Multiquip GA6HZR manual Rules for Safe Operation, General Safety

Page 6

CAUTION:

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the GA-6HZRGenerator:

GENERAL SAFETY

DO NOT operate or service this equipment before reading this entire manual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

This generator is a source of potentially LETHAL high voltage. Never permit unqualified personnel-especially children to operate the generator.

Always refuel in a well-ventilated area, away from sparks and open flames.

Always use extreme caution when working with flammable liquids. When refueling, stop the engine and allow it to cool. DO NOT smoke around or near the machine. Fire or explosion could result from fuel vapors, or if fuel is spilled on a hot engine.

This generator is equipped with a ground terminal for your protection. Always complete the grounding path from the generator to an external grounding source.

NEVER operate this generator, or handle any electrical equipment while standing in water, while bare foot, while hands are wet, or in the rain. Electrical shock could occur causing severe bodily harm or even death.

Keep electrical cords in good condition. Worn, bare or frayed wiring can cause electrical shock, leading to bodily harm or even death.

This generator requires an adequate free flow of cooling air. Never operate the generator in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the generator and may cause injury to people.

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing generator.

RULES FOR SAFE OPERATION

Provide adequate ventilation when operating the generator. DO NOT operate the generator in any enclosed or narrow space. The generator's gasoline engine gives off DEADLY carbon monoxide gas.

NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

Always make sure that the generator is secure on level ground so that it cannot slide or shift around, endangering workers. Also keep the immediate area free of bystanders.

When using a concrete vibrator or a similar device that is immersed in a water based solution, make sure the device is equipped with short circuit protection.

Always use rubber boots and gloves when operating a concrete vibrator or similar device.

Use adequate size connecting cable for extension.

Maintain electrical cords in good condition and frequently replace the entire cable of the concrete vibrator with a new one.

HighTemperatures – Allow the machine and engine to cool before adding fuel or performing service and maintenance functions. Contact with hot components can cause serious burns.

Emergencies

Always know the location of the nearest fire extinguisher and first aid kit. Know the location of the nearest telephone. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

Always allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source

PAGE 6 — GA-6HZR A.C. GENERATOR— OPERATION AND MANUAL — REV. #3 (03/30/11)

