Vector 1000 WATT, VEC095 owner manual Specification s, Appendix a Battery Installation

Page 17

11 . S p e c i f i c a t i o n s :

Jump-Start Clamps

400 Amps - Heavy Duty Copper

Jumper Cables

9mm2 Welding Cable

Battery

User-Supplied 12 Volt, Group 27 size. Sealed Lead-Acid

Flourescent Lamp

8 Watt Fluorescent Tube

Dual Accessory Socket Protection

30 Amp Self-Resetting Breaker

Power Inverter

1000 Watt,15 minutes, 800 watt continuous, 60 Hz, 110-120 VAC

Power Inverter Momentary Peak

2000 Watts

Inverter Waveform

Modified Sine Wave

Inverter DC Input Range

10.0 to 15.5 VDC

Inverter Low Battery Audible Alarm

10.6 VDC

Automatic Shutdown

. ..................................

Low Voltage, Overload, Over Temperature

Compressor

Max Pressure, 300 PSI

Pressure Gauge Type

................................................................................

Analog Dial

Air Delivery

9kg /cm

Operating temp

-20°C to +80° C

Motor current

9 Amps

Dimensions

20ÓH x 20ÓW x 18ÓD (50.8cm x 50.5cm x 45.72)

Weight

30 lbs without battery (11.2 Kg)

Appendix A – Battery Installation

In most cases, the seald lead-acid battery is installed by the user. The battery is easily installed using the provided hardware. The user will need a medium Phillips head screwdriver and a wrench to do the battery installation.

CAUTION: MAKE SURE THE RED (POSITIVE) CABLE CONNECTS TO THE POS (+) BATTERY TERMINAL AND THE BLACK (NEGATIVE) CABLE CONNECTS TO THE NEG (Ð) TERMINAL.

Reverse connections will cause damage and void the warranty.

NOTE: The inverter is attached to the battery compartment cover. The inverter is not separated from the cover during battery installation. The battery compartment cover is removed by unscrewing (counterclock-wise) two Phillips head screws located on the left and right forward corners of the cover. The two inverter terminal covers (red and black) are unsrcewed (counterclock-wise) and lifted off. (See Figures A1 and A2) Remove the lock washer on each terminal. The entire inverter and battery compartment cover are carefully lifted and placed on a flat stable surface. The battery compartment should contain the battery clamp adapter cable and the universal terminal adapter. Remove any items from the battery compartment. Lift the two cables out of the way so they are not down inside the battery compartment. Carefully lower the battery into the battery compartment. The terminals on the battery can be one of several types. The user should take the supplied universal connector and configure it to adapt the cable ends to the battery posts. Make sure all connections are mechanically tight. Replace the inverter and battery compartment cover. Replace the two Phillips screws and the lock washers and terminal covers. Make sure the red and black covers are on the correct terminals.

17

Image 17
Contents VEC095 Volt AC, 12 Volt DC Portable Power SupplyJump-Start Warnings and Cautions Important Safety InstructionsApplications N t e n t sN T R O D U C T I O N General Jump-Start Cables and Protection Applications Additional Key FeaturesJump-start Procedure Using ElectroMate Jump-StartInverter Operation USEPrinciples of Operation Use with AppliancesOperating Time Powering an AC LoadPlacement of ElectroMate Operating Tips Troubleshooting the InverterCompressor/Tire Compressor Use Compressor Safety InformationInflation of tire or products with a valve stem Typical inflation timesInflating Items Without a a Tire Stem FluorescentRecharging DC Recharge AC RechargeBattery Maintenance/ReplacementBattery Disposal Warnings Simultaneous Recharge and Inverter OperationAppendix a Battery Installation Specification sExtending Operating Time Appendix Battery InstallationAppendix B Symptom Troubleshooting Appendix CYear Limited Warranty Registrationform