5.TECHNICAL INFORMATION
Fogger Maintenance
Storage
Do not allow the fog machine to become contaminated. After every 40 hours of continuous operation, CHAUVET® recommends running a cleaning solution composed of 80% distilled water and 20% distilled vinegar through the system to prevent the accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows:
1.Empty all fog liquid from the machine.
2.Add cleaning solution to tank.
3.Plug unit in and allow it to warm up.
4.Run the unit in a
5.Cleaning is now complete. Refill with fog liquid. Run the machine briefly to clear any cleaning solution from the pump and heater.
Before storing this product, run distilled water (not tap water) through the system as described in the cleaning method above. This will help to avoid any particles condensing inside the pump or heater.
It is strongly recommended to
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Arena™ 2100 Flex. Make sure you use FCQ regularly to increase the life of your fogger.
Arena™ 2100 Flex User Manual (Rev. 7) | Page 11 of 13 |