Multiquip ga-9.7HE manual EleCTRiCal saFeTY, Power Cord/Cable safety, Grounding safety

Page 8

Safety Information

„NeveR use fuel as a cleaning agent.

„dO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

eleCTRiCal saFeTY

daNgeR

„Turn generator and all circuit breakers OFF before performing maintenance on the generator or making contact with output receptacles.

„NeveR insert any objects into the output receptacles during operation.

This is extremely dangerous. The possibility exists of electrical shock, electrocution or death.

„Backfeed to a utility system can cause

electrocution and/or property damage. NeveR connect the generator to a building’s electrical system without a transfer switch or other approved

device. All installations should be

performed by a licensed electrician in accordance with all applicable laws and electrical codes. Failure to do so could result in electrical shock or burn, causing serious injury or even death.

power Cord/Cable safety

daNgeR

„NeveR let power cords or cables lay in water.

„NeveR stand in water while AC power from the generator is being transferred to a load.

„NeveR use damaged or worn cables or cords when connecting equipment to generator. Inspect for cuts in the insulation.

„ NeveR grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death.

„Make sure power cables are securely connected to the generator’s output receptacles. Incorrect connections may cause electrical shock and damage to the generator.

NOTICE

„alWaYs make certain that proper power or extension cord has been selected for the job. See Cable Selection Chart in this manual.

grounding safety

daNgeR

„alWaYs make sure that electrical circuits are properly grounded to a suitable earth ground (ground rod) per the National Electrical Code (NEC) and local codes before operating generator. severe injury or death by electrocution can result from operating an ungrounded generator.

„NeveR use gas piping as an electrical ground.

BaTTeRY saFeTY (eleCTRiC sTaRT ONlY)

daNgeR

„dO NOT drop the battery. There is a possibility that the battery will explode.

„dO NOT expose the battery to open fl ames, sparks, cigarettes, etc.The battery contains combustible gases and liquids. If these

gases and liquids come into contact with a fl ame or spark, an explosion could occur.

„dO NOT charge battery if frozen. Battery can explode. When frozen, warm the battery to at least 61°F (16°C).

WaRNiNg

„ alWaYs wear safety glasses when handling the battery to avoid eye irritation. The battery contains acids that can cause

injury to the eyes and skin.

„Use well-insulated gloves when picking up the battery.

„alWaYs keep the battery charged. If the battery is not charged, combustible gas will build up.

„alWaYs recharge the battery in a well-ventilated environment to avoid the risk of a dangerous concentration of combustible gasses.

page 8 — GA9.7HE 60 hz gENERATOR• operation and parts manual — rev. #1 (04/29/10)

