Echo PE-266/S specifications Blade Replacement

Page 26

MAINTENANCE

PE-266/S

 

 

Blade Replacement

Level 1.

Parts Required:

Blade, new split pin

Note: Replace blade when it is bent, damaged, or worn shorter than 6 inches.

1. Remove split pin (A).

G

2.

Align hole in inner blade adapter (B) with notch in gear

B

 

housing, and insert locking tool (G) to prevent PTO shaft (C)

 

 

 

from rotating.

C

3.

Remove L.H. blade nut (D) by turning clockwise. Remove

 

 

outer blade adapter (E), and blade (F).

F

4. Install and center blade (F) on inner blade adapter (B).

5. Install outer adapter (E) and nut (D). Tighten nut (D) firmly,

E

turning counterclockwise.

D

Note: Never reuse old split pin.

A

6.Install new split pin (A) to secure nut, and bend both legs of pin counterclockwise around PTO shaft (C).

26

X7502026303

© 6/2014 ECHO Inc.

Image 26
Contents Operator’s Manual Burn HazardTable of Contents Introduction Servicing InformationManual Safety Symbols and Important Information SafetyAdditional or Replacement Manuals International Symbols On / OFFPersonal Condition and Safety Equipment Vibration and Cold Repetitive Stress InjuriesEquipment Product Emission Durability Emission Compliance Period Emission Control Exhaust & EvaporativeEPA 2010 and Later and/or C.A.R.B. Tier Description Description Contents Throttle Linkage and Ignition Leads AssemblyDrive Shaft/Power Head Assembly Support HandleFuel Requirements OperationFuel Handling FuelAfter use Starting Cold Engine Purge BulbStarting Warm Engine Stopping EngineOperation Techniques Skill Levels MaintenanceMaintenance Intervals Air Filter Fuel FilterSpark Plug Cooling SystemExhaust System Spark Arrestor ScreenEngine Break-In Carburetor AdjustmentExhaust Port Cleaning High Altitude OperationDrive Shaft Gear HousingLubrication Blade Replacement Troubleshooting Engine Problem Troubleshooting ChartStorage Long Term Storage Over 30 DaysSpecifications ModelWarranty Statements ExceptionsWarranty Statements ECHO, Incorporated