CAUTION:

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the GA-3.6RZ2 Generator:

GENERAL SAFETY

DO NOT operate or service this equipment before reading this entire manual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

This generator is a source of providing LETHAL high voltages. Never permit unqualified personnel-especially children to operate the generator.

Always refuel in a well-ventilated area, away from sparks and open flames.

Always use extreme caution when working with flammable liquids. When refueling, stop the engine and allow it to cool. DO NOT smoke around or near the machine. Fire or explosion could result from flames or sparks, or if fuel is spilled on a hot engine.

This generator is equipped with a ground terminal for your protection. Always complete the grounding path from the generator to an external grounding source.

NEVER operate this generator, or handle any electrical equipment while standing in water, while bare foot, while hands are wet, or in the rain. Dangerous electrical shock could occur causing severe bodily harm or even death.

Keep electrical cords in good condition. Worn, bare or frayed wiring can cause electrical shock, thus causing bodily harm or even death.

This generator requires an adequate free flow of cooling air. Never operate the generator in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the generator and may cause injury to people.

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing generator.

RULES FOR SAFE OPERATION

Provide adequate ventilation when operating the generator. DO NOT operate the generator in any enclosed or narrow space. The generator's gasoline engine gives off DEADLY monoxide gas.

NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

Always make sure that the generator is secure on level ground so that it cannot slide or shift around, endangering workers. Also keep the immediate area free of bystanders.

CAUTION:

High Temperatures – Allow the machine and engine to cool before adding fuel or performing service and maintenance functions. Contact with hot components can cause serious burns.

CAUTION:

Emergencies

Always know the location of the nearest fire extinguisher and first aid kit. Know the location of the nearest telephone. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

Always allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

PAGE 6 — GA-3.6RZ2 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (03/05/01)

Image 6
Contents Multiquip Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures UPS Ground Service at no charge for freightMaintenance Safety Rules for Safe OperationEmergencies Operation and Safety Decals Machine Safety DecalsSpecifications Effects of Altitude and HeatControl Box GA-3.6RZ2 General InformationGenerator Excitation SystemGA-3.6RZ2 Controls and Indicators Outdoor Installation Indoor InstallationCircuit Breaker GA-3.6RZ2 PRE-SETUPGeneral Inspection Prior to Operation GroundLubrication Oil FuelGA-3.6RZ2 Instrumentation Single Phase Load GA-3.6RZ2 Load ApplicationWarm up Before StartingStarting OperationGA-3.6RZ2 Maintenance GA-3.6RZ2 Preparation for Long -TERM Storage Generator StorageGA-3.6RZ2 -WIRING Diagram Generator EngineGA-3.6RZ2 -TROUBLESHOOTING Engine GA-3.6RZ2 -TROUBLESHOOTING Engine WhiteGA-3.6RZ2 -TROUBLESHOOTING Generator Generator Troubleshooting Symptom Possible Problem SolutionGA-3.6RZ2 -TROUBLESHOOTING Generator GA-3.6RZ2 Explanation of Code in Remarks Column Items Found In the Items Number ColumnGA-3.6RZ2 Suggested Spare Parts To 5 Units To 10 UnitsGenerator Assy Field Coil GA-3.6RZ2 Control BOX Assy Machine Screw GA-3.6RZ2 Pipe Frame Assy HEX,HEAD Bolt GA-3.6RZ2 Name Plate and Decals See Decal Illustrations on Robin EH-25 Engine Crankcase Assy Part Name QTY Remarks Robin EH-25 Engine Crankshaft & Piston Assy NUT Robin EH-25 Engine Intake & Exhaust Assy Tappet Robin EH-25 Engine Governor Assy Governor Lever Robin EH-25 Engine Cooling & Starting Assy Label Trade Mark Robin EH-25 Engine Carburetor Assy Hose Clamp Robin EH-25 Engine Ignition Coil ASSY. and Spark Plug FLY Wheel Robin EH-25 Engine Fuel Strainer Robin EH-25 Engine Fuel Strainer Terms and Conditions of Sale Parts Freight PolicyPage Denyo Manufacturing CO., Japan Multiquip INC

GA-3.6RZ2 specifications

The Multiquip GA-3.6RZ2 is a highly versatile and robust generator that caters to various power needs, making it a reliable choice for construction sites, outdoor events, and emergency backup. This generator stands out for its impressive combination of power output, portability, and durability, ensuring that users have access to an uninterrupted power supply when required.

One of the key features of the GA-3.6RZ2 is its powerful engine. The generator is equipped with a reliable and fuel-efficient engine that delivers a maximum output of 3600 watts, making it suitable for running multiple tools and equipment simultaneously. This allows for efficient operation and strong performance in demanding environments. The engine also boasts a low noise level, making it suitable for use in noise-sensitive areas.

Portability is another significant aspect of the GA-3.6RZ2. Designed with a sturdy frame and integrated wheels, this generator is easy to move and transport, allowing users to take it wherever power is needed. Its compact design aids in saving space, whether it is being stored or deployed for use.

In terms of technology, the GA-3.6RZ2 incorporates advanced features that enhance its usability and reliability. It comes with intuitive controls that make it user-friendly, even for those who may not have extensive experience with generators. Additionally, the generator includes a built-in fuel gauge that allows users to monitor fuel levels easily, preventing unexpected shut-downs.

Durability is highlighted by the GA-3.6RZ2's rugged design, which is built to withstand harsh conditions often encountered on job sites. Its heavy-duty frame and high-quality components ensure that it can handle demanding tasks while providing long-lasting performance. The generator is also equipped with safety features such as circuit breakers that protect against overload and ensure safe operation.

The GA-3.6RZ2 functions efficiently in various applications, from powering electrical tools on construction sites to supplying backup power for critical home appliances during outages. With its combination of power, portability, user-friendly features, and durable construction, the Multiquip GA-3.6RZ2 is an ideal choice for users seeking reliability and performance in diverse power applications. In summary, this generator exemplifies Multiquip’s commitment to providing high-quality, dependable equipment for both professionals and casual users alike.