Westinghouse UL-ES-VectorElite-WH09 Check main and branch circuit fuses or circuit breakers

Page 20

Troubleshooting guide

TROUBLE

SUGGESTED REMEDY

UL-ES-VectorElite-WH09

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.

1. If fan does not start:

1. Check main and branch circuit fuses or circuit breakers.

 

2.

Check wire connections as performed in step #17 or #18 of installation.

 

 

CAUTION: Make sure main power is turned off.

 

3. Make sure forward/reverse switch is firmly in up or down position.

 

 

Fan will not operate when switch is in the middle.

 

4.

If the fan still will not start, contact a qualified electrician.

 

 

Do not attempt to troubleshoot internal electrical connections yourself.

2. If fan sounds noisy:

1. Check to make sure all screws in motor housing are snug (not over tightened).

 

2. Check to make sure the screws which attach the fan blade holder to the motor are tight.

 

3.

Some fan motors are sensitive to signals from Solid State variable speed controls.

 

 

DO NOT USE a Solid State variable speed control.

 

4.

Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear

 

 

after this period.

3. If fan wobbles:

All blades are weighed and grouped by weight. Natural woods vary in density which could cause

 

the fan to wobble even though all blades are weight-matched. The following procedures should

 

eliminate most of the wobble. Check for wobble after each step.

 

1.

Check that all blades are screwed firmly into blade holders.

 

2.

Check that all blade holders are tightened securely to motor.

 

3.

Make sure that canopy and mounting bracket are tightened securely to ceiling joist.

 

4.

If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute

 

the weight and possibly result in smoother operation.

4. If light does not work:

1. Check for faulty light bulbs.

 

2.

If light kit will still not operate, contact a qualified electrician for assistance.

NOTICE

This ‘Energy Policy Act 2005’ compliant fan includes a device that limits the total wattage of its light fixture to 190 watts.

By installing a combination of light bulbs that exceeds 190 watts or if an electrical surge causes the wattage to exceed 190 watts, the light fixture will either dim the lights to 190 watts or will automatically turn off.

To restore the light levels, make sure the total wattage of the light bulbs does not exceed 190 watts and follow the applicable directions below:

For fans with Pull Chains:

Pull the light fixture’s pull chain two times to reset the light fixture. If the power to your fan is controlled by a toggle wall switch, it may be necessary to turn the power off and back on at the wall switch.

For fans with Wall Controls:

Press the light button on the wall control “off” and “on”

once to reset the light fixture.

For fans with Remote Controls:

If you verify the wattage and the lights do not turn on, press the light button on the remote control twice to reset the light fixture.

NOTE: If the procedures above do not reset the lights,

turn off the main power source, located at the breaker panel or box,

and then turn it on again.

20

Image 20
Contents Manual del usuario Safety tips Consejos de seguridad May require a longer downrod Sold separately Features CaracterísticasInstalación con PREPARING for installation Antes de la instalación UL-ES-VectorElite-WH09 Blade Installation Instalación de las paletas MOUNTING OPTIONS Opciones DE Montaje Choose a MOUNTING OPTION Elija una Opción DE MontajeProceed Directly to PAGE 14 FOR WIRING OPTIONS FLUSH MOUNT Option Opción DE Instalación AL RASNORMAL DOWNROD OPTION Para Cielorraso NormalOpción CON Varilla Vertical MÁS Larga Loosen downrod ball 1 from downrod 2 by removing set screwSlide downrod ball 1 off of downrod and remove pin UL-ES-VectorElite-WH09 Mounting Montaje Wiring Options Opción DE CableadoAsegure el ventilador al cielorraso Install light bulbs Instale las bombillas de luz UL-ES-VectorElite-WH09 OPERATION AND MAINTENANCE OperationOperación y mantenimiento OperaciónFan will not operate when switch is in the middle Weight and possibly result in smoother operationCheck for faulty light bulbs Check main and branch circuit fuses or circuit breakersReparar conexiones eléctricas internas No los apriete demasiadoAl motor estén apretados No USE un control de velocidad variable de estado sólidoUL-ES-VectorElite-WH09 PARTS LIST Lista DE Repuestos Interruptor de control de luzUL-ES-VectorElite-WH09