Check the wall channel and jamb is vertical. Loosen screws ‘A’ to adjust from side to side.

Re-tighten screws

A

STEP

18

If the any further adjustment is required to make

the glass panel vertical turn the 4 screws ‘D’

until the panel is in the correct position

D

STEP

20

10 CFI230G

The edge of the glass should fit against the end of the slot in the tray ‘B’. To adjust the glass loosen the 4 screws ‘C’ and move the panel until it is the correct postion. Re-tighten screws

C

Check end of glass is vertical

B

STEP

19

Measure the distance of the glass between

the wall jamb and the tray ‘A’. Cut the

splashguard to size cutting at the wall jamb end.

Fit the splashguard to the bottom of the glass

A

STEP

21

COMMISSIONING

1.General

1.1.Turn on the water supply to the Digital Mixer.

1.2.Check for leaks over the complete system.

1.3.Turn on the electrical supply to the Digital Mixer.

For the Pumped Version with the Slider Rail Shower System, pump priming can be helped by removing the handset and lowering the end of the hose into the shower tray.

2. Set the Maximum Temperature

Note! The maximum temperature of the unit can only be set when the unit has not been used for a period of 10 minutes.

2.1.Temperature Selection - Set the temperature control knob to the desired position, as per the table below.

Temperature Control

Temperature Selection oC

Knob Position

 

 

 

1

Factory Set 45

 

 

2

39

 

 

3

40

 

 

4

42

 

 

5

43

 

 

6

44

 

 

7

45

 

 

7.5

46

 

 

8

47

 

 

9

48

 

 

2.2.Enabling - Press and momentarily hold the Warm Up and High keys at the same time. Release the push-button and reselect within 2 seconds. The two keys will flash twice and beep three times to confirm the selection is successful.

3.Lock Mode

Note! Allows you to lock the unit during operation.

3.1.Selection - Press and momentarily hold the Warm Up and Medium keys at the same time. The two keys will flash twice and beep three times to confirm the selection is successful.

3.2.Operation - This mode locks out all the keys except the Warm Up/Off key. It also locks the temperature control knob. Once selected it is only possible to turn the unit OFF.

Selecting Warm Up/Off and Medium at the same time again, cancels the lock mode.

CFI230G 19

Image 10
Contents Indigo Quadrant Enclosure Kohler Daryl LimitedCustomer Service Kohler Daryl and Kohler MiraDaryl Care Programme Cleaning ComponentsTroubleshooting Malfunction Cause RemedyHandset Adjustment Enclosure InstallationFixed Head Adjustment Spray Settings Spray PlateWarm Up Function Optional OperationTo Operate the Shower Timeout Temperature Control Timeout Minutes Knob PositionLock Mode Set the Maximum TemperatureTemperature Control Temperature Selection oC CommissioningFit top cap Water delivery side Fixed Head Water Delivery Only Important do not Over TightenSlider Rail Water Delivery Only Bottom Entry Top Entry

CFI230G specifications

The Kohler CFI230G is a remarkable addition to the landscape of powerful and efficient small engines, primarily designed for various applications ranging from lawn and garden equipment to light construction machinery. One of the standout features of the CFI230G is its robust 230cc engine, designed to deliver exceptional performance while maintaining fuel efficiency. The engine is equipped with a high performance, gasoline-fueled design that ensures durability and reliability under diverse working conditions.

At the heart of the CFI230G lies its overhead valve (OHV) configuration, which enhances the engine's efficiency and allows for smoother operation. This technology not only contributes to better fuel economy but also reduces emissions, making it an environmentally friendly choice for users who require dependable power sources. Moreover, the engine is designed with an integrated cooling system that helps maintain optimal operating temperatures, further improving its overall efficiency.

Another notable feature is the electric start mechanism, which simplifies the starting process. Users can easily engage the engine with the push of a button, eliminating the frustration often associated with recoil starting systems. Complementing this is Kohler's advanced fuel system, which includes a reliable fuel pump that provides consistent fuel delivery, ensuring that the engine runs smoothly even at varying speeds and loads.

Durability is a critical aspect of the Kohler CFI230G, built with a cast-iron cylinder that withstands wear and tear over time. This design leads to a longer life for the engine, making it an economical choice for both commercial and residential applications. The maintenance of the CFI230G is also user-friendly with accessible oil fill and drain ports, enabling quick and easy servicing.

The CFI230G is equipped with innovative noise-reduction technologies that ensure quieter operation compared to some of its competitors, providing a more pleasant working environment. Additionally, the engine's compact design allows for versatility in installation and compatibility across various equipment.

In conclusion, the Kohler CFI230G blends power, efficiency, and durability, making it an ideal choice for users who require a reliable engine for their lawn, garden, or light industrial applications. With features designed for ease of use and long-lasting performance, the CFI230G continues to establish Kohler as a leader in small engine technology.