Chromalox SDRA Wiring, SET-UP and Operation, Cord Preparation for Chromalox Portable Heaters, Cfm

Page 2

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

1.Read all instructions before using this heater.

2.This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9m) from the front of the heater and keep them away from the sides and rear.

3.Extreme caution is necessary when any heater is used by or near children or handicapped individuals and whenever the heater is left operating and unattended.

4.Always disconnect heater when not in use.

5.Do not operate any heater with a damaged cable or plug or after the heater malfunctions, has been dropped or damaged in any manner. Return heater to authorized service facility for examination, elec- trical or mechanical adjustments, or repair.

6.Do not use outdoors.

7.This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.

8.Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic area and where it will not be tripped over.

9.To disconnect heater, turn thermostat off, then remove plug from outlet.

10.Connect to properly grounded outlets only.

11.Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire or dam- age the heater.

12.To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where opening may become blocked.

13.A heater has hot and arcing or sparking parts inside.Do not use it in areas where gasoline, paint, flammable liquids are used or stored.

14.Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.

15.This heater is not intended for use with an extension cord.

16.SAVE THESE INSTRUCTIONS.

WIRING

ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be effectively grounded in accordance with the National Electrical Code, NFPA 70.

1.Use heater only on the voltage and frequency specified on the nameplate.

2.All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person.

3.Branch circuit wire for connection to heater must be at least 90˚C wire.

4.The top access panel is secured by 4 screws that must be loosened to gain access.

Table A

5.A ground terminal is provided near the power terminal board. The ground wire should be connected before other connections are made.

6.Refer to Table A for proper size “SO” grade of cable.

7.A proper strain relief must be used with “SO” grade cable.

8.Dragon heaters are factory pre-wired for 3-phase delta operation. Some units can be converted to single phase operation by chang- ing the wiring. The appropriate wiring diagram is also located on the back of the wiring compartment cover.

Cord Preparation for Chromalox Portable Heaters

1.Determine the gage and number of conductors from the tabulation below using amps and phase from the heater nameplate. It is not recommended that cord exceed 50 feet in length.

Model Number

Volts

kW

Phase

Amps

Min Wire Size

SDRA-30-43

480

30

3

37.2

6 Ga

SDRA-30-63

600

30

3

30.0

8 Ga

SDRA-48-43

480

48

3

58.9

4 Ga

SDRA-48-63

600

48

3

47.3

4 Ga

SDRA-60-43

480

60

3

73.3

2 Ga

SDRA-60-63

600

60

3

58.9

4 Ga

SET-UP AND OPERATION

The SDRA SuperDragon is designed to be used with 20” diameter flexible duct. A feature of the heater is that the fan speed can be easily adjusted from 1500 to 2300rpm, (SDRA heaters are shipped from the factory with the fan speed set at 1800 rpm). The maximum external static load for the blower is .38” H2O, regardless of the fan speed selected. The outlet temperature is controlled by a built-in thermostat- ic control; the maximum outlet temperature is a function of the kW rat- ing and the amount of air (cfm) flowing through the heater. The addi- tion of flexible duct will provide additional static load, resulting in a lower cfm, the lower air flow will reaise maximum outlet temperature until the static load reaches .38”H2O. Exceeding the maximum static load will result in the tripping of the overtemperature control. The per- formance range of the SDRA units is as shown in table B.

The motor and fan have variable pitch pulleys for changing the air flow and the ΔT. Graphs 1, 2 and 3 provide the performance data for

Table B

 

 

 

Δ T

Max.

ΔT at Max.

kW

Fan RPM

CFM

No Load

Static Load

Static Load

30

1800

2200

42˚F

.38” H O

86˚F

 

 

 

 

2

 

48

1800

2200

68˚F

.38” H O

144˚F

 

 

 

 

2

 

60

1800

2200

88˚F

.38” H O

170˚F

 

 

 

 

2

 

each size heater at the recommended minimum, medium and maxi- mum fan speeds. The curves end at the point where the .38” H2O stat- ic load has been reached. The temperature rise is based on using Chromalox 20” diameter FX-20 flexible duct. The performance curves were determined by actual testing; therefore using flexible duct not supplied by Chromalox may vary the results. The introduction of bends in the ducting will add static load equivalent to adding 15 feet of duct length for each 90˚ bend and 25 feet of duct length for each 180˚ bend.

2

Image 2
Contents BTU Specifications Table ModelGeneral Supersedes PF499-1Cord Preparation for Chromalox Portable Heaters WiringSET-UP and Operation CFMWiring cont’d AccessoriesFan FAN Speed AdjustmentsChanging the Pitch Diameter of the Sheaves RPMWiring Diagrams Sdra 48kW, 480V, 3PHElement Assembly 48kW Parts LocationParts Common to ALL Units MaintenanceRenewal Parts Identification DescriptionLimited Warranty