Multiquip DCA300SSCU manual HERE’S HOW to GET Help

Page 104

Operation and Parts Manual

HERE’S HOW TO GET HELP

PLEASE HAVE THE MODEL AND SERIAL

NUMBER ON-HAND WHEN CALLING

United StateS

Multiquip Corporate Office

 

MQ Parts Department

 

18910 Wilmington Ave.

Tel. (800) 421-1244

800-427-1244

Fax: 800-672-7877

Carson, CA 90746

Fax (800) 537-3927

310-537-3700

Fax: 310-637-3284

Contact: mq@multiquip.com

 

 

 

Service Department

 

Warranty Department

 

800-421-1244

Fax: 310-537-4259

800-421-1244

Fax: 310-943-2249

310-537-3700

 

310-537-3700

 

Technical Assistance

 

 

 

800-478-1244

Fax: 310-943-2238

 

 

mexico

 

United Kingdom

 

MQ Cipsa

 

Multiquip (UK) Limited Head Office

Carr. Fed. Mexico-Puebla KM 126.5

Tel: (52) 222-225-9900

Unit 2, Northpoint Industrial Estate,

Tel: 0161 339 2223

Momoxpan, Cholula, Puebla 72760 Mexico

Fax: (52) 222-285-0420

Globe Lane,

Fax: 0161 339 3226

Contact: pmastretta@cipsa.com.mx

 

Dukinfield, Cheshire SK16 4UJ

 

 

 

Contact: sales@multiquip.co.uk

 

Canada

 

 

 

Multiquip

 

 

 

4110 Industriel Boul.

Tel: (450) 625-2244

 

 

Laval, Quebec, Canada H7L 6V3

Tel: (877) 963-4411

 

 

Contact: jmartin@multiquip.com

Fax: (450) 625-8664

 

 

© COPYRIGHT 2011, MULTIQUIP INC.

Multiquip Inc and the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission.

This manual MUsT accompany the equipment at all times. This manual is considered a permanent part of the equipment and should remain with the unit if resold.

The information and specifications included in this publication were in effect at the time of approval for printing. Illustrations, descriptions, references and technical data contained in this manual are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifications, design or the information published in this publication at any time without notice and without incurring any obligations.

Your Local Dealer is:

Manufactured for

Multiquip Inc.

