  | Lamp Type  | Lamp Orientation  | Maintained Lumens Life [hrs.]  | Input Watts  | Efficacy [lms/w]  | 
  | 
  | ||||
  | 1000W  | Probe Start MH  | Vertical  | 82,000  | 10,000  | 1080  | 102  | 
  | 
  | 
  | |
  | 1000W  | Pulse Start MH  | Horizontal  | 71,500  | 9,000  | 
  | 1080  | 97  | 
  | 
  | 
  | 
  | Vertical  | 96,000  | 15,000  | 1100  | 109  | 
  | 
  | 
  | |||
  | 875W Pulse Start MH  | Horizontal  | 86,000  | 9,000  | 
  | 1100  | 98  | 
  | 
  | 
  | |
  | Vertical  | 80,000  | 20,000  | 940  | 106  | 
  | 
  | 
  | |||
  | 750W Pulse Start MH  | Horizontal  | 76,000  | 12,000  | 940  | 101  | 
  | 
  | 
  | ||
  | Vertical  | 62,000  | 16,000  | 820  | 100  | 
  | 
  | 
  | |||
  | 
  | 
  | Horizontal  | 47,500  | 12,000  | 820  | 83  | 
  | 
  | 
  | |
  | Lamp Type  | Average Input  | Number of  | Operating  | Days/  | Total Annual  | Annual  | % Savings  | |||
  | Watts  | Fixtures 1  | Hours/Day  | Year  | $/KWH | Operating Cost 2  | Savings 3  | ||||
  | 1000W  | Probe Start MH  | 1080  | 150  | 10  | 365  | 0.10  | $59,130  | 
  | $7,665  | 13%  | 
875W Pulse Start MH  | 940  | 150  | 10  | 365  | 0.10  | $51,465  | 
  | ||||
  | 750W Pulse Start MH  | 820  | 150  | 10  | 365  | 0.10  | $44,895  | 
  | $14,235 | 24% | |
NOTES: 1 A medium sized automotive dealership typically has 150 fixtures on site. If your dealership varies from this size, savings can be calculated using the following multiplier: 0.67 [100 fixtures], 1.33 [200 fixtures], 1.67 [250 fixtures]. 2 Total annual cost is the cost of operating 150 fixtures 10 hours per day with a national average energy cost of $0.10 per KWH. Annual Cost = (Input watts)*(# of fixtures)*(operating hours)*(days/year)*(KWH/1000). 3 Annual Savings is the money saved by operating 150 fixtures for 10 hours per day with the listed pulse start lamp over the standard 1000W probe start lamp. Annual Savings = (Total Annual 1000W Probe Start MH cost) - (Total Annual Cost Pulse Start MH).
Beyond efficient light source selection, 
  | 
  | 
  | Average Input  | Number of  | Off Business  | Days/  | 
  | Total Annual  | Dimming  | 
  | 
Lamp Type  | Operating  | $/KWH  | Annual  | % Savings  | ||||||
Watts  | Fixtures 1  | Hours/Day  | Year  | Operating Cost 2  | Savings 3  | |||||
1000W  | Probe Start MH [Full Power]  | 1080  | 150  | 5  | 365  | 0.10  | $29,565  | $11,361 | 38% | |
1000W  | Probe Start MH   | 150  | 5  | 365  | 0.10  | $18,204  | ||||
875W  | Pulse Start MH [Full Power]  | 940  | 150  | 5  | 365  | 0.10  | $25,733  | $9,992 | 39% | |
875w Pulse Start MH   | 575  | 150  | 5  | 365  | 0.10  | $15,741  | ||||
750W  | Pulse Start MH [Full Power]  | 820  | 150  | 5  | 365  | 0.10  | $22,448  | $8,815 | 39% | |
750W  | Pulse Start MH   | 498  | 150  | 5  | 365  | 0.10  | $13,633  | |||
NOTES: 1 A medium sized automotive dealership typically has 150 fixtures on site. If your dealership varies from this size, savings can be calculated using the following multiplier: 0.67 [100 fixtures], 1.33 [200 fixtures], 1.67 [250 fixtures]. 2 Total annual cost is the cost of operating 150 fixtures 5 hours per day with a national average energy cost of $0.10 per KWH. Annual Cost = (Input watts)*(# of fixtures)*(operating hours)*(days/year)*(KWH/1000). 3 Annual Savings is the money saved by operating 150 fixtures in dimmed operation for 5 hours per day. Annual Savings = (Total Annual [Full Power] Cost) - (Total Annual 
Alternating Fixture Switching