Multiquip operation manual DCA-150SSJU3 Safety Message Alert Symbols, Hazard Symbols

Page 8

DCA-150SSJU3 — SAFETY MESSAGE ALERT SYMBOLS

FORYOUR SAFETY AND THE SAFETY OF OTHERS!

HAZARD SYMBOLS

Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.

This Owner's Manual has been

developed to provide complete

NOTE instructions for the safe and efficient operation of the MQ Power Model DCA-150SSJU3

Whisperwatt™ Generator.

Before using this generator, ensure that the operating individual has read and understands all instructions in this manual.

SAFETY MESSAGE ALERT SYMBOLS

The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION.

DANGER

You WILL be KILLED or SERIOUSLY injured if you do not follow directions.

WARNING

You COULD be KILLED or SERIOUSLY injured if you do not follow directions.

CAUTION

You CAN be injured if you do not follow directions

Potential hazards associated with the operation of this equipment will be referenced with "Hazard Symbols" which appear throughout this manual, and will be referenced in conjunction with Safety "Message Alert Symbols".

WARNING - LETHAL EXHAUST GASES

Gasoline engine exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause DEATH if inhaled. NEVER operate this

equipment in a confined area or enclosed structure that does not provide ample free flow air.

WARNING - EXPLOSIVE FUEL

Gasoline is extremely flammable, and its vapors can cause an explosion if ignited. DO NOT start the engine near spilled fuel or combustible fluids. DO NOT fill the fuel tank while the engine is running or hot.

DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system. Store fuel in approved containers, in well-ventilated areas and away from sparks and flames. NEVER use fuel as a cleaning agent.

WARNING - BURN HAZARDS

Engine components can generate extreme heat.To prevent burns, DO NOT touch these areas while the engine is running or immediately after operations. NEVER operate the engine with heat shields or heat guards removed.

DANGER - ELECTROCUTION HAZARDS

During operation of this generator, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

PAGE 8 — DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07)

Image 8
Contents Parts List NO. M3870301104 Model DCA-150SSJU32 DCA-150SSJU3- Operation and Parts Manual REV. #0 11/14/07 Heres HOW to GET Help Wilmington Ave Carson, CATable of Contents Parts Ordering Procedures When ordering parts Please supply the following informationDCA-150SSJU3 Specifications DCA-150SSJU3 Dimensions TOP, Side and Front DimensionsDCA-150SSJU3 Safety Message Alert Symbols Hazard SymbolsDCA-150SSJU3 Safety Message Alert Symbols This generator, other property, orGeneral Safety DCA-150SSJU3 Rules for Safe OperationGenerator Grounding Electrical SafetyDCA-150SSJU3 Rules for Safe Operation Maintenance Safety Battery SafetyTowing &Transporting Safety EmergenciesDCA-150SSJU3 Generator Decals DCA-150SSJU3 Generator Decals Generator Decals Cont inuedDCA-150SSJU3 Installation Typical Generator Grounding ApplicationDCA-150SSJU3 Installation Outdoor InstallationIndoor Installation When connecting the generatorGenerator Engine Operating PanelGenerator Control Panel Output Terminal PanelDCA-150SSJU3 Major Components Major ComponentsMenu Button Press this button to enter or exit menu screens Display ParametersDCA-150SSJU3 Diagnostic Display First Time Start UpMain Menu Navigation Selecting a LanguageDiagnostic Code Stored Fault CodesEngine Configuration Data To make a selectionDCA-150SSJU3 Diagnostic Display 24 DCA-150SSJU3- Operation and Parts Manual REV. #0 11/14/07 Auxiliary Gage Fault Display will return to the single or four parameter screenActive Fault Codes Backlight Adjustment Shut Down CodesCode from an engine control unit the single or four DamageIs highlighted Contrast AdjustmentIntensity Setup 1- Up Display Select UnitsUp display function Once the Setup 1-up Display menu icon has beenSetup menu Automatic Scan on Setup 4-Up Display Select the 4-Up Custom Setup from the 4-Up Setup menuUtilities information and troubleshooting When the gage data has cleared, the display Gage Data is selected the PowerView willVersion currently in the diagnostic display Half duplexTouch the Menu Button Highlight it, then touch Enter Touch the Menu button again to return to the MainMenu DCA-150SSJU3 Diagnostic Display Glossary Troubleshooting informationECU did not respond to the PowerView request No parameter selected for this 4- UP quadrantDCA-150SSJU3 Generator Control Panel DCA-150SSJU3 Engine Operating Panel Fuel Gauge Indicates amount of diesel fuel availableDCA-150SSJU3 Engine Operating Panel Auto On/Off Engine Controller MpecDCA-150SSJU3 Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-150SSJU3 Output Terminal Panel Familiarization 120VAC Gfci ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadDCA-150SSJU3 Load Application Motors and motor-drivenGenerator OutputVoltages Voltage Change-Over BoardGenerator Amperage 120V 240VHow to Read the Output Terminal Gauge Change-Over SwitchDCA-150SSJU3 Generator OUTPUTS/ Gauge Reading Maximum AmpsThree-Phase Position DCA-150SSJU3 Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages DCA-150SSJU3 Output Terminal Panel Connections3Ø 480/277 Output Terminal Lug Voltages DCA-150SSJU3 Setup Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure RefuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze Operation FreezingWeatherBattery Battery Cable InstallationWiring AlternatorDCA-150SSJU3 Generator START-UP Procedure Manual Place the engine speed switch in the LOW down positionBefore Starting Engines exhaust contains harmful emissionsEngine Speed Switch High Starting Auto Mode When the generator is set Auto mode, the generator willNo Load Tachometer GaugePlace the engine speed switch in the High position Place the Mpec Control Switch in the Auto positionEmergency Shutdown Procedure DCA-150SSJU3 Generator SHUT-DOWN ProceduresNormal Shutdown Procedure DCA-150SSJU3 Maintenance Engine Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterDCA-150SSJU3 Maintenance HEATER/CHARGER To ensure adequate startingDCA-150SSJU3 Maintenance Trailer Trailer MaintenanceDCA-150SSJU3 Maintenance Trailer Brake AdjustmentBrakes Check the wheel and drum for free rotationSuspension Tires/Wheels/Lug NutsTireWear/Inflation Start all wheel lug nuts by hand DCA-150SSJU3 Maintenance TrailerLug Nut Torque Requirements DCA-150SSJU3 -TRAILERWIRING Diagram DCA-150SSJU3 Generatorwiring Diagram Generator Wiring DiagramDCA-150SSJU3 Enginewiring Diagram DCA-150SSJU3 -TROUBLESHOOTING Generator Generator TroubleshootingDCA-150SSJU3 -TROUBLESHOOTING Engine Controller Engine Controller Troubleshooting MpecDCA-150SSJU3- Operation and Parts Manual REV. #0 11/14/07 Sample Parts List DCA-150SSJU3 Explanation of Code in Remarks ColumnPart number on this Suggested Spare Parts list DCA-150SSJU3 Suggested Spare PartsDCA-150SSJU3 Generator Assy C0110000112 Includes Item W8131070013 8131611014DCA-150SSJU3- Control BOX Assy M3213001602 03300002100330000240 0330000180DCA-150SSJU3- Control BOX ASSY. M3270100304 M3213601904M3213602004 37A 0330000275DCA-150SSJU3- Engine and Radiator Assy M3923200084 R521052RE504836 RE529643DCA-150SSJU3- Engine and Radiator ASSY. 0603306590 06033002850605511395 0603306395DCA-150SSJU3- Outputterminal Assy Output Terminal AssyM3230700003 M9220100304M9220100404 0039316000DCA-150SSJU3- Battery Assy 0602220196 M9310500404M9103000504 0602220921DCA-150SSJU3- Muffler Assy M3330100502 0016910025M3333001303 M3333200104DCA-150SSJU3- Fueltank Assy M3363001902 06055050700605501076 0605516090DCA-150SSJU3- Enclosure Assy Enclosure AssyM3413002302 M1413400004M3423002502 M3493111903DCA-150SSJU3- Enclosure ASSY. Enclosure ASSY.33A 0041206000 M91130000020021806016 35A 003000600094 DCA-150SSJU3- Operation and Parts Manual REV. #0 11/14/07 63A M9116100004 M911010030464A M9116100004 0601850097DCA-150SSJU3- Rubber Seals Assy 0229201200 02289010050228901090 0228901150DCA-150SSJU3- Nameplate and Decals Assy M3550003003 M9520100304M9520100603 M3550002803DCA-150SSJU3- Nameplate and Decals ASSY. M9510200002 06005000900021106016 M3560100903Payment Terms DCA-150SSJU3- Operation and Parts Manual REV. #0 11/14/07 Your Local Dealer is

