Chauvet 460-LED user manual Run Mode Settings

Page 17

Operation

Lockout 1. Select SETTINGS > PERFORM > KEY LOCK.

2.To choose activate the password function on the control panel, press <ENTER>.

a.Select YES or NO.

b.Press <ENTER>.

Homepage Setting 1. Select SETTINGS > PERFORM > HOMEPAGE.

2.To choose what to show on the home screen on the control panel, press <ENTER>.

a.Select DMX, to show only the DMX Channel or NAME+DMX to display what is programmed via the CONTENT level.

b.Press <ENTER>.

Limit Pan/Tilt Range 1. Select SETTINGS > RANGE.

2.To set the start and end points of the pan and tilt ranges, press <ENTER>.

a.Select P.START and set the pan starting point between 000~255.

b.Press <ENTER>.

c.Select P.END and set the pan ending point between 000~255.

d.Press <ENTER>.

e.Select T.START and set the tilt starting point between 000~255.

f.Press <ENTER>.

g.Select T.END and set the tilt ending point between 000~255.

h.Press <ENTER>.

Product Defaulting 1. Select SETTINGS > DEFAULT.

2.To reset the product to original factory settings, press <ENTER>.

a.Select YES or NO.

b.Press <ENTER>.

Program Send 1. Select SETTINGS > SEND.

2.To send all settings in the Q-Spot™ 460 LED to other Q-Spot™ 460 LED products connected via Master/Slave, press <ENTER>.

a.Select YES or NO.

b.Press <ENTER>.

Run Mode Settings

Run Mode 1. Select RUNMODE > RUN.

2.To enable DMX mode:

a.Select DMX512, press <ENTER>.

3.To enable Auto modes:

a.Select AUTO1 or AUTO2, press <ENTER>.

4.To enable Sound-Active modes:

a.Select SOUND1 or SOUND2, press <ENTER>.

5.To enable Custom Program mode:

a.Select CUSTOM, press <ENTER>.

6.To enable Testing mode:

a.Select TEST, press <ENTER>.

7.To assign the product to Slave mode:

a.Select SLAVE, press <ENTER>.

Q-Spot™ 460-LED User Manual Rev. 5

13

Image 17
Contents Page Author Date Editor Couppe 14/13 Diaz Edition NotesCopyright 2013 CHAUVET. All rights reserved Table of Contents Technical Specifications Before You Begin What Is IncludedClaims Manual Conventions Symbols Product at a Glance Use on Dimmer Safety NotesIntroduction Product Description FeaturesIn/Out Fuse Power Gobo Access Panel Control Handles Omega BracketsProduct Dimensions AC Power SetupAC Plug Power Linking Fuse Replacement Connection Wire U.S Wire Europe Screw ColorDMX Modes Master/Slave Connectivity DMX LinkingGobo Wheels Color Wheel Gobo Replacement Orientation MountingControl Panel Description Control Options OperationProgramming Navigation Buttons Button FunctionProduct Settings Run Mode Settings Program Send 1. Select Runmode Send Manual SettingsCustom Programming 1. Select Runmode Edit Step Service Menu Selects the 11-channel DMX mode Selects the 14-channel DMX modeDefines the move-in black delay Save the last look when DMX signal is lost255 000~01~49 000~255DMX Values Channel Function Value Percent/SettingFocus 000 ó DMX Values Technical Information Product Maintenance ReturnsTechnical Specifications World Headquarters United Kingdom and Ireland Contact Us