Master Lock MGR2900A, MGR4500I, MGR6000I Storage, Servicing the Engine, Technical Service

Page 14

R

PORTABLE GASOLINE GENERATORS

STORAGE

WARNING:Removeallfuelfrom fuel tank before storing generator. Store fuel in approved container. Storefuelinawell-ventedareafree of open flames or sparks.

WARNING: The muffler be- comes very hot during operation. The muffler remains hot for a while after shutdown. Let engine cool before storing.

IMPORTANT: Keepgeneratorlevelwhilein storage. Never store generator upside down or standing on end.

Note:We supply the engine owner’s manual with generator. Refer to that manual for questions concerning engine storage.

Use a fuel additive, such as STA-BIL®or an equivalent, when storing generator with fuel in fuel tank. This will minimize fuel gum deposits from forming in engine.

Cover and store generator in a clean, dry place. Do not expose generator to extreme high or low temperatures during storage.

SERVICING THE ENGINE

Robin parts and services should be handled by your nearest authorized engine service firm. Visit:

www.robinamerica.com

or call Robin direct:

1-800-277-6246

TECHNICAL

SERVICE

You may have further questions about as- sembling, operating, or maintaining this product. If so, you can visit our Technical Service web site at www.desatech.com or contact our Technical Service Department at 1-800-858-8501 (English Only).You may also write to:

DESA Specialty Products™

ATTN: Technical Service Specialty Products P.O. Box 90004

Bowling Green, KY 42102-9004

When contacting DESA Specialty Prod- ucts™, have ready

Your Name

Your Address

Your Phone Number

• Model Number of Product

Serial Number

• Date of Purchase (Include copy of receipt

 

for written requests).

TROUBLESHOOTING

Note: For additional help, visit DESA Specialty Products’™ technical service web site at www.desatech.com.

WARNING: Only a qualified electrical service person should service and repair generator. Use only factory approved replacement parts.

Note: See engine owner’s manual for engine troubleshooting.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

No voltage when starting generator with no

1.

Loss of residual magnetism

1.

Apply 12-volt battery to capacitor ter-

electrical load

 

 

 

minals for 2-3 seconds

 

2.

Winding short circuit or loose

2.

Check resistance of coils (see Electrical

 

 

connections

 

Component Specifications, page 15)

 

3.

Defective rotor diode

3.

Replace both diodes on rotor

 

4.

Defective capacitor

4.

Replace capacitor

 

 

 

 

 

Voltage is less than normal voltage with no

1.

Engine speed too low

1.

Set engine speed to 3800 RPM (63 Hz)

electrical load

 

 

 

with no load

 

2.

Defective rotor diode

2.

Replace both diodes on rotor

 

3.

Partial short circuit in winding

3.

Check resistance of coils (see Electrical

 

 

 

 

Component Specifications, page 15)

 

4.

Defective capacitor

4.

Replace capacitor

 

 

 

 

 

Voltmeter reading more than 10% high with

1.

Engine speed too high

1.

Set engine speed to 3800 RPM (63 Hz)

no electrical load

 

 

 

with no load

 

 

 

 

 

Voltmeter reading correct with no electrical

1.

Defective rotor diode

1.

Replace both diodes on rotor

load, but more than 10% low when electrical

2.

Electrical load too high

2.

Do not overload generator

load is added

3.

Engine not running properly

3.

Contact an authorized engine service

 

 

 

 

center

www.desatech.com

14

118679

Image 14
Contents Portable Gasoline Generators Safety Information Portable Gasoline GeneratorsProduct Identification If it produces smoke or flamesUnpacking High and LOW Temperature OperationGeneral Information VentilationMGR2900A MGR4500I MGR6000I SpecificationsModel OIL Alert System Generator FeaturesVoltage Selector Switch AUTO-IDLE SystemReceptacle Circuit Breaker Engine OILFuel Checking OIL Level and Adding OILExtension Cords Standby Installation to Home or BuildingRecommended Minimum Wire Gauges AWG for Extension Cords Generator GroundingDetermining Electrical Load for Generator Chart 1 Typical Electric Appliance WattagesChart Operation Using ReceptaclePower Cord and Plug Requirements General InformationPrestart StartingAdjusting the Idle Speed Models MGR4500I MGR6000I AUTO-IDLE OperationHigh Altitude Operation Adding Electrical Loads Maintenance and RepairsDisconnecting Electric Loads Stopping EngineStorage Technical ServiceTroubleshooting Servicing the EngineCapacitor Electrical Component SpecificationsWiring Diagrams ModelWiring Diagram, Models MGR4500I and MGR6000I KEY Part Number Description QTY Illustrated Parts ListFor Model MGR2900A Alternator Assembly Parts Available not ShownMGR4500I MGR6000I For Models MGR4500I MGR6000I Alternator AssemblyKEY Part Number for Model Description QTYFor Model MGR2900A Roll Cage For Models MGR4500I MGR6000I Fuel Tank Roll Cage InformFor Models MGR4500I MGR6000I Fuel Tank and Roll Cage KEYFor Models MGR4500I MGR6000I Control Panel Warranty Service Replacement Parts and AccessoriesRepair Service NON-WARRANTY ServiceWarranty Information Keep this Warranty

MGR2900A, MGR4500I, MGR6000I specifications

Master Lock has long been synonymous with security, providing reliable and durable locks to ensure peace of mind. Among its diverse product range, the Master Lock MGR2900A, MGR4500I, and MGR6000I stand out due to their advanced features and design.

The Master Lock MGR2900A is a versatile combination padlock that offers convenience and security. With a customizable four-digit combination, users can enjoy the ease of access while maintaining privacy. Its solid steel construction ensures strength and durability, while a weather-resistant cover protects it from environmental factors, making it suitable for both indoor and outdoor use. The MGR2900A's compact size makes it ideal for securing lockers, gates, and storage units, providing users with a reliable locking solution in various scenarios.

Moving up in capability, the Master Lock MGR4500I is equipped with innovative technology designed to maximize security. This electronic bike lock employs a Bluetooth connection, allowing users to lock and unlock the device directly from their smartphones. The MGR4500I features a built-in alarm system that activates upon attempted tampering, deterring potential thieves. Its sturdy construction, combined with a rechargeable battery that can last for weeks, makes it a popular choice for cyclists. Additionally, the app provides access to usage history and alerts, giving users complete control over their lock's functionality.

Finally, the Master Lock MGR6000I exemplifies the pinnacle of electronic security. This smart lock integrates seamlessly with home automation systems, allowing users to control access remotely. Offering fingerprint recognition and smartphone connectivity, the MGR6000I ensures quick yet secure entry—ideal for busy households. Its sleek design complements modern aesthetics while providing robust security measures, including a backup key option for emergencies. The lock's weather-resistant features make it resilient against the elements, ensuring reliable performance year-round.

In summary, the Master Lock MGR2900A, MGR4500I, and MGR6000I each provide unique features suited for different security needs. From customizable combinations and Bluetooth connectivity to advanced smart technology, these locks exemplify Master Lock’s commitment to innovation and quality, making them ideal choices for anyone seeking dependability and peace of mind.