Multiquip operation manual GA-3.6RZ2 Instrumentation

Page 14

CAUTION :

When using a combination of dual receptacles, total load should not exceed the rated capacity of the generating.

Power Outlets

The generator has the following 120/240 volt 60 Hz (single- phase) receptacles.

λSingle Phase

One Duplex NEMA (GFCI) 5-20R (120V, 20 Amp) One Twist Lock NEMA L5-30R (120V, 30 Amp)

One Twist Lock NEMA L6-20R (240V, 20 Amp)

Main Circuit Breaker (2-Pole 120/240V 60 Hz)

This 2-pole 21 amp breaker protects the generator from short circuiting or overloading from the 120/240V 60 Hz single phase load.

Idle Control Switch

This unit is provided with an automatic idle control for noise suppression and reduced fuel consumption. The automatic idle control automatically engages under a no-load condition. With the automatic idle control switched “ON”, the engine revolutions will automatically drop to about 2600 rpm (low- speed operation) within 3 seconds after the load stops.When the operation is resumed, the engine speed is automatically increased to about 3600 rpm (high-speed operation) as soon as the load is connected.

Fuel Gauge

The fuel gauge is located on the fuel tank and allows easy monitoring of the fuel level.

AC Voltmeter

This voltmeter indicates (with a mark) the rated 60 Hz, single phase output voltage. In addition the voltmeter can also be used as a diagnostic tool.

If the voltmeter indicator (needle) is below the rated voltage, engine problems may exist (low/high RPM's). To prevent damage to the generator or power tools turn the generator OFF and consult your authorized Multiquip service dealer.

Operation Switch

This switch must be in the ON position (up) for normal operation.

GA-3.6RZ2 — INSTRUMENTATION

Start Switch

Push this switch to start the engine (electric start only). If a recoil starter is used, pull the starter rope to start the engine. Make sure the operation switch is in the ON position (up), otherwise engine will not start.

Full Power Switch

The unit is provided with a full power switch. Figures 2 and 3 show simplified wiring diagrams of the dual voltage system.

When the full power switch is in the 120 volt (up) position, you can take up full rated power of the generator at 120 volts from the single duplex receptacle, single locking type 120 volt receptacle, or a combination of these receptacles as long as the total load does not exceed the generating set capacity.

Figure 2. 120 V Simplified Diagram (Switch Up)

NOTE

When the full power switch is in the 120 volt position, the locking type 240 volt receptacle cannot be used.

When the full power switch is in the 240 volt (down) position, you can take up to half of the rated power of the generating set at 120 volts from the duplex receptacle and up to half of the rated power of the set at 120 volts from the locking type 120 volt receptacle; or full rated power of the set at 240 volts from the locking type 240 volt receptacle.

Figure 3. 240 V Simplified Diagram (Switch Dn.)

PAGE 14 — GA-3.6RZ2 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (03/05/01)

Image 14
Contents Multiquip Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures UPS Ground Service at no charge for freightEmergencies Maintenance SafetyRules for Safe Operation Operation and Safety Decals Machine Safety DecalsSpecifications Effects of Altitude and HeatControl Box GA-3.6RZ2 General InformationGenerator Excitation SystemGA-3.6RZ2 Controls and Indicators Outdoor Installation Indoor InstallationCircuit Breaker GA-3.6RZ2 PRE-SETUPGeneral Inspection Prior to Operation GroundLubrication Oil FuelGA-3.6RZ2 Instrumentation Single Phase Load GA-3.6RZ2 Load ApplicationWarm up Before StartingStarting OperationGA-3.6RZ2 Maintenance GA-3.6RZ2 Preparation for Long -TERM Storage Generator StorageGA-3.6RZ2 -WIRING Diagram Generator EngineGA-3.6RZ2 -TROUBLESHOOTING Engine GA-3.6RZ2 -TROUBLESHOOTING Engine WhiteGA-3.6RZ2 -TROUBLESHOOTING Generator Generator Troubleshooting Symptom Possible Problem SolutionGA-3.6RZ2 -TROUBLESHOOTING Generator GA-3.6RZ2 Explanation of Code in Remarks Column Items Found In the Items Number ColumnGA-3.6RZ2 Suggested Spare Parts To 5 Units To 10 UnitsGenerator Assy Field Coil GA-3.6RZ2 Control BOX Assy Machine Screw GA-3.6RZ2 Pipe Frame Assy HEX,HEAD Bolt GA-3.6RZ2 Name Plate and Decals See Decal Illustrations on Robin EH-25 Engine Crankcase Assy Part Name QTY Remarks Robin EH-25 Engine Crankshaft & Piston Assy NUT Robin EH-25 Engine Intake & Exhaust Assy Tappet Robin EH-25 Engine Governor Assy Governor Lever Robin EH-25 Engine Cooling & Starting Assy Label Trade Mark Robin EH-25 Engine Carburetor Assy Hose Clamp Robin EH-25 Engine Ignition Coil ASSY. and Spark Plug FLY Wheel Robin EH-25 Engine Fuel Strainer Robin EH-25 Engine Fuel Strainer Terms and Conditions of Sale Parts Freight PolicyPage Denyo Manufacturing CO., Japan Multiquip INC

GA-3.6RZ2 specifications

The Multiquip GA-3.6RZ2 is a highly versatile and robust generator that caters to various power needs, making it a reliable choice for construction sites, outdoor events, and emergency backup. This generator stands out for its impressive combination of power output, portability, and durability, ensuring that users have access to an uninterrupted power supply when required.

One of the key features of the GA-3.6RZ2 is its powerful engine. The generator is equipped with a reliable and fuel-efficient engine that delivers a maximum output of 3600 watts, making it suitable for running multiple tools and equipment simultaneously. This allows for efficient operation and strong performance in demanding environments. The engine also boasts a low noise level, making it suitable for use in noise-sensitive areas.

Portability is another significant aspect of the GA-3.6RZ2. Designed with a sturdy frame and integrated wheels, this generator is easy to move and transport, allowing users to take it wherever power is needed. Its compact design aids in saving space, whether it is being stored or deployed for use.

In terms of technology, the GA-3.6RZ2 incorporates advanced features that enhance its usability and reliability. It comes with intuitive controls that make it user-friendly, even for those who may not have extensive experience with generators. Additionally, the generator includes a built-in fuel gauge that allows users to monitor fuel levels easily, preventing unexpected shut-downs.

Durability is highlighted by the GA-3.6RZ2's rugged design, which is built to withstand harsh conditions often encountered on job sites. Its heavy-duty frame and high-quality components ensure that it can handle demanding tasks while providing long-lasting performance. The generator is also equipped with safety features such as circuit breakers that protect against overload and ensure safe operation.

The GA-3.6RZ2 functions efficiently in various applications, from powering electrical tools on construction sites to supplying backup power for critical home appliances during outages. With its combination of power, portability, user-friendly features, and durable construction, the Multiquip GA-3.6RZ2 is an ideal choice for users seeking reliability and performance in diverse power applications. In summary, this generator exemplifies Multiquip’s commitment to providing high-quality, dependable equipment for both professionals and casual users alike.