Multiquip GA-9.7 HZ operation manual Rules for Safe Operation, General Safety

Page 6

CAUTION:

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the GA-9.7 HZ Generator:

GENERAL SAFETY

DO NOT operate or service this equipment before reading this entire manual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

This generator is a source of potentially LETHAL high voltage. Never permit unqualified personnel-especially children to operate the generator.

Always refuel in a well-ventilated area, away from sparks and open flames.

Always use extreme caution when working with flammable liquids. When refueling, stop the engine and allow it to cool. DO NOT smoke around or near the machine. Fire or explosion could result from fuel vapors, or if fuel is spilled on a hot engine.

This generator is equipped with a ground terminal for your protection. Always complete the grounding path from the generator to an external grounding source.

NEVER operate this generator, or handle any electrical equipment while standing in water, while bare foot, while hands are wet, or in the rain. Electrical shock could occur causing severe bodily harm or even death.

Keep electrical cords in good condition. Worn, bare or frayed wiring can cause electrical shock, leading to bodily harm or even death.

This generator requires an adequate free flow of cooling air. Never operate the generator in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the generator and may cause injury to people.

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing generator.

RULES FOR SAFE OPERATION

Provide adequate ventilation when operating the generator. DO NOT operate the generator in any enclosed or narrow space. The generator's gasoline engine gives off DEADLY carbon monoxide gas.

NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

Always make sure that the generator is secure on level ground so that it cannot slide or shift around, endangering workers. Also keep the immediate area free of bystanders.

When using a concrete vibrator or a similar device that is immersed in a water based solution, make sure the device is equipped with short circuit protection.

Always use rubber boots and gloves when operating a concrete vibrator or similar device.

Use adequate size connecting cable for extension.

Maintain electrical cords in good condition and frequently replace the entire cable of the concrete vibrator with a new one.

HighTemperatures – Allow the machine and engine to cool before adding fuel or performing service and maintenance functions. Contact with hot components can cause serious burns.

Emergencies

Always know the location of the nearest fire extinguisher and first aid kit. Know the location of the nearest telephone. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

Always allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source

PAGE 6 — GA-9.7 HZ A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (03/05/01)

