Xantrex Technology Link 1000 manual Record of System Settings

Page 69

Record of System Settings

Record of System Settings

 

 

 

Your

 

 

 

Setting or

 

Setting

 

Recorded

 

Default

Data

 

 

 

 

 

 

Battery Volts (charged)

13.2

 

 

 

 

 

 

 

 

Battery Amps (charged)

2%

 

 

 

 

 

 

 

 

Battery Capacity

200Ah

 

 

 

 

 

 

 

 

Power Share

Model dependent

 

 

 

 

 

 

 

 

Idle Mode

4W

 

 

 

 

 

 

 

 

CEF

 

 

 

 

 

 

 

 

 

Number of CEF

 

 

 

 

Recalculations

 

 

 

 

 

 

 

 

 

Average depth of discharge

 

 

 

 

 

 

 

 

 

Deepest depth of discharge

 

 

 

 

 

 

 

 

 

Functions

 

 

 

 

 

 

 

 

 

Auto Display Scanning (F01)

Off

 

 

 

 

 

 

 

 

Display Sleep (F02)

On

 

 

 

 

 

 

 

 

Ambient Battery

70° F (21.11° C)

 

 

 

Temperature (F03)

 

 

 

 

Note: F03 depends on F16.

 

 

 

 

 

 

 

 

 

Ah / kilowatt hours (F04)

Ah

 

 

 

 

 

 

 

 

Alternate Energy Mode (F05)

Off

 

 

 

 

 

 

 

 

Manually set CEF (F06)

95%. This value

 

 

 

 

should only be set

 

 

 

 

if you don’t want

 

 

 

 

the Link 1000 to

 

 

 

 

calculate CEF

 

 

 

 

automatically.

 

 

 

 

 

 

 

 

 

 

 

 

61

Image 69
Contents Link Date and Revision Contents Setting up the Link Using the Link Product and System Information SpecificationsFigures Viii Describes Introducing LinkIntroducing the Link Inverter/Charger Control FunctionsMonitoring Functions Introducing the Link Link 1000 Control Panel Reading the Link 1000 Control PanelRESET, DATA, LOCK, Func LEDs Indicates that AC power is present Where to go From HereGives Installing the LinkRefer to on Planning the InstallationInstallation Considerations Color-Coded Wiring Overview of Installation Steps Installing the LinkSystem Overview Wiring To mount the control panel Mounting the Link 1000 Control PanelTo mount and cable the shunt Mounting and Cabling the ShuntTo wire the terminal block Wiring the Terminal BlockTo connect the terminal block wires Connecting Terminal Block Wires to Shunt and BatteryConnecting the Phone Cable Installing FusesTesting the Installation To install fusesDisconnecting the Inverter/Charger MaintenanceExplains Setting up the LinkTo enter Setup mode and change a value About Link 1000 SettingsResetting Values Locking Your Setup ValuesTo lock the setup To reset valuesBattery Size Battery CapacityTo change the Battery Type setting To change the Battery Capacity settingTo change the Ambient Temperature setting Charged Parameters To change the Charged Voltage settingTo change the Charged Current Percentage To change the Time Remaining settingTo change Power Share values To change the Idle mode setting Advanced Function Values F03 Set or Display Ambient Battery Temperatures Default Off = Auto recalculation of CEF F08 Set Peukert’s Exponent F10 Select Battery Type F14 Test Control Panel Display Default Off Using Link Monitoring Functions Choosing a Display Unit Volts, Amps, Ah, or TimeTo change the display unit Reading the Battery State-of-Charge Battery StatusInverter Functions Changing the Idle Mode SettingTurning on the Invert Function To turn on the invert functionSummary of Charger Status LEDs Charging FunctionsCharging the Batteries Equalizing the BatteriesTo start a charge cycle To end an equalization cycle manually To start an equalization cycleActivating Power Share Battery Capacity TestingTo change the Power Share setting To test battery capacity To synchronize the Link 1000 to the battery Synchronizing the Link 1000 to the BatteryOver-charge Ah Accumulation of Positive Ah To access battery history Battery HistoryBattery History Error Code Meaning Reading Error CodesE09 E013 Appendix a lists SpecificationsControl Panel Physical Specifications Control Panel Electrical SpecificationsInverter/Charger Controls Default SettingsPage Appendix B contains Product System InformationWarranty Warranty Disclaimer ProductExclusions Return Material Procedure Return Material Authorization PolicyProduct Information Setting Record of System SettingsSetting Numerics IndexIndex Lock LED Index

Link 1000 specifications

Xantrex Technology's Link 1000 is a sophisticated monitoring and control system designed primarily for the mobile power and renewable energy sectors. Capable of being integrated into various systems, from RVs to marine applications, the Link 1000 empowers users with the ability to efficiently manage their power resources.

One of the defining features of the Link 1000 is its comprehensive display panel, which offers users real-time data on their battery status, including voltage, current, and state of charge. This information is essential for maintaining optimal battery health and ensuring that users have a clear understanding of their power usage at any given moment. The LCD screen is user-friendly, providing clear visual indications of power levels and alarms in a straightforward manner.

The Link 1000 incorporates advanced technologies to enhance usability and performance. Its built-in intelligence allows for automatic recognition of various battery types, including AGM, gel, and flooded lead-acid batteries. This feature ensures that the charging strategy is optimized based on the specific needs of the battery, prolonging its life and improving overall efficiency.

Additionally, the Link 1000 includes programmable features that allow users to set customized charging profiles and thresholds. Users can specify parameters such as voltage cutoffs and charging current limits, making it easier to tailor the system to their unique power requirements. This level of customization is particularly beneficial for users who operate in diverse environments or have specific energy consumption patterns.

Another impressive characteristic of the Link 1000 is its remote monitoring capability. Users can connect to the system via Bluetooth or other communication means, enabling them to access vital power data from a distance. This is especially advantageous for those using the device in hard-to-reach areas, such as in remote camping sites or aboard boats.

In terms of installation, the Link 1000 is designed for flexibility; it can be mounted either vertically or horizontally, allowing it to fit seamlessly into various locations. The compact design ensures that it does not take up excessive space, which is a notable advantage in confined environments.

In summary, the Xantrex Technology Link 1000 stands out for its intuitive interface, advanced battery management capabilities, remote monitoring options, and customizable settings. These features make it an essential tool for anyone looking to optimize their energy consumption and manage their power systems effectively, whether on land or at sea.