Operation (continued)
LED Function with Switch in "CHARGE ONLY" Position
Approximate Charge Rate Indication
Resetting Your Inverter/Charger to Restore AC Power
|
| LEDs |
|
|
|
|
| Illuminated | Charge Rate | ||
1 |
| All three lights on | Overcharge | ||
|
|
| error* |
| |
|
| Red | 75% | - | 100% |
2 |
| ||||
|
| Red & Yellow | 50% | - | 75% |
3 |
| ||||
|
| Yellow | 25% | - | 50% |
4 |
| ||||
|
| Green | 0% - 25% | ||
5 |
|
|
|
| Your Inverter/Charger may cease supplying AC power or DC charg- |
|
|
| ing power in order to protect itself from overload or to protect your |
|
|
| electrical system. To restore normal functioning: |
1 | 2 | 3 | Overload Reset: Switch operating mode switch to “OFF” and |
|
|
| |
|
|
| remove some of the connected electrical load (ie: turn off some of |
|
|
| the AC devices drawing power which may have caused the overload |
|
|
| of the unit). Wait one minute, then switch operating mode switch |
4 | 5 | 6 | back to either “AUTO/REMOTE” or “CHARGE ONLY.” |
6 All three lights off | 0% |
*If all three lights remain on, an internal fault may exist. Turn off and disconnect the unit. Then, call Tripp Lite at (773)
Output Circuit Breaker Reset: Alternatively, check output circuit breaker(s) on the unit's front panel. If tripped, remove some of the elec- trical load, then wait one minute to allow components to cool before resetting the circuit breaker. See Troubleshooting for other possible reasons AC output may be absent.
Configuration
Set Configuration DIP Switches
Using a small tool, set the Configuration DIP Switches (located on the front panel, see diagram) to optimize Inverter/Charger operation depending on your application. RV612UL and RV612ULH models include one set of four DIP Switches. All other models include an additional set of four DIP switches to configure additional operational functions. Refer to the appropriate section to review the instructions for your spe- cific model.
B4 | B3 | B2 | B1 | A4 | A3 | A2 | A1 |
|
|
| C/B |
| OUTPUT C/B 12A |
|
Group B Dip Switches (Not on 612 Models) | Group A Dip Switches (All Models) |
|
Group A DIP Switches (All Models)
Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on the front panel of your unit; see diagram) as follows:
A1 Select Battery
(All models)
CAUTION: The Battery Type DIP Switch setting must match the type of batteries you connect, or your batteries may be degraded or damaged over an extended period of time. See “Battery Selection,” p. 10 for more information.
A4 A3 A2 A1
A2 Select High AC Input Voltage Point
for Switching to
(All Models)
A4 A3 A2 A1
Battery Type | Switch Position |
Gel Cell (Sealed) Battery | Up |
Wet Cell (Vented) Battery | Down (factory setting) |
Voltage | Switch Position |
145V | Up |
135V | Down (factory setting) |
*Most of your connected appliances and equipment will perform adequately when your Inverter/Charger’s High AC Input Voltage Point (DIP Switch #2 of Group A) is set to 135V and its Low AC Voltage Input Point (DIP Switches #3 and #4 of Group A or DIP Switch #3 for 612 models) are set to 95V. However, if the unit frequently switches to battery power due to momentary high/low line voltage swings that would have little effect on equipment operation, you may wish to adjust these settings. By increasing the High AC Voltage Point and/or decreasing the Low AC Voltage Point, you will reduce the number of times your unit switches to battery due to voltage swings.