Knoll GRS44 Supported Commands, Function Command Range Read/Write Remarks

Page 8

8

Supported Commands

Command Summary

 

 

 

 

 

# = numerical zone or amplifier channel value

 

 

 

 

$$ = second numerical value (may be one or two digits)

 

 

 

Function

Command

Range

Read/Write

Remarks

Version

(vr?)

none

read only

 

Reset

(rx)

none

write only

1 second

Channel On

(#on)

1-4

write only

 

Channel Off

(#of)

1-4

write only

 

Mute

(#mu)

1-4

write only

 

Un-mute

(#um)

1-4

write only

Note 3

Mute All

(amu)

none

write only

Note 3

Un-mute All

(aum)

none

write only

 

Volume Request

(#vl?)

1-4

read only

 

Volume Set

(#vl$$)

1-4 / 0-87

write only

 

Volume All

(avl$$)

0-87

write only

 

Input Request

(#sl?)

1-4

read only

 

Input Set

(#sl$)

1-4 / 1-4

write only

 

Input Select All

(asl$)

1-4

write only

 

All Channels On

(aon)

none

write only

 

All Channels Off

(aof)

none

write only

Note 3

All Channels Vol up

(avlu)

none

write only

Note 1

All Channels Vol dn

(avld)

none

write only

Note 1

Channel Vol up

(#vlu)

1-4

write only

Note 1

Channel Vol down

(#vld)

1-4

write only

Note 1

Bass adjustment

(#b$)

1-4 / 0-F

write only

Note 2

Treble adjustment

(#t$)

1-4 / 0-F

write only

Note 2

Display treble

(#b?)

1-4

read

only

 

Display bass

(#t?)

1-4

read

only

 

Note1: Volume up or down requests increase or decrease volume level by 5

Note 2: Treble and bass commands use hexadecimal values 0-F, default (flat) is 8.

Note3: After “ALL Channels Off” command an “Un-mute” must be sent to each channel to restore a channel volume.

Also, it is best to leave about a ½ second between commands, as some integrators may miss commands if they are entered too quickly.

All commands also send a message back to the terminal after they have been completed, so that it is easy to keep track of the previous commands that were sent.

Note: Some commands are read or write only and some are both – for example: Mute All is a write only command and Version is a read only command.

Supported Command Messages

Function

Command

Message

Version

(vr?)

Version Number

Reset

(rx)

“Resetting...”

Channel On

(#on)

“Zone # on”

Channel Off

(#of)

“Zone # off“

Mute

(#mu)

“Zone # muted”

Un-mute

(#um)

“Zone # unmuted”

Mute All

(amu)

"All channels muted"

Image 8
Contents GRS44 Important Safety Instructions FCC Warning CanadaGRS44 is controlled by RS232 commands Input connections GRS44 placementConnecting your amplifier Speaker connections RS232 Connection Supported Command Messages Function Supported CommandsFunction Command Range Read/Write Remarks Knoll Systems service information Troubleshooting Care, maintenance, and cleaningMade in Canada