HIGH COMPETITION SITE LIGHTING

General Merchandise

Front Row

POLE FIXTURE COMBINATION ORDERING LOGIC

HIGH COMPETITION DISPLAY

When your automotive dealership lot is neighbored by well illuminated dealerships or service stations high competition lighting levels are recommended. Create a front row feature display along the roadway with primary traffic flow. To prevent obstructing the view of displayed vehicles, mount poles at grade [25' pole/fixture mounting height]. The remaining areas of the dealership displaying vehicles are considered general merchandise areas. To protect merchandise, mount poles on a 2.5' concrete base [25' pole, 27 1/2' fixture mounting height].

 

 

 

 

 

 

 

High

Horizontal

 

 

 

 

 

 

 

Maintained

Uniformity

Area to Illuminate

 

 

 

 

Levels [fc]

[Max.Min.]

Parking and Circulation [Non-Merchandising Area]

10

10:1

General Merchandise [Main Automotive Display Lot]

50

5:1

Featured Displays [Front Row and Display Stands]

 

75

3:1

 

Arrow denotes optical orientation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Footcandles [fc]

 

 

 

 

 

 

 

80

52

34

22

14

9

6

4

 

1000W MH FLAT GLASS ENHANCED FRONT ROW DISPLAY

Areas with extremely high visual competition could use enhanced illumination levels between 75-100 FC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Height [ft.]

25

Spacing [ft.]

40

Maintained Average FC

94.5

Uniformity

1.22

Distribution

Fixture Configuration

Product Family 1

80 MPH

90 MPH

100 MPH 2

Automotive Front Row [AF]

2 @ 180°

Talon [TLL]

TLL21KMFF25XX 3

TLL21KMFF25XX 3

TLL21KMFF25XX0 4

 

 

Galleria Square [GSM]

GSM21KMFF25XX 3

GSM21KMFF25XX 3

GSM21KMFF25XX0 4

 

 

Galleria Round [GRM]

GRM21KMFF25XX 3

GRM21KMFF25XX 3

GRM21KMFF25XX 3

 

 

CLM

CLM21KMFF25XX 3

CLM21KMFF25XX 3

CLM21KMFF25XX0 4

NOTES: 1 Pole fixture combination includes pole, fixtures, lamp, and mounting hardware. Fixture supplied with 5-Tap [120/208/240/277/480V] ballast wired 480V. 2 0 noted where needed to designate a heavier gauge pole. 3 Combination supplied with SSS5A25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4]. 4 Combination supplied with SSS5M25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4].

1000W MH FLAT GLASS ENHANCED MERCHANDISE DISPLAY

Areas with extremely high visual competition could use enhanced illumination levels between 50-60 FC.

 

 

 

 

Mounting Height [ft.]

 

27.5

 

 

 

 

Spacing [ft.]

 

55

 

 

 

 

Maintained Average FC

54.6

 

 

 

 

Uniformity

 

1.15

POLE FIXTURE COMBINATION ORDERING LOGIC

 

 

 

 

 

 

Distribution

Fixture Configuration

Product Family 1

80 MPH

90 MPH

100 MPH

 

 

Area Round [AR]

3 @ 90°

Talon [TLL]

TLL31KMRF25XX 2

TLL31KMRF25XX 2

TLL31KMRF25XX 2

 

 

 

Galleria Square [GSM]

GSM31KMRF25XX 2

GSM31KMRF25XX 2

GSM31KMRF25XX 2

 

 

Galleria Round [GRM]

GRM31KMRF25XX 2

GRM31KMRF25XX 2

GRM31KMRF25XX 2

 

 

CLM

CLM31KMRF25XX 2

CLM31KMRF25XX 2

CLM31KMRF25XX 2

 

NOTES: 1 Pole fixture combination includes pole, fixtures, lamp, and mounting hardware. Fixture supplied with 5-Tap [120/208/240/277/480V] ballast wired 480V. 2 Combination supplied with SSS5M25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4].

Image 9
Contents Automotive Automotive Design Guide Table of ContentsLeading the Lighting Industry Site Showroom ServiceOutdoor Site Lighting Consider Your LocationNeighboring Development Iesna Competition Level Consider Your Image Outdoor Site Lighting That Heightens Consumer AwarenessStandard Architectural Finishes Optional Striped Reveal Colors Galleria OnlyLumen Output Over Time Consider Your PocketbookOutput Lumen Hours of Operation 4000 hours ~ 1 year$/KWH Flexibility and Versatility Feature Display LightingI D E D S H I E L D Area to Illuminate Maintained Uniformity Levels fc Max./MinHigh Competition Display High Competition Site Lighting1000W MH Flat Glass Enhanced Front ROW Display 1000W MH Flat Glass Enhanced Merchandise DisplayEnhanced 1000W MH Flat Glass Energy Saving Dimming 1000W MH Flat Glass Front ROW Display750W MH Flat Glass Front ROW Display 1000W MH Flat Glass General Merchandise Display 750W MH Flat Glass General Merchandise Display1000W MH Flat Glass Energy Saving Dimming Medium Competition Display Medium Competition Site LightingTLL21KMRF25XX TLL21KMRF25XX0 LOW Competition Display LOW Competition Site Lighting1000W MH Flat Glass General Merchandise Display Showroom Lighting Inspiration and FunctionalityCRI Intimate InvitingPortfolio MD6 Halo Stasis Halo ConnetixTypical Metal Halide Service BAY Service Department LightingProductivity Leads to Profitability Lumark Benchmark Lumark Steeler Lumark EnterpriseLamp Type Input Number Operating Days Typical Fluorescent Service BAY$105 13% $396 50%Canada