SAFETY & WARNING INSTRUCTIONS
MAINTENANCE
15. | Before each use, thoroughly |
| inspect your unit for loose or |
| damaged parts. Do NOT use until |
| adjustments or repairs have been |
| made. |
16. | All attachments must be installed |
| properly before operating the unit, |
| such as debris collector bag. |
17. | Keep all bystanders especially pets |
| and children at least fifty (50) feet |
| from the unit while using. |
18. | To avoid unintentionally starting of |
| the unit, do NOT carry |
| unit with your finger on the switch. |
| Be sure the unit is unplugged. |
19. | Always remain alert and use |
| common sense when using this |
| unit. To prevent injury to yourself |
| and to others, NEVER use the |
| leaf blower when your are tired. |
20. | DO NOT operate this unit while |
| under the influence of drugs, |
| alcohol or medication. |
21. | Do NOT over reach or use the leaf |
| blower from unstable surfaces such |
| as ladders, trees, steep slopes, |
| rooftops, etc. Keep proper footing and |
| balance at all times. |
22. | Wear heavy, long pants, boots, |
| gloves and a long sleeve shirt. Do |
28.To reduce the risk of electrical shock, this unit has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord. This unit plug will fit into a polarized extension cord only one way. If the plug does not fit, obtain a correct polarized extension cord. A polarized extension cord requires the use of a polarized wall outlet. This plug will fit into a polarized wall outlet only one way. If the plug does not fit, contact a qualified electrician to install the proper
wall outlet. Do NOT change the unit plug, extension cord receptacle or extension cord plug in any way.
29.When using an extension cord, make sure that it is a cord that is heavy enough to carry the current that your unit will draw. An undersized extension cord will cause a drop is line voltage resulting in loss of power and overheating. The table below shows the correct size to use depending on the cord length and amperage rating.
WARNING
Removing Debris from Clogged Impeller
1.Turn off and unplug the vacuum from the power source and wait for all moving parts to stop.
2.Remove the easy grip handle, or the inlet cover.
3.Remove blockage. If necessary dislodge blockage with a wooden stick.
4.Check the impeller for any signs of damage. If damage to any parts have occurred contact customer service at 1 (800)
5.Install the vacuum tube or, if you want to switch to blower mode see instructions for correct procedure.
Cleaning Bag and Tubes
Best performance is achieved with proper cleaning and maintenance.
1.Unplug unit from power source, and ensure all parts have stopped moving.
2.Empty bag according to instructions on page 10.
3.To clean bag, turn inside out and hose down the bag.
4.Air dry for 24hrs.
5.Do Not install onto unit until bag is completely dry.
6.To clean tubes, remove from unit first, then use a hose to clear grass or leaves stuck inside of tubes.
WARNING: Never douse or squirt motor with water or any other liquid.
Keep handles and tubes dry, clean and free from debris.
Storage of Leaf Blower
1.Store unit and extension cord in a indoors.
2.Keep out of reach of children.
3.Tubes can be stored upright after assembly, however ensure that there are no sharp objects that can damage tubes.
4.Do not store tubes under any other items. This can cause permanent dents in the tubes.
NOT wear loose clothing, jewelry, |
short pants sandals or go barefoot. |
Secure hair above shoulder level. |
23. Always turn switch off when |
vacuuming or blowing is delayed or |
when changing locations. Always |
inspect new locations before |
operating. |
24. To reduce the risk of electrical |
shock, use only with an extension |
cord intended for outdoor use such as |
|
25. Ground Fault Circuit Interrupter |
(GFCI) protection should always be |
provided on electrical circuits or |
outlets to be used for this unit. |
26. To reduce the risk of electrical shock, |
use only with a two conductor |
extension cord intended for outdoor |
use. |
27. Never connect the unit to an AC |
voltage that differs from the one on |
the unit’s rating plate. |
2
To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch the plug with wet hands.
| Extension Cord Length | ||||
| 25' | 50’ | 100’ | 150’ | |
AMPERAGE | WIRE SIZE (AWG) | ||||
RATING | |||||
|
|
|
| ||
18 | 16 | 14 | 12 | ||
|
|
|
|
|
30.Keep impeller clean of vegetation and other foreign materials. Cooling air inlets may become clogged with debris. Overheating the unit can increase risk of fire or injury.
31.When using the unit, always hold the unit with both hands. Keep a firm grip on the front handle and on the top handle.
TROUBLESHOOTING
TROUBLESHOOTING GUIDE
SYMPTOM |
| CAUSE |
| REMEDY | |
| 1. | Switch in the OFF | 1. | Move switch to ON position. | |
| 2. | position. | |||
Unit fails to operate | Extension cord | 2. | Reconnect extension cord. | ||
3. | disconnected | 3. | Reset circuit breaker or fuse. | ||
| Circuit breaker | 4. | Contact FANTOM Customer | ||
| 4. | tripped, or fuse blown. |
| Service at 1 (800) | |
| Mechanical failure. |
|
| ||
|
|
|
|
| |
Unit vibrates | 1. | Mechanical failure. | 1. | Contact FANTOM Customer | |
| Service at 1 (800) | ||||
abnormally | 2. | Blockage to parts. |
| ||
2. | Inspect unit for blockage. | ||||
|
|
| |||
|
|
|
|
| |
Impeller will not turn | 1. | Debris in air intake | 1. | Unplug and clear unit of debris. | |
| area. | 2. | Contact FANTOM Customer | ||
freely |
| ||||
2. | Mechanical failure. |
| Service at 1 (800) | ||
|
| ||||
|
|
|
|
|
11