by

DENYO CO., LTD, JAPAN

Image 104
Contents Model dca300ssc Model dca300sscU Proposition 65 warning Reporting Safety Defects NhtsaTable of Contents DCA300SSC/DCA300SSCU 60 Hz GeneratorsChoose from three easy options Safety Information SaFetY meSSageSGeneral SaFetY Generator SaFetYIf operating in speed ranges above the maximum allowable Engine SaFetYRestricted. If the air fl ow is FUel SaFetY ToWing SaFetY„ never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot enginePower Cord/Cable Safety EleCtriCal SaFetYGrounding Safety BatterY SaFetY Environmental SaFetYSpecifications DCA300SSC/DCA300SSCUDimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Major Components Item noGenerator Control Panel Pilot Lamp Indicates the system is runningGenerator Control Panel Immediately cleaned or replaced Engine Operating PanelPage Output Terminal Panel is provided with the following Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds VAC Gfci Receptacles 240V Twist-Lock Auxiliary ReceptaclesConnecting Loads Over Current RelayLoad Application Single Phase LoadThree Phase Load Maximum Amps Generator Output VoltagesVoltage Change-Over Board How to Read the ac ammeter and ac voltage gauges Generator OUTPUTS/gauge readingAC Ammeter Gauge Reading AC Voltmeter Gauge ReadingUvwo Terminal Output Voltages 3Ø-240V Uvwo Terminal Output Voltages1Ø-240V Uvwo Terminal Output Voltages 1Ø-120V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages Inspection/SETUP Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/ Water Operation in Freezing WeatherBattery Battery Cable InstallationWiring AlternatorPlace the engine speed switch in the LOW down position Before StartingStarting Manual Engine’s exhaust contains harmful emissionsFrequency Meter Starting Auto Mode Before connecting this generator to anyPlace the engine speed switch in the High position Place the Mpec Control Switch in the Auto positionNever stop the engine suddenly except in an emergency Normal Shutdown ProcedureEmergency Shutdown Procedure Air Cleaner with Dust Indicator MaintenanceGeneral Inspection Air Cleaner Cleaning Inside the Fuel Tank Fuel AdditionRemoving Water from the Fuel Tank Fuel Tank InspectionRadiator Cleaning Check Oil LevelReplacing Oil Filter Flushing Out Radiator and Replacing CoolantBattery Charger and Jacket Water Heater Power Connections Coupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Brake Adjustment BrakesHydraulic Surge Brakes ActuatorSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramPage Troubleshooting Generator Troubleshooting Engine Controller Clean/repair radiator grillAdjust governor actuator Adjust governor controllerTroubleshooting Diagnostic lamp Method of OperationPage Explanation of Code in Remarks Column Suggested Spare Parts Generator Assy C2110000002 06018424020601823282 0018205020Generator Assy C3154400003 0017106015C3164600103 0010310030Control box Assy M5213000002 06018096590027106015 0601807513Control BOX Assy 38A 0601810244 06018316700601831205 0601830746Engine and Radiator Assy C2923200204 06020152440602046638 0602046639Engine and radiator Assy 0603306395 06020210700269200800 0602010220Engine operating panel Assy C2351101903 M53511000030017106020 0207006000Output terminal Assy C2231700403 M5230700003C0277500004 M9220100914Output terminal Assy 0016908020 C2237102403M5236100104 0019210030Battery ASSY. DCA300ssc 0165511551 C91091006043972250004 0805002904Battery ASSY. DCA300sscu 0602220196 M9310500404M9104000004 0602220921Muffler Assy C2331100002 M53301001020019210025 M5333000003Fuel tank Assy. DCA300ssc C2363000303 08101050040810105400 0264100525Fuel tank Assy. DCA300sscU M5363000202 06055050700605501069 M5364200004Enclosure Assy C2413003202 M5413000004C3414100104 M1413400004Enclosure Assy 0010114050 17A 003001400017B 0040014000 17C 0041214000Enclosure Assy M9114300004 8195146304M9114300104 0845050704Enclosure Assy 67A 0030006000 0845046904M9110100804 68A 0845045004Rubber Seals Assy 0228900650 02289007100229201300 0221200705Nameplate and Decals ASSY. DCA300ssc Remarks Nameplate and Decals ASSY. DCA300ssc Battery Group Nameplate and Decals ASSY. DCA300sscu M5550000303 Nameplate and Decals ASSY. DCA300sscU M9500300004 Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

DCA300SSCU specifications

The Multiquip DCA300SSCU is a powerhouse generator designed for both commercial and industrial applications, providing reliable performance in various environments. With a robust design and advanced technology, this generator stands out in the competitive field of portable power solutions.

One of the main features of the DCA300SSCU is its reliable diesel engine, which provides 300 kVA of power. The generator is powered by a fuel-efficient Yanmar engine, known for its durability and low emissions, making it an eco-friendly choice for users who need sustained power without sacrificing environmental standards. This engine is designed to operate efficiently, ensuring lower operational costs over time.

The DCA300SSCU boasts impressive electrical characteristics. It is equipped with a state-of-the-art automatic voltage regulator (AVR) that ensures voltage stability, protecting sensitive electronic equipment from damage due to voltage fluctuations. Additionally, the generator's output can be customized to meet specific needs, offering versatility for various applications ranging from construction sites to events.

This model integrates advanced noise reduction technology, making it quieter than many traditional generators on the market. An enclosed canopy design significantly dampens noise pollution, an essential feature for operation in urban areas or during nighttime events. This focus on reduced sound output allows for greater flexibility in deployment locations without disturbing nearby environments.

Ease of use and maintenance are other key characteristics of the DCA300SSCU. The generator features a user-friendly control panel that makes operation straightforward, even for individuals with minimal experience. Additionally, the maintenance intervals are designed to be manageable, reducing downtime and ensuring that the generator stays operational when it’s needed most.

In terms of mobility, the DCA300SSCU is designed with a trailer for easy transportation, allowing it to be moved from one job site to another with minimal effort. The robust frame and integrated lifting points ensure stability and safety during transit.

In summary, the Multiquip DCA300SSCU is a powerful, efficient, and versatile generator that meets the demands of numerous applications. With its dependable diesel engine, advanced voltage regulation, noise reduction mechanisms, and user-friendly design, it is an ideal choice for professionals seeking a high-performance power solution.