York P2DHX16F12001, P3DHX12F08001 Table A-4 Direct Drive Blower Characteristics, Model FLA, Tip

Page 13

TABLE A-4: DIRECT DRIVE BLOWER CHARACTERISTICS

FURNACE

 

MOTOR

MOTOR

TEMP.

 

 

 

CFM

 

 

BLOWER

RISE

SPEED

 

External Static Pressure – inches w.c.

 

MODEL

HP

FLA

 

 

 

(T)

 

 

 

 

 

 

 

 

0.20

0.30

0.40

0.50

0.60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1469

1386

1308

1213

1123

 

 

 

 

 

 

 

 

 

 

 

P3DHX12F08001

GT10

½

7.7

70° - 90°F

Med-High

1377

1308

1224

1143

1063

 

 

 

 

 

 

Med-Low

1088

1075

1038

985

916

 

 

 

 

 

 

 

 

 

 

Low

721

721

712

688

649

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1752

1691

1659

1593

1525

P2DHX16F12001

G12-10

1/2

7.7

70° - 90°F

Med-High

1454

1454

1417

1379

1300

 

 

 

 

 

 

Med-Low

975

944

912

879

844

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

631

593

552

515

486

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1810

1740

1675

1585

1510

 

 

 

 

 

 

 

 

 

 

 

P2LBX16F14501

G10

1/2

7.7

70° - 90°F

Med-High

1570

1540

1495

1445

1375

Med-Low

1090

1080

1070

1065

1050

 

 

 

 

 

 

 

 

 

 

Low

710

700

690

665

650

 

 

 

 

 

 

 

 

 

 

 

TABLE A-5: BELT DRIVE BLOWER CHARACTERISTICS

 

 

Motor

 

 

Blower

Motor

 

 

 

CFM

 

 

 

Furnace Model

Motor HP

 

Blower

Pulley

 

 

 

 

 

 

 

T

 

External Static Pressure – Inches water column

 

FLA

Pulley

Turns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Out

0.20

 

0.30

0.40

0.50

 

0.60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

2274

 

2080

1847

1532

 

1099

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4LBX20F19001

3/4 HP

13.0

85°F

G12

7 x ¾

2

2107

 

1927

1712

1420

 

1019

 

 

 

 

 

 

 

 

4

1939

 

1775

1576

1308

 

939

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

1772

 

1622

1441

1196

 

859

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIP:

These formulae will assist with the design of the ductwork and the determination of airflow delivery:

CFM =

Bonnet Output

SystemTemperature Rise=

Bonnet Output

(1085.x SystemTemperature Rise)

(1085. x CFM)

13

Image 13
Contents Contents Installation ManualHeat Loss IntroductionLocation of Unit NON-SUSPENDED Installation DOWN-FLOW Installation Horizontal InstallationAIR Conditioning Suspended InstallationCombustion AIR Chimney VentingDraft Regulator Control Common Chimney ProblemsMinimum Chimney Base Temperatures F Piping InstallationOIL Tank Electrical ConnectionsCirculating AIR Blower Neutral Wire normally the white wire is Never Moved to ADJust the Blower Speed OIL Burner ProcedureBurner Electrodes OIL Burner SET-UPStack Temperature Furnace Installation SET-UPSmoke Test Note Operating Instructions Maintenance and ServiceBTU/Hr Table A-1 Beckett OIL Burner SET-UPDelavan Pressure Rate PlateTable A-3 Belt Drive Blower SET-UP Table A-2 Direct Drive Blower SET-UPOutput Motor Blower SET-UP Cooling Capacity Furnace Table A-5 Belt Drive Blower Characteristics Table A-4 Direct Drive Blower CharacteristicsFurnace Motor Temp CFM Blower Rise Speed Model FLAGeneral Dimensions P2LBX16F14501 General Dimensions P4LBX20F19001 General Dimensions P3DHX12F08001 General Dimensions P2DHX16F12001 Page Page Thermostat calls for heat R7184 Detailed Sequence of OperationOperation R8184N Notes R7184 LED Diagnostic LightPreliminary Steps Table C-2 R7184 Troubleshooting But Control locks out and starts Before Oil Problem Possible Cause Remedy Table C-3 System and General TroubleshootingLow oil pump pressure Check stack temperature. Stack temperatures will normally P3DHX Series Downflow Configuration Notes P4LBX20F19001 Assembly NotesP3DHX12F08001 Vestibule KIT Repair Part List P3DHX12F08001A Repair Part List P2DHX16F12001A Repair Part List P2LBX16F14501A Repair Part List P4LB Series Replacement Part Contact Information Page Unitary 5005 Norman Products York Group Drive 73069

P4LBX20F19001, P2DHX16F12001, P3DHX12F08001, P2LBX16F14501 specifications

The York P2LBX16F14501, P3DHX12F08001, P2DHX16F12001, and P4LBX20F19001 are high-performance HVAC units designed to meet diverse heating and cooling needs in both residential and commercial environments. These models are notable for their energy efficiency, advanced technologies, and user-friendly features.

The York P2LBX16F14501 is particularly known for its advanced inverter-driven scroll compressors that offer precise temperature control, enhanced efficiency, and significant noise reduction. This model is equipped with a multi-speed blower that helps maintain consistent airflow while ensuring optimum comfort levels. Its compact design allows for flexible installation options, making it suitable for various applications.

In contrast, the York P3DHX12F08001 focuses on delivering robust heating solutions, incorporating a variable-speed fan motor designed for improved energy savings and optimal performance. This unit excels in environments with fluctuating temperature demands, providing reliable heating without sacrificing energy efficiency. With built-in diagnostics, maintenance becomes more manageable, allowing for timely interventions to prevent excessive downtime.

The York P2DHX16F12001 stands out with its dual-fuel capability, allowing users to seamlessly switch between gas and electric sources depending on the prevailing energy costs. This versatility not only ensures year-round comfort but also offers substantial savings on energy bills. The model's high SEER (Seasonal Energy Efficiency Ratio) rating is indicative of its capability to deliver cooling efficiently during peak summer months.

Lastly, the York P4LBX20F19001 is designed for larger spaces, featuring a higher capacity that makes it ideal for commercial applications. This unit leverages advanced refrigerant technologies, enabling it to operate effectively across a wider range of temperatures. Its intelligent control systems can be integrated with building management systems, providing real-time monitoring and remote access to ensure peak operational efficiency.

All four models share a commitment to sustainable design and longevity, integrating modern materials that enhance durability and reduce the environmental footprint. Each unit is engineered with user comfort and energy efficiency in mind, representing York's dedication to innovation and quality in the HVAC industry.