| Installation | ||
Installation |
|
|
|
|
|
|
|
|
|
The MA6900 can be placed upright on a table or shelf, | (2.54cm) on each side of the amplifier, so that airflow is | ||||||||
standing on its four feet. It also can be custom installed in a | not obstructed. Allow 20 inches (50.8cm) depth behind the | ||||||||
piece of furniture or cabinet of your choice. The four feet | front panel. Allow 1 inch (2.54cm) in front of the mounting | ||||||||
may be removed from the bottom of the MA6900 when it | panel for knob clearance. Be sure to cut out a ventilation | ||||||||
is custom installed as outlined below. The four feet to- | hole in the mounting shelf according to the dimensions in | ||||||||
gether with the mounting screws should be retained for | the drawing. |
|
|
|
|
|
| ||
possible future use if the MA6900 is removed from the |
|
|
|
|
| ||||
custom installation and used free standing. The required |
|
|
|
|
| ||||
panel cutout, ventilation cutout and unit dimensions are |
|
|
|
|
| ||||
shown. |
|
|
|
|
|
|
| ||
Always provide |
|
|
|
|
|
|
| ||
adequate ventilation |
|
|
|
|
|
|
| ||
for your MA6900. | MA6900FrontPanel |
| 43.34cm |
|
|
| |||
Cool operation en- |
|
|
|
|
|
| |||
sures the longest |
|
|
|
|
|
| |||
possible operating |
|
|
|
|
|
| |||
life for any elec- |
|
|
|
|
|
| |||
tronic instrument. Do | CustomCabinetCutout | 15.24cm6" | CutoutOpeningforCustomMounting | ||||||
not install the |
| Cbinet |
|
| |||||
MA6900 directly |
|
|
| ||||||
above a heat generat- |
|
|
| ||||||
ing component such |
|
|
| ||||||
as a high powered |
|
|
| ||||||
amplifier. If all the |
|
|
| ||||||
components are in- |
|
|
|
|
|
|
|
| |
stalled in a single |
|
|
|
|
|
|
|
| |
| Front |
|
|
|
|
|
|
| |
cabinet, a quiet run- |
| Panel |
|
|
|
|
|
|
|
| Openig |
|
|
|
|
|
|
| |
ning ventilation fan |
|
|
|
|
|
|
|
| |
can be a definite as- | MA6900SideView | forVetilationn |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
set in maintaining all |
|
|
|
|
|
|
|
| |
the system compo- |
|
|
|
|
|
|
|
| |
nents at the coolest |
|
|
|
|
|
|
|
| |
possible operating |
|
|
|
|
|
|
|
| |
temperature. | inCustomCabinet | upport | CutoutOpeningforVentilation | Chssis |
| ||||
A custom cabinet |
|
| |||||||
installation should |
|
| |||||||
provide the follow- |
|
| |||||||
| Shelf | 2.54cm1" |
|
|
| Spacers |
| ||
ing minimum spac- |
|
|
|
|
| ||||
ing dimensions for | MA6900BottomView | 5.028"cm |
|
| 13" |
| |||
cool operation. Al- |
| ||||||||
low at least 6 inches |
| ||||||||
(15.24cm) above the |
| ||||||||
36.83cm |
| ||||||||
top, 2 inches | Cutout |
|
| ||||||
(3.81cm) below the | inCustomCabinet |
|
|
| 33.02cm | 26.35cm | 35.88cm | ||
|
| Opening |
|
|
|
|
|
| |
bottom and 1 inch |
|
| for |
| 13" |
|
|
|
|
|
|
| Ventilation |
|
|
|
|
| |
|
|
|
| 33.02cm |
|
|
| ||
6 |
|
|
|
|
|
|
|
|
|