Multiquip gbe/gbce Balloon saFety, Generator saFety, EleCtriCal saFety, Power Cord/Cable safety

Page 8

Safety Information

Balloon saFety

Warning

To prevent serious burns, never touch or unzip the balloon envelope when the

lamp is on.

Caution

ALWAYS keep the balloon away from sharp objects and excessive amounts of heat.

NOTICE

To prevent balloon deformation, never use lighting system in strong winds.

do not place the balloon inside its protective cover until the lamp has had a suffi cient amount of time to cool down. This will prevent the balloon’s nylon cover from being burned (touching the lamp surface).

ALWAYS place the balloon inside its protective cover after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements.

Replace balloon immediately if damaged. A damaged balloon will not infl ate properly, and may become more damaged by touching the hot lamp surface.

do not use excessive force when zipping and unzipping the balloon. Be gentle with the zipper mechanism. If the zipper is broken, the balloon will become unusable.

generator saFety

If using a generator to power lighting system, refer to applicable generator manual safety information section.

eleCtriCal saFety

danger

Lighting system is equipped with a ground pin on the power plug. For your protection, ALWAYS complete the grounding path. never insert the AC power plug into a 2-prong receptacle to operate lighting system.

When applying power to the lighting system, ALWAYS connect the AC power plug to a 3-prong receptacle that is grounded. The possibility exists of electrical shock, electrocution and even death if the lighting system is not grounded.

never operate lighting system or handle any electrical equipment while standing in water, while barefoot, while hands are wet or in the rain.A dangerous electrical shock could occur, causing severe bodily harm or even death.

ALWAYS make sure the area above

the lighting system is open and clear of overhead power lines and other obstructions. Contact with overhead power lines or other obstructions could result in equipment damage, electrical shock, electrocution and even death.

power Cord/Cable safety

danger

never let power cords or cables lay in water.

never use damaged or worn cables or cords. Inspect for cuts in the insulation

never grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death.

Make sure power cables are securely connected. Incorrect connections may cause electrical shock and damage to the lighting system.

NOTICE

ALWAYS make certain that proper power or extension cord has been selected for the job. See Cable Selection Chart in this manual.

page 8 — GBC/GBCE lighting system • operation and parts manual — rev. #1 (03/25/14)

Image 8
Contents Model GBC/GBCE This Manual Must Accompany the Equipment AT ALL TimesProposition 65 warning Table of Contents GBC/GBCEChoose from three easy options SaFety symBols Safety InformationSaFety messages General saFety Lighting system saFety Lamp saFety never attempt service on a running machine  never unplug the lamp’s AC power cable during operationBalloon saFety Generator saFetyEleCtriCal saFety Power Cord/Cable safetyTransporting Safety Loading and UnloadingCart Type With Lifiting Hook Cart Type No Lifiting HookSpecifications Dimensions 40.5 02928.3 718.8 305Footcandle plot Illumination RangeGeneral information Extension Cord Gauge SelectionGbce only ComponentsExtension Pole Gbce Only Extends mast height by 40 inches Setup Fold the balloon cover into itself and zip it up. See FigureConnecting the Power Cable Operation Applying Parking BrakeReleasing Parking Brake Deploying outriggerStowing Outrigger Raising the mastApplying Power Lowering the MastShutdown Shutting down lamp onlyDisconnect the lamp connector from the AC power cable StorageRemove the lamp guard MaintenanceReplacing Lamp Zip up the top and bottom of the new balloon. See Figure Replacing BalloonUnzip the top and bottom of the balloon. See Figure Filter replacement Locking Air PlateLoose? Lamp does not lightUnplug all other appliances Wait for lamp to cool downC11 C10 C5 C8 Lamp Base Lamp base loose? Screw in securely Connector Adjust Link for front shaftSpray grease Brake Not working properly? Adjust Power cable Defective or worn cable? Replace PlugWiring diagram Black Electronic White BallastPage Explanation of Code in Remarks Column Suggested Spare Parts GBC/GBCE lIGHTING System 1 to 3 unitsGloBugTM Lighting System Nameplates and decalsA400193800 A400193400A400193700 A400193500Balloon and lamp assy 0024304008 Screw M4x8 A300167500 E0000382000025304025 Screw & Washer M4x25 A300174000 A300160601Mast assy A300169400 A300169300A300169200 A400187600Base assy A100054500 A300147201A300147301 A300056800Outrigger assy A300162202 1641001430A400175302 A400176901Terms and Conditions of Sale Parts Page HERE’S HOW to GET Help

gbe/gbce specifications

Multiquip’s GBE/GBCE series represents a fusion of innovation and reliability in the construction equipment market. These generators are specifically designed to meet the diverse needs of contractors and service providers, offering both performance and versatility in a compact package.

One of the main features of the GBE/GBCE generators is their robust construction. Designed to withstand harsh job site conditions, these units are housed in durable enclosures that provide excellent protection against environmental elements. The weather-resistant design ensures that the generators can operate efficiently in various climates, making them suitable for both indoor and outdoor applications.

Power delivery is another hallmark of the GBE/GBCE series. With a wide range of models available, these generators are capable of producing power outputs that cater to different project requirements. The GBE series focuses on efficiency and performance, while the GBCE series introduces advanced starting technology that enhances reliability, reducing the chances of downtime on critical workdays.

Equipped with advanced engine technology, these generators boast low emissions and noise levels, making them compliant with environmental regulations. The engines are designed for fuel efficiency, helping to minimize operational costs while maximizing uptime. Furthermore, the incorporation of innovative control systems allows for easy monitoring of performance metrics, providing operators with real-time information on generator status.

Safety is a prime consideration, and the GBE/GBCE series comes with numerous built-in safety features. These include automatic shutdown mechanisms that activate in the event of low oil levels or high temperatures, ensuring that the generator does not suffer damage during operation. The ergonomic design of the control panel enhances user experience, allowing for intuitive operation even for those with minimal experience in generator management.

In summary, Multiquip's GBE/GBCE generators embody features that prioritize durability, efficiency, and ease of use. The combination of advanced technology, environmental compliance, and user-friendly controls positions these generators as ideal solutions for a wide range of applications, from commercial construction projects to emergency backup power requirements. With a commitment to performance and reliability, the GBE/GBCE series continues to be a trusted choice for professionals in the field.