Husqvarna 420 GN manual Contact with muffler area can result in serious burns

Page 6

WARNING

Generator produces hazardous voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Contact with muffler area can result in serious burns.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot parts and AVOID hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

WARNING

Starter and other rotating parts can entangle hands, hair, clothing, or accessories.

NEVER operate generator without protective housing or covers.

DO NOT wear loose clothing, jewelry or anything that may be caught in the starter or other rotating parts.

Tie up long hair and remove jewelry.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

NOTICE

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

DO NOT exceed the generator’s wattage/amperage capacity. See Don’t Overload Generator in the Operation section.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

NOTICE

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or contact local service center.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

6

www.usa.husqvarna.com

Image 6
Contents Operator’s Manual Where to Find Us Generator Date PurchasedTable of Contents Safety alert symbol is used with a signal word Operator SafetySafety Rules Hazard Symbols and MeaningsEngine exhaust from this product contains Broken bones, fractures, bruises, or sprains could resultWhen Testing for Engine Spark Contact with muffler area can result in serious burnsUnintentional sparking can result in fire or electric shock Unpack Generator AssemblyInstall Wheel Kit Add Engine OilGenerator Location Connecting to a Building’s Electrical SystemSystem Ground Special RequirementsFuel Valve Used to turn fuel supply on and off to engine Features and ControlsVolt DC batteries Items Not ShownVolt DC Accessory Jack Cord Sets and ReceptaclesVolt AC, 15 Amp, Duplex Receptacle Starting the Engine Connecting Electrical LoadsOperation Stopping the EngineTo recharge 12 Volt batteries, proceed as follows Charging a BatteryCold Weather Operation PositiveCreating a Temporary Shelter An emergency, use the original shipping cartonCreating a Permanent Shelter Don’t Overload Generator Wattage Reference GuideEngine Maintenance MaintenanceGenerator Maintenance CleaningLong Term Storage Instructions StorageGenerator Storage Storing the EngineTroubleshooting Husqvarna Portable Generator Owner Warranty Policy Product Specifications 877Exploded View Main Unit Exploded View Main Unit Parts List Main Unit DescriptionParts Not Illustrated Exploded View and Parts List Alternator

420 GN specifications

The Husqvarna 420 GN is a powerful and versatile garden tool designed to meet the needs of both professional landscapers and dedicated gardening enthusiasts. This robust chainsaw boasts a range of advanced features and technologies that enhance its performance, ensuring efficient and effective cutting in various outdoor tasks.

One of the standout features of the Husqvarna 420 GN is its powerful engine, which provides a remarkable power-to-weight ratio. The excellent performance is complemented by a low vibration design, allowing extended periods of use without discomfort. The chainsaw is equipped with a centrifugal air cleaning system that significantly reduces the amount of debris and dust entering the air filter. This ensures longer operating periods between air filter cleanings and contributes to the overall longevity of the equipment.

The intuitive design of the Husqvarna 420 GN leads to excellent maneuverability. Its lightweight construction allows users to easily handle the chainsaw during various cutting applications, improving efficiency and precision. The front and rear handles are ergonomically designed, providing a secure grip that enhances control, particularly during demanding cutting tasks.

The chainsaw features an X-Torque engine technology, which minimizes fuel consumption and emissions while maintaining high levels of power. This emphasizes Husqvarna’s commitment to sustainability without compromising performance. Additionally, the chainsaw is equipped with an automatic oil pump that optimizes chain lubrication based on usage, ensuring the chain is always properly lubricated for optimal cutting performance.

The chainsaw is also designed for easy maintenance, with a tool-less chain tensioning system that allows users to adjust the chain tension quickly and efficiently without the need for additional tools. The sturdy construction of the Husqvarna 420 GN, coupled with its ideal size for various cutting tasks, makes it a favorite among professionals and avid gardeners alike.

Overall, the Husqvarna 420 GN is an exceptional choice for those seeking a reliable and powerful chainsaw. With its combination of advanced technologies, ergonomic design, and ease of maintenance, it sets a high standard in the world of outdoor power equipment, making it a valuable addition to any toolkit. Whether tackling heavy-duty jobs or handling lighter pruning tasks, the Husqvarna 420 GN delivers excellence in performance and reliability.