Emerson CF759OB00 warranty MaintenanceAccessories, Trouble Shooting

Page 9

Authorized Emerson Fan Dealer www.NovaLightingStore.com 800-860-1207

MaintenanceAccessories

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.

Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.

!WARNING

Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.

1.Ceiling Fan Light Kits (see store or catalog).

2.Downrod Kits (see store or catalog).

!WARNING

The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage.

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

 

1. Fan will not start.

1.

Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit

 

 

 

 

breakers.

 

2.

Loose power line connections to the fan, or loose

2.

Check line wire connections to fan and switch

 

 

switch wire connections in the switch housing.

 

wire connections in the switch housing.

 

 

 

!

WARNING: Make sure main power is turned off.

 

3.

Reversing switch in neutral position.

3.

Make sure reversing switch position is all the way

 

 

 

 

to one side.

 

 

 

 

 

2. Fan sounds noisy.

1.

Blades not attached to fan.

1.

Attach blades to fan before operating.

 

2.

Loose screws in motor housing.

2.

Check to make sure all screws in motor housing

 

 

 

 

are snug (not over-tight).

 

3.

Screws securing fan blade flanges to motor hub

3.

Check to make sure the screws which attach

 

 

are loose.

 

the fan flanges to the motor hub are tight.

 

4.

Switch housing binding against blade hub.

4.

Check to make sure that the switch housing

 

 

 

 

does not bind against the blade hub.

 

5.

Wire connectors inside switch housing rattling.

5.

Check to make sure wire connectors in

 

 

 

 

switch housing are not rattling against each

 

 

 

 

other or against the interior wall of the switch

 

 

 

 

housing.

 

 

 

!

WARNING: Make sure main power is turned off.

 

6.

Motor noise caused by solid-state variable

6.

Some fan motors are sensitive to signals from

 

 

speed control.

 

Solid-State variable speed controls. If Solid-

 

 

 

 

State Control is used and motor noise results

 

 

 

 

choose an alternative control method.

 

7.

Screws holding blades to flanges are loose.

7.

Tighten screws securely.

 

 

 

 

 

3. Fan wobbles

1.

Screws securing fan blade flanges to motor hub

1.

Check to be sure screws which attach the fan

excessively.

 

are loose.

 

blade flanges to the motor hub are tight.

 

2.

Fan blade flanges not seated properly.

2.

Check to be sure the fan blade flanges seat

 

 

 

 

firmly and uniformly to the surface of the motor

 

 

 

 

hub. If flanges are seated incorrectly, loosen the

 

 

 

 

flange screws and retighten according to the

 

 

 

 

procedure in the section on "How to Put Your

 

 

 

 

Ceiling Fan Together".

 

3.

Hanger bracket and/or ceiling outlet box is not

3.

Tighten the hanger bracket screws to the outlet

 

 

securely fastened.

 

box, and/or secure outlet box.

 

4.

Fan blades out of balance.

4.

Interchanging an adjacent (side-by-side) blade

 

 

 

 

pair can redistribute the weight and result in

 

 

 

 

smoother operation.

 

 

 

 

 

9

Emerson Fans Available at www.NovaLightingStore.com 800-860-1207

Image 9
Contents Read and Save These Instructions Safety Instructions Unpacking Instructions Tools Needed for AssemblyHow to Put Your Ceiling Fan Together Electrical Requirements How to Wire Your Ceiling Fan How to Hang Your Ceiling FanSetting Transmitter Frequency Setting Remote Control Operating FrequencyOperation of Your Remote Control Using Your Ceiling FanTrouble Shooting MaintenanceAccessoriesAir Comfort Products Repair Parts Listing
Related manuals
Manual 10 pages 52.73 Kb

CF759OB00 specifications

The Emerson CF759 series ceiling fans, comprising models CF759PB00, CF759AB00, CF759WW00, CF759TG00, and CF759OB00, represent a pinnacle of versatility and performance in residential ceiling fans. With a focus on functionality and aesthetics, these fans are designed to enhance comfort while contributing to the overall decor of any room.

One of the main features of the Emerson CF759 models is their sleek and aerodynamic blade design, which ensures optimal airflow and energy efficiency. The fans come equipped with powerful motors that provide high performance while minimizing noise, making them perfect for bedrooms, living rooms, and other spaces where peace and quiet are essential.

Another notable characteristic of the CF759 series is their range of finishes. Each model boasts a unique color schemeā€”PB00 features polished brass, AB00 showcases antique bronze, WW00 is styled in a modern white finish, TG00 offers a traditional textured globe, and OB00 presents an elegant oil-rubbed bronze. This variety allows homeowners to select a fan that best complements their interior design.

The CF759 models incorporate advanced technologies, including multiple speed settings and a reversible motor function. This versatility enables users to adjust airflow to their liking, whether they need a gentle breeze in the summer or assistance with air circulation during cooler months. The reversible feature allows the fan blades to spin in either direction, effectively distributing warm air during winter and cool air in summer.

Additionally, the Emerson CF759 fans are designed with ease of installation in mind. They come with all necessary hardware and a straightforward setup process, making installation a breeze for both seasoned DIYers and those who may not be as handy.

Finally, these ceiling fans are compatible with various control options, including wall switches and remote controls, adding to the convenience and user-friendliness of the overall design.

In summary, the Emerson CF759PB00, CF759AB00, CF759WW00, CF759TG00, and CF759OB00 ceiling fans blend style, efficiency, and practicality, making them an ideal choice for anyone looking to enhance their living space. The combination of advanced features and appealing designs ensures that these models will meet diverse consumer needs while providing reliable, year-round comfort.