UNPACKING
CAUTION: Do not remove the data plates from the grate as- sembly. The data plates contain important warranty and safety information.
1.Remove log set assembly from carton.
2.Remove all protective packaging applied to log set for shipment.
3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought appliance.
GENERAL INFORMATION
These vented decorative gas log sets incorporate
These units are remote
A spark ignition system (piezo) allows the gas pilot to be lit without the use of matches or bat- teries and permits operation of the heater during a power outage.
These log sets come with a Floor Media Kit in- cluded. This kit is used to blend the floor and the log set together for a more natural look.
CAUTION:Thisheatercreates warmaircurrents.Thesecurrents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operatingheaterwhereimpurities (such as, but not limited to, to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
WARNING: Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible material.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not instal in fireplace. Call dealer where you bought the appliance for proper type of appliance.
INSTALLATION
WARNING: A qualified ser- vice person must install heater. Follow all local codes.
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creo- sote will ignite if highly heated. A dirtychimneyfluemaycreateand distribute soot within the house. Inspectchimneyfluefordamage. If damaged, repair flue damper before operating appliance.
WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed only in a
LOG SIZING REQUIREMENTS
| MINIMUM FIREBOX SIZE | |||
LOG |
|
| FRONT | REAR |
SIZE | HEIGHT | DEPTH | WIDTH | WIDTH |
18" | 14" | 16" | 30" | 20" |
24" | 18" | 18" | 34" | 24" |
|
|
|
|
|
www.desatech.com | 5 |