McCulloch REX 450 Extension Cable and Plug Wiring UK only, Plug Replacement, Female Connector

Page 8

g

RELECTRICAL SAFETY

1)Current The trimmer is suitable for AC supply only.

2)Voltage Ensure the rating marked on your machine is correct for your supply.

3)Plugs We recommend the use of PVC or rubber covered plugs and connectors.

4)Power Point

The machine must be connected to a power point and not a light socket.

5) Residual Current Circuit Breaker (RCB)

For increased safety, we strongly recommend that the electrical power to the machine be supplied through a high sensitivity RCB. RCB’s are designed to give additional personal protection against harmful electric shock should a fault occur. RCB devices to fit into household sockets can be obtained from good electrical stores.

6) Extension Cables (for models without wired-in cable)

The electrical supply on your machine is fitted with a “male” connector to facilitate the use of an extension cable system. Ensure you use an extension cable fitted with the appropriate splashproof “female” connector and intended for outdoor usage. If in any doubt contact your dealer.

This machine is double insulated and therefore needs only a 2-core cable. You can fit up to 40 metres of 1.0 mm2 (2-core) circular cables without affecting product performance.

The “male” connector already attached to the supply cable inside your machine is designed to be non-rewirable. Please return to your dealer if any maintenance is needed to this.

EXTENSION CABLE AND PLUG WIRING (UK ONLY)

We strongly recommend the use of a splashproof extension cable intended for outdoor use fitted with both a moulded plug and moulded connector.

If an appliance or extension cord is fitted with a non-rewirable plug which does not fit standard socket outlets in the home, it should be cut off and an appropriate three pin plug fitted in accordance with the instructions below.

WARNING: Never wire an extension cable with anything other than the correct female connector and a 13A BS1363A approved plug with a 13 amp fuse. Never wire a ‘male’ connector to your extension cable and never wire an extension cable with a plug of any kind at both ends of the cable. This is very dangerous and results in the pins being live which may cause a fatal electric shock.

PLUG REPLACEMENT

If you are competent to do this, proceed as follows. If in doubt, contact a qualified electrician. Cut off the plug and dispose of it safely.

A plug with bared wires is Fit a BS or ASTA approved plug

Earth E

 

 

 

extremely hazardous, potentially lethal, if

Fit a

 

engaged in a live socket outlet.

Connect blue

 

recommended fuse.

 

Extension cables contain two

to N/Neutral

Connect

 

wires which are coloured for easy recognition

 

Brown

 

and these colours or a letter will be marked at

 

to L/Live

230 Volts only

the connection points of most good quality plugs.

 

 

Never use a

Attach the Brown wire (Live) to the connection in

Make sure that the outer

light socket

the plug marked ‘L/Live’. Attach the Blue wire

sheath protrudes through

 

(Neutral) to the connection in the plug marked

the clamp and is held firmly

 

 

 

‘N/Neutral’.

WARNING: Do not make any connection to the earth terminal of the plug marked ‘E’ or #. If the cable or plug is damaged you must unplug from the mains before checking.

If a fuse cover is required, ensure it is fitted.

FEMALE CONNECTOR

Each of the two wires leading into the female connector should be connected to either side of the terminal block. It does not matter which way round they are positioned. Before refitting the top cover of the mains plug, or outer casing of the female connector, make sure that the cable clamp is holding the outer sheath of the cable firmly.

Wiring an extension cable directly into the machine should only be carried out by an Authorised Service Dealer. Should the cable on your machine become damaged or need replacing, please return your machine to your dealer.

2

Image 8
Contents REX 450 REX 500 REX Page 96dBA Page Page GB Specifications FR Caracteristiques TechniquesDE Technische Daten IT Dati TecniciUsage Power Supply CableClothing Female Connector Extension Cable and Plug Wiring UK onlyPlug Replacement Debris Shield Installation REX Disposable Cutting Head Installation and RemovalFault Finding UsagePage Electrolux Group. The world’s No.1 choice