Image 6
Contents Model GA6HZR Proposition 65WARNING Page Table of Contents Parts Ordering Procedures Ordering parts has never been easierGeneral Safety Rules for Safe OperationOperation and Safety Decals Page GA-6HZR General Information GA-6HZR FamiliarizationGA-6HZR Controls and Indicators GA-6HZR Installation GA-6HZR PRE-SETUP General Inspection Prior to OperationFuel GA-6HZR Instrumentation Main Circuit Breaker 2-Pole 120/240V 60 HzGA-6HZR Load Application GA-6HZR Operating Instructions GA-6HZR Maintenance GA-6HZR Preparation for Long -TERM Storage Generator StorageGA-6HZR -WIRING Diagram GA-6HZR -TROUBLESHOOTING Engine GA-6HZR -TROUBLESHOOTING Engine GA-6HZR -TROUBLESHOOTING Generator GA-6HZR -TROUBLESHOOTING Generator GA-6HZR Explanation of Code in Remarks Column GA-6HZR Suggested Spare Parts To 5 UnitsGA-6HZR Generator Assy Rectifier Rotor ASS’YField Coil Surge AbsorberGA-6HZR Control BOX Assy GA-6HZR Control BOX Assy Control BOXGA-6HZR Pipe Frame Assy Base Pipe FrameBracket Rubber SuspensionGA-6HZR Muffler Assy GA-6HZR Muffler Assy MufflerGA-6HZR- Nameplate Assy Decal Warning Decal MQ GA-6HZRDecal Caution Decal DangerHonda GX340K1EDN2 Engine Cylinder Head Cover COMP., Head GUIDE, IN. Valve Over SizeCLIP, Valve Guide PACKING, Head CoverHonda GX340K1EDN2 Engine Recoil Starter SPRING, Friction PULLEY, Recoil StarterRATCHET, Starter SPRING, Starter ReturnHonda GX340K1EDN2 Engine FAN Cover Cover COMP., FAN ShroudClip Honda GX340K1EDN2 Engine CAMSHAFT/VALVES ROD, Push SPRING, Weight ReturnNUT, Pivot Adjusting ARM, Valve RockerHonda GX340K1EDN2 Engine PISTON/RINGS Piston STD Ring SET, Piston STDRing SET, Piston PIN, PistonHonda GX340K1EDN2 Engine AIR Cleaner SEAL, AIR Cleaner ELEMENT, AIR CleanerSTAY, AIR Cleaner Tube BreatherHonda GX340K1EDN2 Engine Cylinder Barrel Cylinder Barrel ASSY. Recoil StarterSHAFT, Governor ARM Switch ASSY., OIL LevelBarrel ASSY., Cylinder BOLT, Drain PlugCylinder Barrel ASSY. Electric Start 12000ZE3826 Honda GX340K1EDN2 Engine Crankcase COVER/GOVERNOR PACKING, Case Cover Honda GX340K1EDN2 Engine FLYWHEEL/FAN Assy Flywheel Comp FAN, CoolingPULLEY, Starter NUT, SPECIAL, 16 MMHonda GX340K1EDN2 Engine Coil Assy Coil ASSY., Ignition CLAMP, WireCORD, Stop Switch Coil ASSY., Lamp 12V/25WHonda GX340K1EDN2 Engine Crankshaft Assy WEIGHT, Balancer GEAR, Balancer DriveGEAR, Timing Honda GX340K1EDN2 Engine Governor Controls Assy Honda GX340K1EDN2 Engine Governor Controls Assy Honda GX340K1EDN2 Engine Carburetor Assy Gasket SET PACKING, AIR CleanerCLIP, Wire Harness Valve SET, FloatHonda GX340K1EDN2 Engine Solenoid Assy Solenoid Assy Honda GX340K1EDN2 Engine Fuel Cock Assy Filter CUP SCREEN, Fuel StrainerRing CUP, Fuel StrainerTerms and Conditions of Sale Parts Page HERE’S HOW to GET Help

GA6HZR specifications

The Multiquip GA6HZR is a versatile and robust diesel generator, designed to deliver reliable power in a variety of settings including construction sites, events, and emergency backup scenarios. It is particularly noted for its innovative engineering and high-performance capabilities, making it a preferred choice among professionals in need of dependable power solutions.

One of the key features of the GA6HZR is its powerful engine, which typically consists of a four-cylinder diesel engine that provides substantial output while maintaining fuel efficiency. This engine is engineered to produce an output of up to 6,000 watts, making it suitable for a variety of equipment and applications. The generator is also equipped with an automatic voltage regulator (AVR), ensuring a steady and consistent voltage supply, which is critical for sensitive electronic equipment.

Safety and durability are paramount in the design of the GA6HZR. The generator features a heavy-duty, weather-resistant enclosure that protects it from the elements, thereby enhancing its longevity. Additionally, it is designed to minimize noise levels, adhering to regulations for sound pollution without compromising performance. The built-in fuel tank has a large capacity, enabling extended run times between refueling, which is particularly advantageous for long-term operations.

Another significant characteristic of the Multiquip GA6HZR is its portability. The generator comes with rugged wheels and handles, making it easy to transport across job sites or between different locations. This level of mobility ensures that users can quickly deploy power wherever it is needed most.

In terms of technology, the GA6HZR incorporates advanced features such as hour meters and control panels that provide real-time information about the generator’s performance and operational status. This enhances user convenience and allows for proactive maintenance planning, ensuring that the generator operates efficiently for a longer duration.

Overall, the Multiquip GA6HZR stands out due to its powerful performance, robust construction, and user-friendly design. It is an excellent solution for those seeking a reliable, high-capacity generator that can handle demanding power needs across various applications. Whether for professional or emergency use, the GA6HZR remains a trusted choice in the generator market.