Dixon 18124-106 manual Troubleshooting, Engine WON’T Turn Over

Page 48

TROUBLESHOOTING

1. ENGINE WON’T TURN OVER

Mower blades engaged- - - - - - - - - - - - - - - - - - - disengage blades Parking brake not on- - - - - - - - - - - - - - - - - - engage parking brake Circuit breaker trips- - - - - - - - - - - - - - - - - - - - - - - - -reset breaker Dead battery- - - - - - - - - - - - - - - - - - - - - - - - - - charge or replace Solenoid- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - consult dealer Ignition switch- - - - - - - - - - - - - - - - - - - - - - - - - - - - consult dealer Starter- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - consult dealer

2. ENGINE WILL TURN OVER BUT WON’T START

No fuel- - - - - - - - - - - - - - - refuel and/or clean or replace fuel filters

3. HARD TO START ENGINE

Fuel line clogged- - - - - - - - - - - - - clean fuel line and check fuel filter Faulty fuel pump- - - - - - - - - - - - - - - - - - - - - - - - - - consult dealer

4. ENGINE STARTS BUT CUTS OUT

Water in fuel- - - - - - - - - - - - - - -drain old fuel-replace with new fuel Clogged fuel line- - - - - - - - - - - - - - - - - - - - - - - - - - check fuel filter Fuel tank vent plugged- - - - - - - - - - - - - - - - - - - - - -clean fuel vent Faulty fuel pump- - - - - - - - - - - - - - - - - - - - - - - - - - consult dealer

5. ENGINE OVERHEATED

Air intake screen or fins clogged- - - - - -clean intake screen and fins Oil level too low or too high- - - - - - - - - - - - - - - - - - - -adjust oil level Running engine too slow - - - - - - - - - - - - - - - - - -run engine faster

48

Image 48
Contents Safety Instructions Operator’s Manual Important Read Carefully Table of Contents Safety Safety Alert Symbol General Operation General Operation General Operation Slope Operation Slope Operation Do not Fire Hazards Fire Hazards Children Service Dixon ZTR PRO Series COMMERCIAL/RESIDENTIAL Warranty Policy Specifications Kodiak and Mountain KodiakSeat Adjustment Instructions Controls Control LeversParking Brake To SET Parking BrakeMower Deck CUT Height Lift Lever Blade Drive Circuit BreakerChoke and Throttle Control Levers Operation Instructions Before Operating MowerStarting Instructions Testing of Safety Interlock Systems Parking Brake Switch TestEngine should Stop Mowing with a Mulching Attachment Mowing with a Mulching Attachment Mowing with a Grass Catcher Attachment Mowing with a Grass Catcher Attachment Failure to observe the following instructionsSide Discharge of the Clippings Grass Height & Cutting Suggestions Towing Trailers and Other Attachments To Free Wheel Machine Unlock TransmissionCare and Maintenance Maintenance ScheduleCutter Blade Maintenance Battery EngineTires LubricationBelts Belt TensionChanging the Engine OIL OIL Fill OIL FiltersHydrostatic Transmission Fluid Filter Service Recommended FluidHydrostat Fluid Maintenance Procedure Neutral Adjustment Neutral Spring Adjustment Mower Deck Leveling Procedure Mower Deck Leveling Procedure Cleaning the Mower WarrantyPARTS/SERVICE Electrical SystemsMower Deck Removal Troubleshooting Engine WON’T Turn OverMower Loses Power or Transmission Overheats Standard Service Parts List BladesOWNER’S Information Date OIL ChangedDixon INDUSTRIES, INC

18124-106 specifications

The Dixon 18124-106 is a versatile and robust product designed for a variety of industrial and commercial applications. Renowned for its quality and reliability, this model exemplifies Dixon's commitment to innovation and performance.

One of the main features of the Dixon 18124-106 is its durable construction. It is manufactured from high-quality materials that ensure longevity and resistance to wear and tear. This makes it an ideal choice for environments where exposure to chemicals, extreme temperatures, or physical stress is likely. The design incorporates robust seals and fittings that enhance its overall functionality and performance.

Technologically, the Dixon 18124-106 is equipped with advanced features that improve its efficiency and ease of use. The model includes a user-friendly interface that allows for simple operation, making it accessible to both seasoned professionals and newcomers to the industry. The integration of precision engineering techniques ensures that the product operates smoothly and reliably, minimizing downtime in critical processes.

Another characteristic of the Dixon 18124-106 is its versatility. It is compatible with a wide range of attachments and accessories, enabling users to customize it according to their specific needs. This adaptability makes it suitable for various applications, from fluid transfer to handling gases and other materials. The ability to interchange components allows for increased efficiency and productivity on the job.

Furthermore, the Dixon 18124-106 adheres to industry safety standards, ensuring that it can be used in compliance with regulatory requirements. The model features safety mechanisms that prevent accidental misuse, protecting both the operator and the equipment. This attention to safety is a crucial aspect of Dixon's product design philosophy.

In terms of maintenance, the Dixon 18124-106 is designed for ease of upkeep. Its modular construction allows for straightforward disassembly and cleaning, which is essential for maintaining operational standards in industries such as food processing and pharmaceuticals. Regular maintenance is simplified, enabling users to keep their equipment in prime condition for optimal performance.

Overall, the Dixon 18124-106 stands out in its category, driven by quality engineering, user-centric design, and a commitment to safety and efficiency. Whether in construction, manufacturing, or other industrial fields, this model delivers the performance and reliability professionals depend on.