Image 6
Contents Multiquip Page Heres HOW to GET Help Table of Contents Earn Extra Discounts when You order by FAX Parts Ordering ProceduresGeneral Safety Rules for Safe OperationOperation and Safety Decals Specifications Effects of Altitude and HeatControl Box GA-9.7 HZ General InformationGenerator EngineGA-9.7 HZ Controls and Indicators GA-9.7 HZ Installation Ground the Tool GA-9.7 HZ PRE-SETUPGround the Generator VoltsFuel Main Circuit Breaker 2-Pole 60 Hz Idle Control SwitchGA-9.7 HZ Instrumentation Fuel GaugeSingle Phase Load Watts = Voltage x AmperageWarm up Before StartingStarting OperationCleaning the Fuel Strainer Air CleanerService Daily General InspectionGA-9.7 HZ Preparation for Long -TERM Storage Generator StorageGA-9.7 HZ -WIRING Diagram GA-9.7 HZ -TROUBLESHOOTING Engine GA-9.7 HZ -TROUBLESHOOTING Engine GA-9.7 HZ -TROUBLESHOOTING Generator GA-9.7 HZ -TROUBLESHOOTING Generator GA-9.7 HZ Explanation of Code in Remarks Column Items Found In the Items Number ColumnGA-9.7 HZ Suggested Spare Parts To 3 UnitsGA-9.7 HZ Generator Assy FAN Rotor Assy Includes Items W Field AssyRectifier SET BOLT, RotorGA-9.7 HZ Control BOX Assy Control BOX Idle Control SwitchOperation Switch Terminal PlateGA-9.7 HZ Pipe Frame Assy Battery Sheet Wire StopperThrottle Wire Battery BandGA-9.7 HZ Nameplate Assy Decal OIL Drain Decal BatteryDecal Ground Decal Fuel DrainHonda GX610K1 Engine Cylinder Head Assy GASKET, Cylinder Head GUIDE, EX. Valve OSCLIP, Valve Guide COVER, HeadHonda GX610K1 Engine Cylinder Barrel Assy Switch ASSY., OIL Level COLLAR, Filter SettingCLAMP, Wire COVER, BreatherHonda GX610K1 Engine Crankcase Cover Assy Cover ASSY., OIL Pump GASKET, Case CoverBOLT, Sealing SPRING, Relief ValveHonda GX610K1 Engine Crankshaft Assy Crankshaft Comp Honda GX610K1 Engine Piston Assy Bearing F Connecting ROD Bearing A, Connecting ROD BlueBearing E, Connecting ROD Bearing G Connecting RODHonda GX610K1 Engine Camshaft Assy PLATE, Governor Weight Holder SPRING, Weight ReturnHOLDER, Governor Weight PIN, Governor Weight HolderHonda GX610K1 Engine Recoil Starter Assy GRIP, Starter Starter ASSY., Recoil R8 BRT. RED Includes Items WHonda GX610K1 Engine FAN Cover Assy Hood FAN Cover PLATE, R. SidePLATE, L Side COVER, R. Side PlateHonda GX610K1 Engine Carburetor Assy CLIP, Breather Tube GASKET, AIR CleanerTUBE, Breather Gasket SETHonda GX610K1 Engine AIR Cleaner Assy GROMMET, AIR Cleaner Housing COMP., AIR CleanerCOVER, AIR Cleaner HOSE, AIR CleanerHonda GX610K1 Engine Muffler Assy Band Assy Muffler KITPipe COMP., EX GASKET,EX,PIPEHonda GX610K1 Engine Fuel Pump Assy Pump ASSY., Fuel GROMMET, WireCLIP, Wire Harness STAY, Fuel PumpHonda GX610K1 Engine Flywheel Assy Flywheel Comp FAN, CoolingPULLEY, Starter NUT, Flange 20MMHonda GX610K1 Engine Ignition Coil Assy Coil ASSY., L. Ignition GROMMET, Ignition WireCoil ASSY., R. Ignition Coil ASSY., Charge 12V/3AHonda GX610K1 Engine Starter Motor Assy Cover A, Magnetic Switch Motor ASSY., StarterNUT, Washer 6MM Honda GX610K1 Engine GOVERNOR/CONTROL Assy SPRING, Starter JOINT, RODSPRING, Return ROD, GovernorHonda GX610K1 Engine Labels LABEL, Caution LABEL, Specification GX610MARK, Emblem GX610 MARK, OIL Alert EHonda GX610K1 Engine -GASKET KIT GASKET, EX. PipeTerms and Conditions of Sale Parts Service Department 800/478-1244 or 310/537-3700 FAX 310

GA-9.7 HZ specifications

The Multiquip GA-9.7 HZ is a cutting-edge generator known for its reliability and versatile performance, making it ideal for both residential and commercial applications. This generator is engineered to deliver powerful and consistent electrical output, particularly when high performance is necessary. The GA-9.7 HZ stands out due to its robust design, advanced technologies, and user-friendly features, catering to the needs of professionals and DIY enthusiasts alike.

One of the main features of the GA-9.7 HZ is its reliable Honda GX series engine. This engine is designed for efficiency and durability, ensuring that the generator runs smoothly under varying loads. The Honda engine is complimented by an air-cooled, 4-stroke design, which significantly reduces fuel consumption while providing superior power output. With a maximum output of 9.7 kVA, the GA-9.7 HZ can easily handle the electrical demands of construction sites, outdoor events, and backup power for homes.

The generator is equipped with an automatic voltage regulator (AVR) that ensures stable voltage output. This technology is crucial for protecting sensitive electronic devices and machinery from voltage fluctuations, making the GA-9.7 HZ a dependable choice for powering essential equipment. Moreover, it features low oil shutdown, which automatically turns off the engine when oil levels drop too low, preventing potential engine damage and prolonging the lifespan of the generator.

In terms of usability, the GA-9.7 HZ is designed with convenience in mind. It features a user-friendly control panel with easy-to-read gauges, allowing operators to monitor runtime hours and voltage output at a glance. The generator is also equipped with multiple outlet options, including 120V and 240V receptacles, providing flexibility for various applications. Additionally, the generator's compact size and lightweight design make it portable and easy to transport, ensuring that it can be used in multiple locations with ease.

Durability is another hallmark of the GA-9.7 HZ. Its sturdy frame and high-quality components are designed to withstand challenging conditions often encountered on job sites. The weather-resistant enclosure further enhances its durability, allowing it to perform in diverse weather environments.

In summary, the Multiquip GA-9.7 HZ combines a powerful Honda engine, advanced technology such as AVR, and user-friendly features to create a robust and reliable generator. Its performance, portability, and durability make it an excellent choice for anyone in need of trusted power solutions.