V.) Getting Started

IMPORTANT: Proper initial installation of equipment will assure more satisfactory performance, longer service life, and lower maintenance cost.

IMPORTANT: The use of a back flow preventer (Part #222815 call 1-800-270-0810 to order) on the water supply hose is recommended and may be required by local code.

Make sure the pressure washer is on a level surface and in a protected area where it is not readily influenced by outside forces such as strong winds, freezing temperatures, rain, etc. Locate the pressure washer for easy access for filling fluids, adjustments, and maintenance.

It is recommended that a partition be made between the wash area and the pressure washer to prevent direct nozzle spray from coming in contact with the pressure washer. Moisture reaching the equipment will reduce the pressure washer’s service life.

Partition

V.) Venting

DANGER: Do not run machine indoors or in an enclosed area without adequate ventilation, or in areas where flammable vapors, (gasoline, solvents, etc.) may be present. Do not vent exhaust gases into a wall, a ceiling, or a concealed space.

CAUTION: All venting must be in accordance with applicable federal and state laws, and local ordinances. Consult local heating contractors.

If the pressure washer is to be used in an enclosed area, a flue must be installed to vent burner exhaust to the outside atmosphere. Be sure the flue is the same size as the burner exhaust vent on the pressure washer lid. Poor draft will cause the pressure washer to soot and not operate properly. When selecting the location for installation, beware of poorly ventilated locations or areas where exhaust fans may cause an insufficient supply of oxygen. Proper combustion can only be obtained when there is a sufficient supply of oxygen available for the amount of fuel being burned. If it is necessary to install a unit in a poorly ventilated area, outside fresh air may have to be piped to the burner and a fan installed to bring sufficient air into the unit. Locate the pressure washer in such a manner that the flue will be as straight as possible and protrude through the roof

at a proper height and location to provide adequate draft. This oil fired unit must have a draft controller installed in the flue. A draft controller will permit proper upward air flow of exhaust flue gases.

VI.) Oil Burner

Burner Air Adjustment: The oil burner is preset and performance tested at the factory (elevation 1100 feet). A one-time initial correction of the burner for your location will pay off in economy, performance, and extended service life.

Air Band

White

Arrow

Locking

Burner

Screw

 

1.) Turn the pump and heat switches on (Refer to “Operation” for details). Have someone operate the spray gun so the burner fires.

2.) Loosen the locking screw and close the air band until black smoke appears from the burner exhaust vent. Note the position of the white arrow on the air band.

3.) Slowly open the air band until white smoke just starts to appear.

4.) Turn the air band half way back to the black smoke position previously noted. Tighten the locking screw.

5.) Fine tune the burner air by loosening the shutter lock screw and turning the shutter until the exhaust is cleanest. Tighten the shutter lock screw.

Shutter

Shutter

Lock Screw

CAUTION: If white smoke appears from the burner exhaust vent during start-up or operation, discontinue use and readjust air bands.

NOTE: If a flue is installed, have a professional serviceman adjust your burner for a #1 or #2 smoke spot on the Bacharach scale.

9

Image 9
Contents Item Number 157321,322,325,326 MhotpwrTable of Contents Important Safety InstructionsExtension Cords Grounding Instructions157321 157322 157325 157326 Specifications Item NumberDescription Ref # Machine Component IdentificationUnpack Installation InstructionsDescription Qty II. Assembly InstructionsAxle Wheel RetainerIII. Pump Preparation Quantities Of FluidIV. Chemical Injector Preparation Venting Getting StartedVI. Oil Burner Air Band White Arrow Locking Burner ScrewPre-Operation Operating InstructionsII. Check Your Water Supply III. Before StartingAttach Nozzle VI. Turn the pump switch onVII. For Hot Water NozzleII. High Temperature Limit Safety ReliefFor Steam Optional To StopMaintenance Mode Maintenance InstructionsMaintenance Schedule Description 157321 157322 157325 157326Changing The Pump Oil Checking the Tire Air Pressure Cleaning The Inlet FilterBurner Fuel Filter SAE 11.0oz 0.33LCoil Desooting Coil DescalingElectrodes Long Term Storage Moving and Handling InstructionsManeuvering Your Pressure Washer Lifting Your Pressure WasherTroubleshooting Guide Hotpwr 157321,157322,157325 HOTPWR- 157321,157322,157325,157326 Description QTY Model 2SFX AR XMV35G25D-F23 AR XTV2G15EBA-F8 AR XTV3G16D-F8 Page