DCA-150SSJU3 specifications

The Multiquip DCA-150SSJU3 is a powerful, reliable diesel generator that is designed to meet the demanding energy needs of various applications, including construction sites, events, and emergency power supply. With its robust construction and advanced technology, the DCA-150SSJU3 stands out in the competitive market of portable generators.

One of the main features of the DCA-150SSJU3 is its impressive output capabilities. This generator generates a continuous output of 150 kVA, which is more than enough to power multiple tools and equipment simultaneously. It is equipped with a high-quality, efficient diesel engine that not only delivers ample power but also ensures fuel efficiency, reducing operational costs over time.

The design of the DCA-150SSJU3 prioritizes user convenience and operational efficiency. It is fitted with a digital control panel that provides real-time monitoring of critical parameters such as voltage, frequency, and operating hours. This user-friendly interface simplifies the process of managing power output and helps operators maintain optimal performance.

Moreover, the DCA-150SSJU3 is equipped with advanced soundproofing technology, making it one of the quieter models in its class. This feature is particularly beneficial in environments where noise regulations must be adhered to, such as residential areas or during nighttime operations.

Durability is another key characteristic of the Multiquip DCA-150SSJU3. The generator is housed in a robust steel enclosure that protects it from external elements, ensuring longevity and reliable performance even in challenging conditions. Additionally, the generator has been designed with easy service access in mind, facilitating maintenance procedures and minimizing downtime.

Safety is paramount in generator design, and the DCA-150SSJU3 does not fall short in this aspect. It is equipped with a comprehensive range of safety features, including low oil shut-off, overload protection, and emergency stop buttons, ensuring safe operation for users.

In conclusion, the Multiquip DCA-150SSJU3 is a versatile and resilient diesel generator that excels in performance, efficiency, and safety. With its powerful output, advanced technologies, and user-friendly design, it is an ideal choice for those needing reliable power solutions across various demanding environments. Whether for temporary applications or as an emergency backup, the DCA-150SSJU3 is a generator that offers peace of mind and dependable performance.