cleared. In addition to the minimum reading, the unit displays the date and time of its occurrence. The date and time display must not be on hold in order to display both date and time.

Maximum

The maximum key functions the same as the minimum key, but with maximum readings.

Scale

The scale key changes the displays from reading in English values to those of Metric values. The inch light near the rain display is on when the instrument is in English mode. The English to Metric equivalents are miles per hour or Knots to Kilometers per hour, Fahrenheit to Celsius, Inches of Mercury to Millibars, Inches of rain to Centimeters of rain. Pressing the select and scale key at the same time puts the unit into calibration mode. If the unit is in protect mode, this function is disabled.

Report

Pressing the report key sends current data to the serial port. The report key, when depressed at the same time as the select key, puts the unit into its time setting function. Pressing the report key while in logging mode will send all data in memory from the currently displayed record forward to the RS-232 port.

Hold

The hold key when depressed (toggled on) stops the cycling between two different parameters on the same display.

Windchill

The Windchill key, when depressed, calculates and displays, using wind speed and temperature, a factor that represents how cold the temperature and wind feel to bare flesh. Pressing the windchill and the comfort key at the same time will display the dew point.

Comfort

The comfort key, when depressed, calculates and displays, using humidity and temperature, a factor which represents how warm the temperature feels.

Last

The last key, when depressed, displays the time and date of the last rainfall and its rainfall rate. When depressed at the same time as the clear key, the instrument clears the term rainfall register. When last is pressed at the same time as select, the unit enters into rainfall history mode.

Average

When toggled on, the dot below the Av light (near the wind speed display), indicates that the unit is in wind averaging mode. When in wind averaging mode, the instrument displays the previous minute's average wind direction and speed. When depressing the average key and the select key at the same time, the unit enters into the printer set mode.

Texas Weather Instruments, Inc.

5

WRL Instruction Manual

Image 5
Contents WRL InstallationTexas Weather Instruments, Inc Texas Weather Instruments, Inc Minimum SelectClear Scale MaximumReport HoldHold ¸Time Setting Mode42 PM Calibration Method 51 PMHold - 3 Rainfall 29 .9Humidity Sensor Calibration 1023 29 .9 2 2.3 SETTINGMIN/MAX Form Feed Rain Rate Operation via RS-232 Command CharactersTexas Weather Instruments, Inc Option Value Control OptionsRS-232 Interface DE 9 Plug HeaderComputer Interface Modem InstallationTypical Output Barometric Pressure TemperatureHumidity Sensor Calibration RainfallClearing the Memories Report FlagLunar Tide Cycle Rainfall history mode LED FCC Radio Frequency Interference Statement Operation