820)

21

0F3890

4

RETAINER INSULATION (450)

22

0F7365

2

INSULATION SIDE DOOR C1

23

0F7365B

1

INSULATION REAR DOOR C1 CPL

24

0F7365A

1

INSULATION ROOF C1 CPL

25

0F8869D

1

KEY VISE-ACTION LATCH SLOT CIR

OPTIONAL COMPARTMENT MATERIALS:

ALL P/N’S WITH AN (XX) SUFFIX INDICATE A MULTIPLE MATERIAL AND COLOR OPTION.

USE THE FOLLOWING LEGEND TO IDENTIFY THE CORRECT PART NUMBER:

PART NO.

MATERIAL

COLOR

0XXXXXSN

STEEL

TAN

0XXXXXAN

ALUMINUM

TAN

0XXXXXSG

STEEL

GRAY

0XXXXXAG

ALUMINUM

GRAY

**ALUMINUM ENCLOSURE NOTE: ALL ENCLOSURE PANELS THAT FASTEN TO THE BASE FRAME MUST BE SECURED USING ITEM 18 & 11 THREAD FORMING FASTENER AND ITEM 12 LOCK NUT. LOCK NUT IS TO BE INSTALLED AFTER THREAD FORMING FASTENER HAS PENETRATED THROUGH EXTRUSIONS IN ENCLOSURE PANELS. ALL ROOF PANELS ARE TO BE SECURED IN THE SAME MANNER.

Image 47
Contents SG020 Series 1.6L 20kW Standby Generator Sets Table of Contents  Warning   Electrical Hazards  Introduction ‹ Operation and Maintenance‹ HOW to Obtain Service Authorized Service Dealer Location‹ Data Label Identification RecordCoolant Recommendations Equipment DescriptionEngine OIL Recommendations Engine Protective Devices ‹ Natural GAS Fuel System Fuel System‹ Fuel Requirements Specifications ‹ Cold Weather KIT ‹ Reconfiguring the Fuel SystemGenerator AC Lead Connections Alternator Power Winding Connections‹ FOUR-LEAD, SINGLE-PHASE Stator ‹ 3-PHASE AlternatorsInitial Inspection for Genset Startup InstallationPreparation Before START-UP ‹ Preparation for START-UP START-UP Checklist‹ Retransfer and Shutdown Operating Unit with Manual Transfer SwitchGenerator Control Operation ‹ Engine START-UP and TransferChecking Fluid Levels Maintenance Performed by Service FacilitiesCooling System Maintenance Owner Operator can Perform ‹ Spark Plugs ‹ Changing the Engine AIR Cleaner ‹ Coolant Change‹ Changing Engine OIL Miscellaneous Maintenance Service Maintenance Interval Information Service ScheduleLevel Maintenance Level Problem Cause Correction Troubleshooting GuideStandby Generator Sets Standby Generator Sets Standby Generator Sets Standby Generator Sets Page Breaker Tray BACK/BOTTOM Page Assy RTR 20KW 2PH Page Components Included in 0G1291E Page Support Radiator LH Side Page Battery Tray C1 CPL Page Mounting Base 1.6L Page Engine Generac 1.6L NG Page ASM Motor Stepper Page Elbow 90D 3/4 NPT Page Roof C1 CPL Page Muffler C1 Page Page Page Page Page Page Page Page Page Page Page Page Page Page Standby Generator Sets Warranty

SG020 specifications

Siemens SG020 is a cutting-edge turbine designed for a variety of energy applications, particularly in the field of renewable energy generation and industrial processes. As one of the latest innovations from Siemens, this turbine is engineered for efficiency, reliability, and environmental sustainability.

One of the main features of the SG020 is its advanced aerodynamic design. This turbine is built with large rotor blades that optimize wind capture, allowing it to function effectively even in low-wind conditions. The blades are also constructed from lightweight composite materials, enhancing both performance and durability. This design maximizes energy output while minimizing wear and tear, thereby extending the operational lifespan of the turbine.

Incorporated within the Siemens SG020 is an intelligent control system that utilizes state-of-the-art sensors and software algorithms. This technology continuously monitors wind conditions and turbine performance, automatically adjusting the blade pitch and rotor speed to optimize energy production. The smart grid capabilities of the turbine allow it to integrate seamlessly with existing energy systems, making it a flexible solution for various applications, from powering remote communities to integrating with larger industrial facilities.

Another key characteristic of the SG020 is its commitment to sustainability. The turbine is designed to operate with minimal environmental impact, producing clean energy while reducing carbon emissions. Siemens has implemented eco-friendly manufacturing processes and materials in the production of the turbine, underlining the company’s dedication to environmentally responsible energy solutions.

Maintenance of the SG020 is also streamlined through innovative technology. Predictive maintenance features leverage data analytics to anticipate potential issues before they arise, allowing for timely interventions that further reduce downtime and maintenance costs. This enhances the overall reliability of the turbine, making it a dependable choice for energy generation.

The SG020 stands out as a flexible and efficient solution for delivering renewable energy. With its advanced technologies, robust design, and commitment to sustainability, it represents Siemens’ ongoing pursuit of innovation in the energy sector, paving the way for a more sustainable future in power generation.