DANGER

“DANGER” indicates a possibility of death or serious injury if instructions

 

 

are not followed.

 

 

 

 

 

WARNING

“WARNING” indicates a strong possibility of severe personal injury or loss of

 

 

life if instructions are not followed.

 

 

 

 

 

CAUTION

“CAUTION” indicates a possibility of personal injury or equipment damage

 

 

if instructions are not followed.

 

 

 

 

WARNING

Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire.

Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use open flame near the fuel tank. Be careful not to spill fuel during refueling.

If fuel is spilt, wipe it off and let dry before starting the engine.

WARNING

Do not place in flammables near the generator.

Be careful not to place fuel, matches, gunpowder, oily cloths, straw, trash, or any other in flammables near the generator.

ESPAÑOL

WARNING

Do not operate the generator inside a room, cave, tunnel, or other insufficiently ventilated area.

Always operate it in a well-ventilated area, otherwise the engine may become overheated, and the poisonous carbon monoxide gas, an odorless, colorless, poison gas, contained in the exhaust gas will endanger human lives.

Operate generator only outdoors and far from open windows, doors, ventilation intakes and other openings.

Keep the generator at least 1 meter (3 feet) away , including overhead, from any structure or building use.

WARNING

1m

1m

Do not enclose the generator nor cover it with a box. The generator has a built-in forced air cooling system, and may become overheated if it is enclosed.

If generator has been covered to protect it from the weather during non use, be sure to remove it and keep it well away from the area during generator use.

WARNING

Operate the generator on a level surface.

It is not necessary to prepare a special foundation for the generator.

However, the generator will vibrate on an irregular surface, so choose a level place without surface irregularities. If the generator is tilted or moved during operation, fuel may spill and / or the generator may tip over, causing a hazardous situation.

Proper lubrication cannot be expected if the generator is operated on a steep incline or slope. In such a case, piston seizure may occur even if the oil is above the upper level.

WARNING

Pay attention to the wiring or extension cords from the generator to the connected device.

If the wire is under the generator or in contact with a vibrating part, it may break and possibly cause a fire, generator burnout, or electric shock hazard.

Replace damaged or worn cords immediately.

WARNING

Do not operate in rain, in wet or damp conditions, or with wet hands.

The operator may suffer severe electric shock if the generator is wet due to rain or snow.

- 1 -

Image 6
Contents Subaru Generator AIR Index Cpsc 16 CFR PartContents ForewordEspañol Française English RGX2900, RGX3600, RGX4800 RGX6500, RGX7500 Safety Precautions English FrançaiseAvertissement Specifications ModelComponents RGX2900, RGX3600, RGX4800RGX6500, RGX7500 Control Panel RGX6500, 7500 w/Starter motor PRE-OPERATION Checks Check Engine OILRecommended engine oil Check Engine Fuel Fuel AmountChecking Component Parts Check Generator SurroundingsGrounding Generator Operating Procedures Starting the GeneratorWarm up the engine without a load for a few minutes Using Electric Power AC ApplicationTo take power out from the Twist Gfci Receptacle Full Power Switch Except RGX2900 Idle Control Switch Except RGX2900 HOW to USE Idle Control SwitchDC Application Stopping the Generator OIL SensorWattage Information Voltage Drop in Electric Extension Cords Spark Arrester Maintenance Schedule Periodic MaintenanceDaily Inspection Periodic Maintenance Schedule table HOW-TO Maintenance Servicing the AIR CleanerEngine OIL Change Cleaning and Adjusting Spark Plug Cleaning Fuel StrainerHigh Altitude Engine Operation Checking Carbon Brush RGX6500 Preparation for Storage Troubleshooting When Engine Fails to StartWiring Diagram RGX2900 60Hz-120VRGX3600 60Hz-120/240V RGX4800 60Hz-120/240V RGX4800w / Starter motor 60Hz-120/240VRGX6500,7500 60Hz-120/240V EngineRGX6500,7500 w / Starter motor 60Hz-120/240V GeneratorPage Issue EMD-GU7220

RGX2900, RGX4800 RGX6500, RGX3600, RGX7500 specifications

The Subaru RGX series is a collection of high-performance generators designed to meet a variety of power demands. This line-up includes models such as the RGX7500, RGX3600, RGX4800, RGX6500, and RGX2900, each offering distinct features tailored to different user needs.

Starting with the RGX7500, this model is one of the most robust in the series. It boasts a powerful 7,500-watt surge capacity, making it ideal for heavy-duty applications, including construction sites and large-scale outdoor events. Its Subaru EX-series engine is both efficient and reliable, offering excellent fuel economy and long run times. The RGX7500 also includes a durable steel frame and large fuel tank, contributing to its ruggedness and suitability for demanding jobs.

Next, the RGX3600 is known for its versatility and compact design. With a surge capacity of 3,600 watts, it is perfect for home backup during power outages or light commercial use. This generator features Subaru’s advanced inverter technology, which ensures clean, stable power suitable for sensitive electronics. The RGX3600 is lightweight and easy to transport, making it a popular choice among weekend warriors and campers.

The RGX4800 strikes a balance between performance and portability, offering 4,800 watts of surge capacity. Users appreciate its dual fuel capability, allowing it to run on either gasoline or propane, providing flexibility in fuel options. The model is equipped with a user-friendly control panel, making it easy to operate even for those unfamiliar with generators.

On the larger end of the spectrum, the RGX6500 delivers a robust 6,500-watt surge capacity, combining power and efficiency. Its advanced cooling system ensures longevity during extended use, while its heavy-duty features make it ideal for job sites or as a backup power source for homes. The RGX6500 is also equipped with electric start capability, simplifying the starting process, especially during emergencies.

Lastly, the RGX2900 is aimed at users who need a reliable and compact solution for smaller power needs. With a 2,900-watt surge capacity, it is perfect for recreational activities, such as camping or tailgating events. This model’s lightweight design, along with its efficient fuel consumption, makes it a go-to option for on-the-go users.

In summary, the Subaru RGX series provides a range of generators that cater to diverse power needs, ensuring reliability, efficiency, and user-friendly operation across all models. Whether for heavy-duty applications or light recreational use, there’s a suitable option within this versatile lineup.