| Troubleshooting Guide | ||
|
|
|
| |
| Pressure Washer Will Not Run - No Power | |||
| Causes |
|
| Solutions |
| Machine not plugged in |
|
| Plug machine in |
| GFCI tripped |
|
| Make sure machine is dry. Press RESET on the GFCI |
| Machine turned OFF |
|
| Turn Pump switch ON |
| Line circuit breaker tripped |
|
| Check for tripped circuit breaker in building |
|
|
| ||
|
| Circuit Breaker Trips During Operation | ||
| Causes |
|
| Solutions |
| Voltage too low |
|
| Check the voltage |
| Circuit Breaker Overloaded |
|
| Make sure to use NEMA specified receptacle. Make sure there is no other |
|
|
|
| equipment using the same circuit. - see Specifications |
| Pressure set too high |
|
| Check/adjust pressure setting on unloader. |
|
| |||
| Pressure Washer Runs But No Pressure | |||
| Causes |
|
| Solutions |
| Partially clogged or damaged nozzle |
|
| Clean or replace nozzle |
| Low water flow |
|
| Make sure the water supply is more than 4 gpm |
|
| |||
| Pressure Washer Surges Or Cycles While In Bypass | |||
| Causes |
|
| Solutions |
| Leak between unloader and gun. |
|
| Check all connections between unloader and gun for leaks. Tighten loose |
|
|
|
| components and replace damaged components. |
| Gun leaking internally |
|
| Replace spray gun |
|
|
| ||
|
| Smoke From Heat Exchanger | ||
| Causes |
|
| Solutions |
| Air band not adjusted properly | due to | Adjust the air band until the burner burns cleanly. See Oil Burner under | |
| different elevation |
|
| Installation Instructions |
| Poor quality fuel |
|
| Use Kerosene for the cleanest burn |
|
|
| ||
|
| Water Not Heating Sufficiently | ||
| Causes |
|
| Solutions |
| Scale |
|
| See Coil Descaling under Maintenance Instructions |
| Coil is full of soot |
|
| See Coil Desooting under Maintenance Instructions |
|
|
| ||
|
| Safety Relief Valve Sprays Water | ||
| Causes |
|
| Solutions |
| Unloader/Burner Control Problem |
|
| Call customer service |
|
|
| ||
|
| Poor Or No Detergent Supply | ||
| Causes |
|
| Solutions |
| Soap control knob set too low. |
|
| Adjust soap control knob |
| Inadequate detergent supply |
|
| Refill detergent container. Make sure the chemical strainer is fully |
|
|
|
| submerged |
| High pressure hose too long |
|
| Use less hose. Move machine closer to the work. |
| Chemical strainer or injector clogged |
|
| Clean the strainer and injector. Always start with a clean detergent |
|
|
|
| container. Run clean water through the injector after each use. |