Image 8
Contents Model ga-9.7HE Proposition 65 warning Table of Contents GA9.7HE Portable 60 Hz GeneratorChoose from three easy options Safety Information SaFeTY messagesGeNeRal saFeTY GeNeRaTOR saFeTYENgiNe saFeTY Fuel saFeTYRestricted. If the air fl ow is Before servicing equipmentEleCTRiCal saFeTY Power Cord/Cable safetyGrounding safety BaTTeRY saFeTY eleCTRiC sTaRT ONlYTRaNspORTiNg saFeTY ENviRONmeNTal saFeTYSpecifications gENERATOR Specifications engine Effects of Altitude and HeatDimensions 31.49 800 MMPage Installation Connecting the GroundOutdoor Installation Indoor InstallationPlacement Generator GroundingGeneral information GeneratorControl Box Control box is provided with the followingComponents generator 3 4 5 6 79700 This Honda engine is equipped with a low oilCircuit Breakers General Inspection Prior to Operation Ground Power ToolsExtension Cable Engine Oil Check Remove the dipstick from its holder and wipe cleanBefore Starting Battery Check Fuel CheckPlace the generators operation switch in the on position OperationBefore Starting the Engine Starting the EnginePlace main circuit breaker in the on position Place Gfci and AUX. circuit breakers in the on positionEmergency Shutdown Operation/shutdownStopping the Engine Normal Shutdown Preparation for long term storage Generator StorageMaintenance First EveryMaintenance DailyWeekly Engine Oil and FilterEngine Air Cleaner Engine Air CleanerGenerator wiring digram Wiring Color CodeTroubleshooting Engine Weak in power Water in fuel system? Recoil starterDirt? Malfunction Spiral spring loose? Replace spiral springTroubleshooting Generator Page Explanation of Code in Remarks Column Suggested Spare Parts To 3 unitsGA9.7HE- nameplate and decalS Assy Operating InstructionsA91110010 D25200040BB90400030 M90420000GA9.7HE Generator Assy Includes Items W/# RectifierFAN SET BOLT, RotorGA9.7HE Control BOX Assy Start Switch Control BOXTerminal Plate HEX, Head BoltGA9.7HE Pipe Frame Assy Battery Sheet Battery BandBattery Bolt Fuel Tank Includes Item W/#Honda GX610K1VD/U1VD AIR Cleaner Assy Clip AIR Cleaner Collar A, AIR CleanerFilter Outer BOLT, Special 5 MMHonda GX610K1VD/U1VD Engine Camshaft Assy SPRING, Weight Return SEAL, Valve StemCamshaft Assy ROD, PushHonda GX610K1VD/U1VD Engine Carburetor Assy TUBE, Breather CLIP, Breather TubeValve SET, Float Float SETHonda GX610K1VD/U1VD Engine Carburetor Assy GASKET, AIR Cleaner Valve ASSY., SolenoidINSULATOR, Carburetor GASKET, CarburetorHonda GX610K1VD/U1VD Engine Control Assy Joint ROD Spring StarterARM COMP., Governor ROD, GovernorHonda GX610K1VD/U1VD Engine Crankcase Cover Assy Weight Goernor HOLDER, Governor WeightPIN, Governor Weight BOLT, SealingHonda GX610K1VD/U1VD Engine Crankshaft Assy 90401ZJ1000 13310ZJ1880Crankshaft Comp Honda GX610K1VD/U1VD Engine Cylinder Barrel Assy COLLAR, Filter Setting PACKING, Breather CoverVALVE, Breather VALVE, OIL SHUT-OFFHonda GX610K1VD/U1VD Engine Cylinder Head Assy HANGER, Engine GUIDE, Intake Valve OSGUIDE, Exhaust Valve OS CLIP, Valve GuideHonda GX610K1VD/U1VD Engine FAN Cover Assy BRACKET, Wire Harness Clip CLIP, Wire Harness , BlackPLATE, R. Side PLATE, L. SideHonda GX610K1VD/U1VD Engine Flywheel Assy FAN, Cooling PULLEY, StarterGrid Screen SPACER, Starter Pulley MTHonda GX610K1VD/U1VD Engine Ignition Coil Assy GROMMET, High Tension Wire CAP ASSY., Noise SuppressorCoil ASSY., Charge 12V/3A Doide ASSY., Engine StopHonda GX610K1VD/U1VD Engine Piston Assy BOLT, Connecting ROD Ring SET, Piston STDPiston STD PIN, PistonHonda GX610K1VD/U1VD Engine Recoil Starter Assy PULLEY, Recoil Starter RATCHET, StarterSPRING, Friction SPRING, Starter ReturnHonda GX610K1VD/U1VD Engine Muffler Assy Muffler Comp PROTECTOR,MUFFLERSTAY, Muffler Band AssyHonda GX610K1VD/U1VD Engine Auto Throttle Assy Plate Solenoid Solenoid ASSY., RotaryNUT, Special CAP PURSE, LOCK, 8MMHonda GX610K1VD/U1VD Engine Starter motor Assy Switch ASSY., Magnet RING, SnapArmature Comp CLUTCH., OverrunningHonda GX610K1VD/U1VD Engine Fuel Pump Assy CLIP, Wire Harness Pump ASSY., FuelSTAY, Fuel Pump Tube COMP., Fuel aHonda GX610K1VD/U1VD Engine Rectifer Assy 31620881A02 Rectifer ASSY., RegulatorHonda GX610K1VD/U1VD- Engine Decals Assy Label Specification GX610 MARK, OIL ALERT, ExternalMARK, Fuel Warning MARK, Heat CautionHonda GX610K1VD/U1VD Engine Tool KIT Wrench COMP. Spark Plug HANDLE, BOX WrenchSapnner BAG ToolTerms and Conditions of Sale Parts FReigHT pOliCYPage HERE’S HOW to GET Help

ga-9.7HE specifications

The Multiquip GA-9.7HE is a high-performance generator that caters to the diverse needs of construction sites, industrial applications, and outdoor events. Engineered with robust features and advanced technologies, it stands out as a reliable power source in various environments.

One of the standout features of the GA-9.7HE is its powerful engine. Powered by a Honda gasoline engine, this generator delivers an impressive output of 9.7 kW, making it suitable for powering multiple tools and equipment simultaneously. The engine is designed for efficiency and durability, ensuring long operational hours with minimal maintenance requirements.

An integral component of the GA-9.7HE is its advanced inverter technology. This technology allows for cleaner, stable power output that is ideal for sensitive electronics and equipment. Whether it's powering construction tools or providing backup for electronics at an outdoor event, the inverter capability ensures optimal performance without risking damage to sensitive devices.

Additionally, the GA-9.7HE features a user-friendly control panel that provides easy access to essential functions. The control panel includes circuit breakers, output indicators, and start/stop controls, allowing operators to manage the generator efficiently. This ease of use is critical for ensuring seamless operation, especially in fast-paced work environments.

Portability is another key aspect of the GA-9.7HE. It is designed with a compact frame and comes equipped with heavy-duty wheels, making it easy to transport across job sites or during events. The lightweight construction also contributes to its mobility, allowing users to quickly reposition the generator as needed.

Safety features have not been overlooked in the GA-9.7HE. It includes automatic low-oil shutdown and circuit breaker protection, which help prevent engine damage and electrical issues. These safety measures are essential for maintaining the longevity of the generator and ensuring safe operation in various applications.

With a focus on reliability, efficiency, and versatility, the Multiquip GA-9.7HE is an excellent choice for those seeking a dependable power solution. Its combination of a powerful engine, advanced inverter technology, user-friendly design, and safety features makes it a valuable asset for contractors, event planners, and anyone in need of portable power.