York P3DHX12F08001, P2DHX16F12001, P4LBX20F19001 installation manual Repair Part List P2LBX16F14501A

Page 32

REPAIR PART LIST – P2LBX16F14501A

ITEM

DESCRIPTION

1

Panel, Side (Left)

2

Panel, Side (Right)

3

Panel, Rear (Upper)

4

Panel, Blower Division

5

Panel Assembly, Base

6

Panel, Inner Front

6A

Bezel, Logo

6B

Label, Logo

7

Door, Blower Access

7A

Handle, Door

8

Panel, Front Door

9

Panel, Top Front

10

Heat Exchanger Assembly

11

Flue Pipe Assembly

12

Retaining Bracket, Firepot

13

Chamber, Replacement Combustion

14

Baffle, Top Front

15

Baffle, Inner Front

16

Baffle, Right Side Panel

17

Mounting Plate Assy., Oil Burner

17A

Gasket, Inspection Door

18

Gasket, Pouch

19

Gasket, Flue Pipe (2 Req’d)

20

Cover Assembly, Radiator Cleanout (2Req’d)

20A

Gasket, Clean Out Cover (2 Req’d)

21

Clean-out Cover, Casing (2 req’d)

22

Filter, Air (20”x 20”x1”, Permanent)

23

Box, Junction

24

Wire Harness, Blower Direct Drive

25

Wire Harness, Fan and LImit

ITEM

DESCRIPTION

26

Centre, Fan

26A

Relay, Replacement (Centre Fan)

27

Control, Fan and LImit (5”, 200 Deg.)

27A

Fuse ABC 15 Amp Slow Blow

27B

Fuse Holder

28

Regulator, Draft (6”)

29

Support, Fan & LImit/Insulation Retainer

30

Insulation Retainer, Side Panel (2 Req’d)

31

Burner, Oil

31A

Motor, Burner

31B

Pump, Oil

31C

Ignitor, Solid State

31D

Combustion Control, Primary

31E

Tube Combination, Air

31F

Retention Head, Flame

31G

Nozzle, (1.00/80 Deg.A)

Nozzle, (1.20/60 Deg.A)

 

32

Blower Assembly, Complete

32A

Housing, Blower and Wheel

32B

Wheel, Blower

32C

Motor, Blower

32D

Mount Band, Motor

32E

Mount Arms, Motor (3 Req’d)

32F

Run Capacitor, Motor (10MFD/370VAC)

32G

Strap, Capacitor

32H

Insulator, Capacitor

32I

Blower Feet, Blower (LH)

32J

Blower Feet, Blower (RH)

32

Image 32
Contents Installation Manual ContentsLocation of Unit IntroductionHeat Loss DOWN-FLOW Installation Horizontal Installation NON-SUSPENDED InstallationSuspended Installation AIR ConditioningCombustion AIR Chimney VentingCommon Chimney Problems Draft Regulator ControlPiping Installation Minimum Chimney Base Temperatures FOIL Tank Electrical ConnectionsJust the Blower Speed Neutral Wire normally the white wire is Never Moved to ADCirculating AIR Blower Procedure OIL BurnerBurner Electrodes OIL Burner SET-UPSmoke Test Note Furnace Installation SET-UPStack Temperature Maintenance and Service Operating InstructionsTable A-1 Beckett OIL Burner SET-UP BTU/HrDelavan Pressure Rate PlateOutput Motor Blower SET-UP Cooling Capacity Furnace Table A-2 Direct Drive Blower SET-UPTable A-3 Belt Drive Blower SET-UP Table A-4 Direct Drive Blower Characteristics Table A-5 Belt Drive Blower CharacteristicsFurnace Motor Temp CFM Blower Rise Speed Model FLAGeneral Dimensions P2LBX16F14501 General Dimensions P4LBX20F19001 General Dimensions P3DHX12F08001 General Dimensions P2DHX16F12001 Page Page R7184 Detailed Sequence of Operation Thermostat calls for heatOperation Preliminary Steps R7184 LED Diagnostic LightR8184N Notes Table C-2 R7184 Troubleshooting But Control locks out and starts Before Oil Table C-3 System and General Troubleshooting Problem Possible Cause RemedyLow oil pump pressure Check stack temperature. Stack temperatures will normally P4LBX20F19001 Assembly Notes P3DHX Series Downflow Configuration NotesP3DHX12F08001 Vestibule KIT Repair Part List P3DHX12F08001A Repair Part List P2DHX16F12001A Repair Part List P2LBX16F14501A Repair Part List P4LB Series Replacement Part Contact Information Page Unitary 5005 Norman Products York Group Drive 73069

P4LBX20F19001, P2DHX16F12001, P3DHX12F08001, P2LBX16F14501 specifications

The York P2LBX16F14501, P3DHX12F08001, P2DHX16F12001, and P4LBX20F19001 are high-performance HVAC units designed to meet diverse heating and cooling needs in both residential and commercial environments. These models are notable for their energy efficiency, advanced technologies, and user-friendly features.

The York P2LBX16F14501 is particularly known for its advanced inverter-driven scroll compressors that offer precise temperature control, enhanced efficiency, and significant noise reduction. This model is equipped with a multi-speed blower that helps maintain consistent airflow while ensuring optimum comfort levels. Its compact design allows for flexible installation options, making it suitable for various applications.

In contrast, the York P3DHX12F08001 focuses on delivering robust heating solutions, incorporating a variable-speed fan motor designed for improved energy savings and optimal performance. This unit excels in environments with fluctuating temperature demands, providing reliable heating without sacrificing energy efficiency. With built-in diagnostics, maintenance becomes more manageable, allowing for timely interventions to prevent excessive downtime.

The York P2DHX16F12001 stands out with its dual-fuel capability, allowing users to seamlessly switch between gas and electric sources depending on the prevailing energy costs. This versatility not only ensures year-round comfort but also offers substantial savings on energy bills. The model's high SEER (Seasonal Energy Efficiency Ratio) rating is indicative of its capability to deliver cooling efficiently during peak summer months.

Lastly, the York P4LBX20F19001 is designed for larger spaces, featuring a higher capacity that makes it ideal for commercial applications. This unit leverages advanced refrigerant technologies, enabling it to operate effectively across a wider range of temperatures. Its intelligent control systems can be integrated with building management systems, providing real-time monitoring and remote access to ensure peak operational efficiency.

All four models share a commitment to sustainable design and longevity, integrating modern materials that enhance durability and reduce the environmental footprint. Each unit is engineered with user comfort and energy efficiency in mind, representing York's dedication to innovation and quality in the HVAC industry.