Authorized Emerson Fan Dealer www.NovaLightingStore.com 800-860-1207

SUPPLY

BLACK AND BLUE

FAN WIRES

GROUND

WIRE

 

LISTED

WHITE SUPPLY

WIRE

CONNECTOR (3)

(NEUTRAL)

GREEN WIRE

 

(GROUND) FROM

WHITE FAN

HANGER BRACKET

WIRE

GREEN WIRE

BLACK SUPPLY

(GROUND) FROM

(HOT)

HANGER BALL

 

 

 

NOTE: CEILING COVER

 

 

OMITTED FOR CLARITY.

Figure 12

 

 

 

 

 

 

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

3.Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.

4.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 13).

5.Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 13). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.

CEILING COVER

Setting Remote Control Operating Frequency

Your Emerson Remote Control Fan receiver and transmitter can be set to operate at one of 16 different frequencies. In most cases you will not need to change the factory set frequency. The frequency should only need to be changed for one of the following reasons:

a. Multiple fans in one location that you wish to operate from one transmitter. (ALL fans should be set at the same frequency.)

NOTE: Your Emerson Remote Control is designed to operate from a distance up to 20 feet from the fan. If you are operating multiple fans with one transmitter you should be no more than 20 feet from any of the fans to ensure that all fans will respond at the same time.

b. Multiple fans in one location that you wish to operate from different transmitters. (ALL fans set to different frequencies.)

c. Interference with other household systems such as your garage door opener.

NOTE: If you change the operating frequency, you must change both the transmitter and receiver to the same frequency. The remote control will not operate unless both the transmit- ter and receiver are set at the same frequency.

Setting Transmitter Frequency

1.Remove battery cover and the battery from the transmitter. Locate the switch with four levers numbered 1, 2, 3, 4, just above the battery compartment (See Figure 14).

THREADED STUD LOCKWASHERS (2) KNURLED KNOB

Figure 13

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

2.With a narrow blade screwdriver, change the position of one or more of the four levers on the switch. Note the positions of each of the four levers by number; down is ON, up is OFF.

Setting Receiver Frequency

1.After electricity has been turned off at the main fuse box, remove the switch housing assembly by removing the three mounting screws (See Figure 6).

2.Disconnect the switch housing connector form the motor connector by squeezing the latch and pulling the connectors apart.

3.Remove the receiver from the switch housing and locate the switch with four numbered levers (same as transmitter). (See Figures 14 and 15).

4.Set the position of all four levers, ON or OFF to the same position as those on the transmitter.

5.Install the receiver in the switch housing, push the motor connector into the switch housing connector and assemble the switch housing assembly to the housing plate (See Figures 5 and 6).

7

Emerson Fans Available at www.NovaLightingStore.com 800-860-1207

Image 7
Contents Read and Save These Instructions Safety Instructions Unpacking Instructions Tools Needed for AssemblyHow to Put Your Ceiling Fan Together Electrical Requirements How to Wire Your Ceiling Fan How to Hang Your Ceiling FanSetting Transmitter Frequency Setting Remote Control Operating FrequencyOperation of Your Remote Control Using Your Ceiling FanTrouble Shooting MaintenanceAccessoriesAir Comfort Products Repair Parts Listing
Related manuals
Manual 10 pages 52.73 Kb

CF759OB00 specifications

The Emerson CF759 series ceiling fans, comprising models CF759PB00, CF759AB00, CF759WW00, CF759TG00, and CF759OB00, represent a pinnacle of versatility and performance in residential ceiling fans. With a focus on functionality and aesthetics, these fans are designed to enhance comfort while contributing to the overall decor of any room.

One of the main features of the Emerson CF759 models is their sleek and aerodynamic blade design, which ensures optimal airflow and energy efficiency. The fans come equipped with powerful motors that provide high performance while minimizing noise, making them perfect for bedrooms, living rooms, and other spaces where peace and quiet are essential.

Another notable characteristic of the CF759 series is their range of finishes. Each model boasts a unique color schemeā€”PB00 features polished brass, AB00 showcases antique bronze, WW00 is styled in a modern white finish, TG00 offers a traditional textured globe, and OB00 presents an elegant oil-rubbed bronze. This variety allows homeowners to select a fan that best complements their interior design.

The CF759 models incorporate advanced technologies, including multiple speed settings and a reversible motor function. This versatility enables users to adjust airflow to their liking, whether they need a gentle breeze in the summer or assistance with air circulation during cooler months. The reversible feature allows the fan blades to spin in either direction, effectively distributing warm air during winter and cool air in summer.

Additionally, the Emerson CF759 fans are designed with ease of installation in mind. They come with all necessary hardware and a straightforward setup process, making installation a breeze for both seasoned DIYers and those who may not be as handy.

Finally, these ceiling fans are compatible with various control options, including wall switches and remote controls, adding to the convenience and user-friendliness of the overall design.

In summary, the Emerson CF759PB00, CF759AB00, CF759WW00, CF759TG00, and CF759OB00 ceiling fans blend style, efficiency, and practicality, making them an ideal choice for anyone looking to enhance their living space. The combination of advanced features and appealing designs ensures that these models will meet diverse consumer needs while providing reliable, year-round comfort.