Linn AKURATE Loudspeaker System owner manual English Akurate

Page 17

English AKURATE 221

Description and available settings for parameters

Default settings are shown in grey.

 

PARAMETER

SYMBOL

0

1

2

3

4

5

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External high pass

 

 

 

 

 

 

 

 

 

 

 

 

frequency*

 

 

 

 

 

 

 

 

 

 

 

 

Increasing the setting

 

 

10

50

75

100

115

135

160

190

235

 

reduces the bass

 

 

 

content sent to the

 

 

 

 

 

 

 

 

 

 

 

 

external speakers. (Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal high pass

 

 

 

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

Increasing the setting

 

 

18

22

25

30

34

40

 

 

 

 

raises the lowest

 

 

 

 

 

 

frequency produced

 

 

 

 

 

 

 

 

 

 

 

 

by the unit. (Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal low pass

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency**

 

 

 

 

 

FILTERING

 

 

 

 

 

 

Reducing the setting

 

 

55

85

130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lowers the highest

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency produced by

 

 

 

 

 

 

 

 

 

 

 

 

the unit. (Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Only for use when the AKURATE 221 speaker is connected to a power amplifier (see Connecting section in this chapter).

** If you are using the AKURATE 221 speaker with a Linn System Controller or other AV processor, set to 4 (No filtering).

PARAMETER

Coarse gain Every one step increase in the setting raises the gain (volume) of the speaker by

5 decibels. Every one step decrease in the setting lowers the gain (volume) of the speaker by

5 decibels. (dB)

Fine gain Every one step increase in the setting raises the gain (volume) of the loudspeaker by

1 decibel. (dB)

Bass equalisation Every one step increase in the setting applies an additional 3 dBs at 30 Hz and below. (dB@30 Hz)

Time out

Length of time before unit will go into standby after audio input ceases. (mins)

SYMBOL 0 1 2 3 4 5 6 7 8 9

-15 -10 -5 0 +5 +10 +15

0 +1 +2 +3 +4

0

+3

+6

ALWAYSON

5

10

20

 

 

 

 

 

AKURATE Loudspeaker System

Owner’s Manual

12

 

Image 17
Contents Akurate Loudspeaker System Important Safety Information English Important Safety InformationFuse replacement English Important Safety InformationMains plug replacement CE Declaration of ConformityCopyright and Acknowledgements English Copyright and AcknowledgementsContents Akurate system IntroductionIntroduction English English Introduction FeaturesAkurate 242, 225 Entire SystemAkurate 242, 225 CleaningUnpacking Akurate 242, 225 and 212 EnglishPositioning English Akurate 242, 225Positioning and levelling Levelling General ConnectingBi-wiring or bi-amping Single-wiring Tri-wiring or tri-ampingImportant notes on using the link strips Quad-amping and beyondImportant Notes on Aktiv Systems Aktiv operationVoltage selection Akurate 221 EnglishPositioning Fabric grilleAkurate 221 ONE Connecting to another Akurate 221 speakerOperation Adjusting the parametersOperating modes ParametersEnglish Akurate Description and available settings for parametersTechnical Specifications English Technical SpecificationsEnglish Guarantee and Service Guarantee and Service