•If electrolyte gets on your skin, flush with water.
•If electrolyte gets in your eyes, flush with water for at least 15 minutes and call a physician immediately.
•Electrolyte is poisonous. If swallowed, drink large quantities of water or milk and follow with milk of magnesia or vegetable oil and call a physician.
•To prevent the possibility of creating a spark near the battery, connect charging cables first to the battery, then to the generator. Disconnect cables first at the generator.
Note. Never leave the DC plug in the generator when not using the DC for charging batteries. Always remove the DC plug from the socket. In most cases it is acceptable to use both the 12V DC for battery charging and the
AC 240V outlet at the same time. However, when the generator is working close to the maximum load, the generator may go into over load where the AC load will need to be reduced or disconnected.
Generator maintenance
Your generator should be kept clean and dry at all times. The generator should not be stored or operated in environments that includes excessive moisture, dust or any corrosive vapours. If these substances are on the generator, clean with a cloth or soft bristle brush. Do not use a garden hose or anything with water pressure to clean the generator. Water may enter the cooling air slots and could possibly damage the rotor, stator and the internal windings of the generator head.
Storage
If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage.
Never store the generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliances.
Maintenance schedule
Item | Remarks | Each use | First month | Every 3 months | Every 6 months | Every Year |
|
|
| or 10Hrs | or 50Hrs | or 100Hrs | or 300Hrs |
|
|
|
|
|
|
|
Engine oil | Check | • |
|
|
|
|
Change |
| • |
| • |
| |
|
|
|
| |||
Air cleaner | Check | • |
|
|
|
|
|
|
|
|
|
| |
Clean |
|
| • (2) |
|
| |
|
|
|
|
| ||
Spark plug |
|
|
| • |
| |
|
|
|
|
|
|
|
Spark arrester | Clean |
|
|
| • |
|
Fuel sediment cup | Clean |
|
|
| • |
|
Valve clearance |
|
|
|
| • (3) | |
|
|
|
|
|
|
|
Fuel tank & strainer | Clean |
|
|
|
| • (3) |
Fuel line | Check |
| Every 2 Years (Replace if necessary)(3) |
|
It is recommended that you keep a log of the hours of operation to determine correct maintenance requirements. Generators that are used in dusty conditions/areas should be serviced more frequently. All servicing should be conducted by an authorized service agent.