Emerson CF3100AGW00 owner manual Setting Operating Frequency of Wall Control Receiver Figure

Page 11

Setting Operating

Frequency of Wall Control

and Receiver (Figure 21)

Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and

4)on the switches are factory-set in the ON (up) position. Change the switch settings as follows:

1.Slide the four switch levers in the wall control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.

2.In the receiver, slide the four switch levers to the same positions as set in the wall control. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate.

Installation

of Wall Control

WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box.

The SW116 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW116 wall control to function. Power for the SW116 wall control comes from the 12V battery, located in the wall control.

Replacement 12V batteries recommended are Duracell MN21, Eveready A23, and GP23A.

1.Install the 12V battery (supplied) into the wall control (Figure 22).

2.The SW116 wall control is supplied with a white, ivory, or almond color cover. Choose the style that best suits your needs and snap the cover onto the wall control (Figure 22).

SW105 RECEIVER

CODE SWITCH

ON

1

2

3

4

RECEIVER SWITCH LEVERS

ON

1

2

3

4

WALL CONTROL LEVERS

 

HIHI

 

U/L

MMED

LIGHT

 

 

 

LOWLOW

REVREV

 

 

D/L

FAN OFF

 

 

 

WALL

12V BATTERY

CONTROL

 

HIHI

 

MEMDED

LIGHT

 

LOLWOW

RREVEV

 

FAN OFF

 

SW116 WALL

COVER

SW116 WALL

Figure 22

CONTROL

 

3.

Install the wall control onto the outlet box using the

 

supplied screws (Figure 23).

4.

Install decorator wall plate (purchased separately)

CONTROL

Figure 21

CODE SWITCH

using the two screws provided with wall plate.

Leave wall control in “OFF” mode until fan

installation is completed (Figure 23).

DECORATIVE WALL PLATE

OUTLET BOX

(Purchased Separately)

 

 

 

 

 

U/L

 

 

HI

 

 

 

 

LIGHT

 

 

MED

 

 

 

 

D/L

 

 

LOW

REV

 

 

FAN OFF

 

 

 

 

SW116 WALL

 

WALL PLATE

 

CONTROL

 

WALL CONTROL

Figure 23

SCREW (2)

SCREW (2)

11

 

 

U.L. Model No.: CF3100

Image 11
Contents Dunnington Safety Instructions Unpacking Instructions Tools Needed for AssemblyElectrical Requirements Preliminary ProceduresCeiling Fan Assembly Procedures Model No. CF3100 ONE-PIN How to Hang Your Ceiling Fan Ceiling Cover White FAN Wire Wire Connector How to Wire Your Ceiling FanOutlet BOX Hanger Bracket Switch Cover Installation Light Kit InstallationInstallation Wall Control Setting Operating Frequency of Wall Control Receiver FigureInstruction to the User if device contains a digital device Operating Your Ceiling FanTrouble Shooting MaintenanceAccessories Repair Parts Receiver, Remote Control SW105 Repair Parts ListingLimited Warranty