Multiquip DCA300SSCU C2331100002, M5330100102, 0019210025, M5333000003, 0602325066, C1334200304

Page 79

 

 

 

 

muffler ASSY.

 

 

 

 

 

NO.

PART NO.

PART NAME

QTY.

REMARKS

1

C2331100002

MUFFLER

1

DCA300SSC

1

M5330100102

MUFFLER

1

DCA300SSCU

2

0019210025

HEX HEAD BOLT

4

 

3

M5333000003

EXHAUST PIPE

1

 

4

0602325066

BEND BOLT CLAMP

1

 

5

C1334200304

GASKET

1

DCA300SSC

5

M4333200004

GASKET

1

DCA300SSCU

6

0010312055

HEX HEAD BOLT

4

 

6A

0030312000

HEX NUT

4

DCA300SSC

6B

0042512000

WASHER, LOCK

4

DCA300SSC

6C

0041612000

WASHER, FLAT

8

DCA300SSC

7

C2331300004

COVER

2

DCA300SSC

7

M5331300004

COVER

2

DCA300SSCU

8

0017108020

HEX HEAD BOLT

4

 

DCA300SSC / DCA300SSCU Gen. • operation and parts manual — rev. #1 (08/10/11) — page 79

Image 79
Contents Model dca300ssc Model dca300sscU Proposition 65 warning Nhtsa Reporting Safety DefectsDCA300SSC/DCA300SSCU 60 Hz Generators Table of ContentsChoose from three easy options SaFetY meSSageS Safety InformationGenerator SaFetY General SaFetYRestricted. If the air fl ow is Engine SaFetYIf operating in speed ranges above the maximum allowable From fuel vapors or if fuel is spilled on a hot engine FUel SaFetYToWing SaFetY „ never use fuel as a cleaning agentGrounding Safety EleCtriCal SaFetYPower Cord/Cable Safety Environmental SaFetY BatterY SaFetYDCA300SSC/DCA300SSCU SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Major ComponentsPilot Lamp Indicates the system is running Generator Control PanelGenerator Control Panel Engine Operating Panel Immediately cleaned or replacedPage Terminal legs O and Ground are considered bonded grounds Output Terminal FamiliarizationOutput Terminal Panel is provided with the following 240V Twist-Lock Auxiliary Receptacles VAC Gfci ReceptaclesOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadLoad Application Voltage Change-Over Board Generator Output VoltagesMaximum Amps AC Voltmeter Gauge Reading How to Read the ac ammeter and ac voltage gaugesGenerator OUTPUTS/gauge reading AC Ammeter Gauge Reading1Ø-120V Uvwo Terminal Output Voltages Uvwo Terminal Output Voltages3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages Fuel Check Inspection/SETUPCircuit Breakers Lubrication OilOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/ WaterAlternator BatteryBattery Cable Installation WiringEngine’s exhaust contains harmful emissions Place the engine speed switch in the LOW down positionBefore Starting Starting ManualFrequency Meter Place the Mpec Control Switch in the Auto position Starting Auto ModeBefore connecting this generator to any Place the engine speed switch in the High positionEmergency Shutdown Procedure Normal Shutdown ProcedureNever stop the engine suddenly except in an emergency General Inspection Air Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Cleaning Inside the Fuel TankFuel Addition Removing Water from the Fuel TankFlushing Out Radiator and Replacing Coolant Radiator CleaningCheck Oil Level Replacing Oil FilterBattery Charger and Jacket Water Heater Power Connections Trailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramPage Troubleshooting Generator Adjust governor controller Troubleshooting Engine ControllerClean/repair radiator grill Adjust governor actuatorMethod of Operation Troubleshooting Diagnostic lampPage Explanation of Code in Remarks Column Suggested Spare Parts Generator Assy 0018205020 C21100000020601842402 0601823282Generator Assy 0010310030 C31544000030017106015 C3164600103Control box Assy 0601807513 M52130000020601809659 0027106015Control BOX Assy 0601830746 38A 06018102440601831670 0601831205Engine and Radiator Assy 0602046639 C29232002040602015244 0602046638Engine and radiator Assy 0602010220 06033063950602021070 0269200800Engine operating panel Assy 0207006000 C2351101903M5351100003 0017106020Output terminal Assy M9220100914 C2231700403M5230700003 C0277500004Output terminal Assy 0019210030 0016908020C2237102403 M5236100104Battery ASSY. DCA300ssc 0805002904 0165511551C9109100604 3972250004Battery ASSY. DCA300sscu 0602220921 0602220196M9310500404 M9104000004Muffler Assy M5333000003 C2331100002M5330100102 0019210025Fuel tank Assy. DCA300ssc 0264100525 C23630003030810105004 0810105400Fuel tank Assy. DCA300sscU M5364200004 M53630002020605505070 0605501069Enclosure Assy M1413400004 C2413003202M5413000004 C3414100104Enclosure Assy 17C 0041214000 001011405017A 0030014000 17B 0040014000Enclosure Assy 0845050704 M91143000048195146304 M9114300104Enclosure Assy 68A 0845045004 67A 00300060000845046904 M9110100804Rubber Seals Assy 0221200705 02289006500228900710 0229201300Nameplate and Decals ASSY. DCA300ssc Remarks Nameplate and Decals ASSY. DCA300ssc Battery Group Nameplate and Decals ASSY. DCA300sscu M5550000303 Nameplate and Decals ASSY. DCA300sscU M9500300004 Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

DCA300SSCU specifications

The Multiquip DCA300SSCU is a powerhouse generator designed for both commercial and industrial applications, providing reliable performance in various environments. With a robust design and advanced technology, this generator stands out in the competitive field of portable power solutions.

One of the main features of the DCA300SSCU is its reliable diesel engine, which provides 300 kVA of power. The generator is powered by a fuel-efficient Yanmar engine, known for its durability and low emissions, making it an eco-friendly choice for users who need sustained power without sacrificing environmental standards. This engine is designed to operate efficiently, ensuring lower operational costs over time.

The DCA300SSCU boasts impressive electrical characteristics. It is equipped with a state-of-the-art automatic voltage regulator (AVR) that ensures voltage stability, protecting sensitive electronic equipment from damage due to voltage fluctuations. Additionally, the generator's output can be customized to meet specific needs, offering versatility for various applications ranging from construction sites to events.

This model integrates advanced noise reduction technology, making it quieter than many traditional generators on the market. An enclosed canopy design significantly dampens noise pollution, an essential feature for operation in urban areas or during nighttime events. This focus on reduced sound output allows for greater flexibility in deployment locations without disturbing nearby environments.

Ease of use and maintenance are other key characteristics of the DCA300SSCU. The generator features a user-friendly control panel that makes operation straightforward, even for individuals with minimal experience. Additionally, the maintenance intervals are designed to be manageable, reducing downtime and ensuring that the generator stays operational when it’s needed most.

In terms of mobility, the DCA300SSCU is designed with a trailer for easy transportation, allowing it to be moved from one job site to another with minimal effort. The robust frame and integrated lifting points ensure stability and safety during transit.

In summary, the Multiquip DCA300SSCU is a powerful, efficient, and versatile generator that meets the demands of numerous applications. With its dependable diesel engine, advanced voltage regulation, noise reduction mechanisms, and user-friendly design, it is an ideal choice for professionals seeking a high-performance power solution.