Shindaiwa EB344EF13, X7501930200 manual Maintenance Intervals, Maintenance Procedure Notes

Page 13

Maintenance Intervals

 

MAINTENANCE

DAILY OR

EVERY

3 MONTHS

YEARLY

COMPONENT / SYSTEM

OR 135

PROCEDURE

BEFORE USE

REFUEL

600 HOURS

 

HOURS

 

 

 

 

 

 

 

 

 

 

 

Air Filter

Inspect/Clean

I / C *

 

R *

 

 

 

 

 

 

 

Choke Shutter

Inspect/Clean

I / C

 

 

 

 

 

 

 

 

 

Fuel Filter

Inspect/Replace

 

 

I *

I / R *

 

 

 

 

 

 

Fuel Cap Gasket

Inspect/Replace

 

 

I *

R *

 

 

 

 

 

 

Fuel System

Inspect/Replace

I (1) *

I (1) *

 

 

 

 

 

 

 

 

Spark Plug

Inspect/Clean/Replace

 

 

I / C / R *

 

 

 

 

 

 

 

Cooling System

Inspect/Clean

I / C

 

 

 

 

 

 

 

 

 

Valve Adjustment

Inspect/Adjust

 

 

(2)

 

 

 

 

 

 

 

Muffler Spark Arrestor

Inspect/Clean/Replace

 

 

I / C / R *

 

 

 

 

 

 

 

Recoil Starter Rope

Inspect/Clean

I / C *

 

 

 

 

 

 

 

 

 

Screws/Nuts/Bolts

Inspect/Tighten/Replace

I *

 

 

 

 

 

 

 

 

 

MAINTENANCE PROCEDURE LETTER CODES: I = INSPECT, R = REPLACE, C = CLEAN

IMPORTANT NOTE - Time intervals shown are maximum. Actual use and your experience will determine the frequency of required maintenance.

MAINTENANCE PROCEDURE NOTES:

(1) Low evaporative fuel tanks DO NOT require regular maintenance to maintain emission integrity.

(2) Adjust every 135 hours.

* All recommendations to replace are based on the finding of damage or wear during inspection.

13

Image 13
Contents X7501930200 07/10 EB344 BlowerIntroduction Table of ContentsWork Safely General Safety InstructionsStay Alert Use Good JudgmentBe Aware of the Working Environment Properly Equipped OperatorUnit Description ContentsEmission Control Exhaust & Evaporative SpecificationsAssembling the Blower Handling Fuel Mixing FuelFilling the Fuel Tank Starting ProcedureStarting the Engine After useStarting a Flooded Engine When The Engine StartsStopping The Engine Throttle Control Operating BlowerTwo-hand Operation MaintenanceMaintenance Procedure Notes Maintenance IntervalsAir Filter Fuel FilterCooling System Spark PlugBy a Shindaiwa-trained service technician Valve AdjustmentExhaust System Carburetor AdjustmentLong Term Storage Idle AdjustmentWhat To Check Troubleshooting GuidePossible Cause RemedyEngine is knocking Symptom Possible Cause Remedy Exceptions Purchased Repair Parts and Accessories 01/2010 Page Page Page Parts/Serial Number Servicing Information