Xantrex Technology Link 1000 manual Index

Page 72

Index

battery temperature sensor, effect on settings 20

battery type setting 23, 33

C

cable clamp 9 CCC 36

CEF recalculation 46 CHARGE button LED 5

charged current percentage setting 25 charged parameters 25 CHARGER STATUS LEDs, described

39

Charging Efficiency Factor (CEF) 31, 46

CHG LED 6, 39 control panel

electrical specifications 52 illustrated 4

mounting 13

physical specifications 52 testing 34

D

DATA LED 5 deepest discharge 47 default settings 53 display panel, testing 34 display units

changing 36 described 5

displaying Ah 36 Amps 36

Time remaining 36 Volts 36

E

E99 46

electrical specifications, control panel 52

equalize charge 40 gel cell batteries 42 starting 41 stopping manually 41

Error Codes 0L 50

E01 48

E010 49

E012 50

E014 50

E015 50

E02 48

E03 48

E04 48

E05 49

E06 49

E07 49

E08 49

error codes, displayed 36, 48

F

F01 Auto Display Scanning 29

F02 Display Sleep 29

F03 Ambient Battery Temperature

Setting 30

F04 Ah / kWhr Display 30

F05 Alternative Energy Mode 31

F06 Manually Set CEF 31

F07 Temperature Coefficient 31

F08 Peukert’s Exponent 32

F09 Low Battery Discharge Floor 32

F10 Battery Type 33

F11 Second Battery Voltage Sense 33

64

Image 72
Contents Link Date and Revision Contents Setting up the Link Using the Link Specifications Product and System InformationFigures Viii Introducing Link DescribesIntroducing the Link Inverter/Charger Control FunctionsMonitoring Functions Introducing the Link Reading the Link 1000 Control Panel Link 1000 Control PanelRESET, DATA, LOCK, Func LEDs Where to go From Here Indicates that AC power is presentInstalling the Link GivesPlanning the Installation Refer to onInstallation Considerations Color-Coded Wiring Installing the Link Overview of Installation StepsSystem Overview Wiring Mounting the Link 1000 Control Panel To mount the control panelMounting and Cabling the Shunt To mount and cable the shuntWiring the Terminal Block To wire the terminal blockConnecting Terminal Block Wires to Shunt and Battery To connect the terminal block wiresInstalling Fuses Connecting the Phone CableTesting the Installation To install fusesMaintenance Disconnecting the Inverter/ChargerSetting up the Link ExplainsAbout Link 1000 Settings To enter Setup mode and change a valueLocking Your Setup Values Resetting ValuesTo lock the setup To reset valuesBattery Capacity Battery SizeTo change the Battery Capacity setting To change the Battery Type settingTo change the Ambient Temperature setting To change the Charged Voltage setting Charged ParametersTo change the Time Remaining setting To change the Charged Current PercentageTo change Power Share values To change the Idle mode setting Advanced Function Values F03 Set or Display Ambient Battery Temperatures Default Off = Auto recalculation of CEF F08 Set Peukert’s Exponent F10 Select Battery Type F14 Test Control Panel Display Default Off Using Link Monitoring Functions Choosing a Display Unit Volts, Amps, Ah, or TimeTo change the display unit Battery Status Reading the Battery State-of-ChargeChanging the Idle Mode Setting Inverter FunctionsTurning on the Invert Function To turn on the invert functionCharging Functions Summary of Charger Status LEDsCharging the Batteries Equalizing the BatteriesTo start a charge cycle To start an equalization cycle To end an equalization cycle manuallyActivating Power Share Battery Capacity TestingTo change the Power Share setting To test battery capacity Synchronizing the Link 1000 to the Battery To synchronize the Link 1000 to the batteryOver-charge Ah Accumulation of Positive Ah Battery History To access battery historyBattery History Reading Error Codes Error Code MeaningE09 E013 Specifications Appendix a listsControl Panel Electrical Specifications Control Panel Physical SpecificationsDefault Settings Inverter/Charger ControlsPage Product System Information Appendix B containsWarranty Warranty Disclaimer ProductExclusions Return Material Authorization Policy Return Material ProcedureProduct Information Record of System Settings SettingSetting Index NumericsIndex Lock LED Index

Link 1000 specifications

Xantrex Technology's Link 1000 is a sophisticated monitoring and control system designed primarily for the mobile power and renewable energy sectors. Capable of being integrated into various systems, from RVs to marine applications, the Link 1000 empowers users with the ability to efficiently manage their power resources.

One of the defining features of the Link 1000 is its comprehensive display panel, which offers users real-time data on their battery status, including voltage, current, and state of charge. This information is essential for maintaining optimal battery health and ensuring that users have a clear understanding of their power usage at any given moment. The LCD screen is user-friendly, providing clear visual indications of power levels and alarms in a straightforward manner.

The Link 1000 incorporates advanced technologies to enhance usability and performance. Its built-in intelligence allows for automatic recognition of various battery types, including AGM, gel, and flooded lead-acid batteries. This feature ensures that the charging strategy is optimized based on the specific needs of the battery, prolonging its life and improving overall efficiency.

Additionally, the Link 1000 includes programmable features that allow users to set customized charging profiles and thresholds. Users can specify parameters such as voltage cutoffs and charging current limits, making it easier to tailor the system to their unique power requirements. This level of customization is particularly beneficial for users who operate in diverse environments or have specific energy consumption patterns.

Another impressive characteristic of the Link 1000 is its remote monitoring capability. Users can connect to the system via Bluetooth or other communication means, enabling them to access vital power data from a distance. This is especially advantageous for those using the device in hard-to-reach areas, such as in remote camping sites or aboard boats.

In terms of installation, the Link 1000 is designed for flexibility; it can be mounted either vertically or horizontally, allowing it to fit seamlessly into various locations. The compact design ensures that it does not take up excessive space, which is a notable advantage in confined environments.

In summary, the Xantrex Technology Link 1000 stands out for its intuitive interface, advanced battery management capabilities, remote monitoring options, and customizable settings. These features make it an essential tool for anyone looking to optimize their energy consumption and manage their power systems effectively, whether on land or at sea.